SMPTE RP 14-1997 Plotting Data from Sensitometric Strips Exposed on Type Ib (Intensity Scale) Sensitometers《暴露于Ib型(强度标)感光计的感光片显示的绘图数据》.pdf
《SMPTE RP 14-1997 Plotting Data from Sensitometric Strips Exposed on Type Ib (Intensity Scale) Sensitometers《暴露于Ib型(强度标)感光计的感光片显示的绘图数据》.pdf》由会员分享,可在线阅读,更多相关《SMPTE RP 14-1997 Plotting Data from Sensitometric Strips Exposed on Type Ib (Intensity Scale) Sensitometers《暴露于Ib型(强度标)感光计的感光片显示的绘图数据》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 STD-SMPTE RP L4-ENGL 3977 8357403 0002730 460 SMPTE RECOMMENDED PRACTICE Plotting Data from Sensitometric RP 14-1 997 Revision of RP 14-1988 Strips Exposed on Type Ib (Intensity Scale) Sensitometers 1 Scope The purpose of this practice is to specify the relation- ship of the spacings of the exposur
2、e scale (horizontal coordinate) of graph paper on which sensitometric data are plotted and the corresponding increments of the logarithm of exposure in the sensitometer when the exposure modulator is a step tablet. 2 Normative references The following standards contain provisions which, through refe
3、rence in this text, constitute provisions of this practice. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this practice are encouraged to investigate the possibility of applying the most recent edition of the
4、standards indicated below. ANSI/ISO 5-2-1 995, ANSVNAPM IT2.19-1995, Photography - Density Measurements - Part 2: Geometric Conditions for Transmission Density ANSI/ISO 5-3-1995, ANSI/NAPM IT2.18-1996, Photography - Density Measurements - Part 3: Spectral Conditions 3 Exposure method 3.1 In a type I
5、b (intensity scale) sensitometer, the most common method of modulating the illumination falling upon the sample employs a step tablet. The exposure is made with the emul- sion of the sample in contact with the modulator except for a thin, transparent acetate cover which protects the modulator agains
6、t abrasion and foreign matter. The opening and closing of a shutter admits light for the required period of time. Step tablets may be cast with gelatin Page 1 of 3 pages containing dyes or colloidal carbon or, alterna- tively, may be produced photographically by suitable exposure and development of
7、film or plates. 3.2 With a step tablet as the exposure modulator, the illumination reaching the sample is dependent upon the transmittance of the various steps of the modulator. This assumes uniformity of illumi- nation. Density, being the common logarithm of the reciprocal of the transmittance, is
8、a more convenient method for specifying the light- stopping power of the segments of the modulator. Density may be measured with a densitometer calibrated in reference to ANSI/ISO 5-2, ANSI/NAPM IT2.19, and ANSI/ISO 5-3, ANSVNAPM IT2.18. 3.3 The Ib (intensity scale) sensitometer exposure modulator s
9、hould typically have step- to-step increments of 0.1 5 diffuse transmission visual density; however, other increments can be used for specific needs. As modulators vary somewhat from this 0.15 increment, it may be necessary to adjust the step reference points on the exposure axis (horizontal coordin
10、ate) of the sensitometric graph paper to represent the actual densities of each step in the tablet. (Single step departures of the order of 0.01 5, or less, from the ideal 0.15 density increment, when known, would not be considered signifi- cant. However, cumulative errors, especially those which oc
11、cur in the same direction, are significant and can lead to erroneous results (see figure 1). 4 Method of correction 4.1 The steps of the exposure modulator shall be measured with a densitometer reading in dif- fuse transmission visual density, specified in Copyright O 1997 by the SOCIETY OF MOTION P
12、ICTURE AND TELEVISION ENGINEERS 595 W. Hartsdale Ave., White Plains, NY 10607 (914)761-1100 Approved January 22,1997 RP 14-1 997 1.8 i .6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 o .o 3.0 2.8 2.6 2.4 2.2 2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Dm NOTES 1 - - -x- - -x = curve showing sample densities versus m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SMPTERP141997PLOTTINGDATAFROMSENSITOMETRICSTRIPSEXPOSEDONTYPEIBINTENSITYSCALESENSITOMETERS 暴露 IB 强度 感光

链接地址:http://www.mydoc123.com/p-1046376.html