SANS 61000-3-2-2009 Electromagnetic compatibility (EMC) Part 3-2 Limits - Limits for harmonic current emissions (equipment input current = 16 A per phase)《电磁兼容性(EMC) 第3-2部分 限值 谐波电流.pdf
《SANS 61000-3-2-2009 Electromagnetic compatibility (EMC) Part 3-2 Limits - Limits for harmonic current emissions (equipment input current = 16 A per phase)《电磁兼容性(EMC) 第3-2部分 限值 谐波电流.pdf》由会员分享,可在线阅读,更多相关《SANS 61000-3-2-2009 Electromagnetic compatibility (EMC) Part 3-2 Limits - Limits for harmonic current emissions (equipment input current = 16 A per phase)《电磁兼容性(EMC) 第3-2部分 限值 谐波电流.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22961-0 SANS 61000-3-2:2009Edition 3.2IEC 61000-3-2:2009 Edition 3.2 SOUTH AFRICAN NATIONAL STANDARD Electromagnetic compatibility (EMC) P
4、art 3-2: Limits Limits for harmonic current emissions (equipment input current 16 A per phase) This national standard is the identical implementation of IEC 61000-3-2:2009, and is adopted with the permission of the International Electrotechnical Commission. Published by SABS Standards Division 1 Dr
5、Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 61000-3-2:2009 Edition 3.2 IEC 61000-3-2:2009 Edition 3.2 Table of changes Change No. Date Scope IEC amdt 1 2008 Amended to add definitions for the repeatability, reproducibility
6、and variability of results of measurement, and provide additional test conditions for the measurement of harmonic currents associated with equipment such as vacuum cleaners and IT equipment. IEC amdt 2 2009 Amended to add two normative references, a definition for total harmonic distortion and a sim
7、plified test method for equipment that undergoes minor changes or updates, and to replace and add a new figure 2 and text relating to measurement procedure, limits for Class C equipment, and test conditions for audio amplifiers, lamps and washing machines. National foreword This South African standa
8、rd was approved by National Committee SABS TC 73, Electromagnetic compatibility, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in June 2009. This SANS document supersedes SANS 61000-3-2:2006 (editio
9、n 3 as modified by IEC amdt 1:2008). IEC 61000-3-2Edition 3.2 2009-04INTERNATIONAL STANDARD NORME INTERNATIONALEElectromagnetic compatibility (EMC) Part 3-2: Limits Limits for harmonic current emissions (equipment input current 16 A per phase) Compatibilit lectromagntique (CEM) Partie 3-2: Limites L
10、imites pour les missions de courant harmonique (courant appel par les appareils 16 A par phase) INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE CGICS 33.100.10 PRICE CODECODE PRIXISBN 2-8318-1034-6 Registered trademark of the International Electrotechnical Commis
11、sion Marque dpose de la Commission Electrotechnique Internationale SANS 61000-3-2:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS . 2 61000-3-2 IEC:2005+A1:2008 +A2:2009 CONTENTS FOREWORD.4 INTRODUCTION.6 1 Scope.7 2 Normative references7
12、3 Definitions 8 4 General 12 5 Classification of equipment .12 6 General requirements .13 6.1 Control methods 13 6.2 Harmonic current measurement .14 6.3 Equipment in a rack or case.16 7 Harmonic current limits .17 7.1 Limits for Class A equipment .19 7.2 Limits for Class B equipment .19 7.3 Limits
13、for Class C equipment .19 7.4 Limits for Class D equipment .20 Annex A (normative) Measurement circuit and supply source.22 A.1 Test circuit.22 A.2 Supply source 22 Annex B (normative) Requirements for measurement equipment 25 Annex C (normative) Type test conditions.26 C.1 General26 C.2 Test condit
14、ions for television (TV) receivers .26 C.3 Test conditions for audio amplifiers 27 C.4 Test conditions for video-cassette recorders.28 C.5 Test conditions for lighting equipment 28 C.6 Test conditions for independent and built-in incandescent lamp dimmers29 C.7 Test conditions for vacuum cleaners 29
15、 C.8 Test conditions for washing machines 29 C.9 Test conditions for microwave ovens 29 C.10 Test conditions for information technology equipment (ITE) 30 C.11 Test conditions for induction hobs 31 C.12 Test conditions for air conditioners.31 C.13 Test conditions for kitchen machines as defined in I
16、EC 60335-2-14 31 C.14 Test conditions for arc welding equipment which is not professional equipment 32 SANS 61000-3-2:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .61000-3-2 IEC:2005+A1:2008 3 +A2:2009 Figure 1 Flowchart for determining
17、 conformity 18 Figure 2 Illustration of the relative phase angle and current parameters described in 7.3 b) 19 Figure A.1 Measurement circuit for single-phase equipment23 Figure A.2 Measurement circuit for three-phase equipment.24 Table 1 Limits for Class A equipment .20 Table 2 Limits for Class C e
18、quipment .21 Table 3 Limits for Class D equipment .21 Table 4 Test observation period .21 Table C.1 Conventional load for arc welding equipment tests32 SANS 61000-3-2:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS . 4 61000-3-2 IEC:2005+A
19、1:2008 +A2:2009 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ ELECTROMAGNETIC COMPATIBILITY (EMC) Part 3-2: Limits Limits for harmonic current emissions (equipment input current 16 A per phase) FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organization for standardizat
20、ion comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC publishes Internatio
21、nal Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with may participate in t
22、his preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agreement between the tw
23、o organizations. 2) The formal decisions or agreements of IEC on technical matters express, as nearly as possible, an international consensus of opinion on the relevant subjects since each technical committee has representation from all interested IEC National Committees. 3) IEC Publications have th
24、e form of recommendations for international use and are accepted by IEC National Committees in that sense. While all reasonable efforts are made to ensure that the technical content of IEC Publications is accurate, IEC cannot be held responsible for the way in which they are used or for any misinter
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS61000322009ELECTROMAGNETICCOMPATIBILITYEMCPART32LIMITSLIMITSFORHARMONICCURRENTEMISSIONSEQUIPMENTINPUTCURRENT16APERPHASE

链接地址:http://www.mydoc123.com/p-1031485.html