SANS 60947-7-3-2009 Low-voltage switchgear and controlgear Part 7-3 Ancillary equipment - Safety requirements for fuse terminal blocks《低压开关设备及控制设备 第7-3部分 辅助设备 火线接线板安全要求》.pdf
《SANS 60947-7-3-2009 Low-voltage switchgear and controlgear Part 7-3 Ancillary equipment - Safety requirements for fuse terminal blocks《低压开关设备及控制设备 第7-3部分 辅助设备 火线接线板安全要求》.pdf》由会员分享,可在线阅读,更多相关《SANS 60947-7-3-2009 Low-voltage switchgear and controlgear Part 7-3 Ancillary equipment - Safety requirements for fuse terminal blocks《低压开关设备及控制设备 第7-3部分 辅助设备 火线接线板安全要求》.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22821-7 SANS 60947-7-3:2009Edition 2IEC 60947-7-3:2009Edition 2SOUTH AFRICAN NATIONAL STANDARD Low-voltage switchgear and controlgear Part
4、 7-3: Ancillary equipment Safety requirements for fuse terminal blocks This national standard is the identical implementation of IEC 60947-7-3:2009 and is adopted with the permission of the International Electrotechnical Commission. WARNING Can only be used in conjunction with SANS 60947-1 and SANS
5、60947-7-1.Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 60947-7-3:2009 Edition 2 IEC 60947-7-3:2009 Edition 2 Table of changes Change No. Date Scope National foreword This South Afric
6、an standard was approved by National Committee SABS SC 67B, Electricity distribution systems and components Low-voltage switchgear, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in July 2009. This S
7、ANS document supersedes SANS 60947-7-3:2003 (edition 1 as modified by IEC corr.1:2003). IEC 60947-7-3Edition 2.0 2009-04INTERNATIONAL STANDARD NORME INTERNATIONALELow-voltage switchgear and controlgear Part 7-3: Ancillary equipment Safety requirements for fuse terminal blocks Appareillage basse tens
8、ion Partie 7-3: Matriels accessoires Exigences de scurit pour les blocs de jonction fusible INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE WICS 29.120.99; 29.130.20 PRICE CODECODE PRIXISBN 2-8318-1038-7 Registered trademark of the International Electrotechnical
9、Commission Marque dpose de la Commission Electrotechnique Internationale SANS 60947-7-3:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS . 2 60947-7-3 IEC:2009 CONTENTS FOREWORD.4 INTRODUCTION.6 1 General 7 1.1 Scope7 1.2 Normative referenc
10、es 7 2 Definitions 8 3 Classification9 4 Characteristics .9 4.1 Fuse-links .9 4.2 Rated power dissipation value.9 4.2.1 Overload and short-circuit protection (PV)9 4.2.2 Exclusive short-circuit protection (PVK)9 4.3 Rated and limiting values 9 4.3.1 Rated voltages 9 4.3.2 Void.9 4.3.3 Standard cross
11、-sections 9 4.3.4 Rated cross-section.9 4.3.5 Rated connecting capacity.9 4.3.6 Working voltage.10 5 Product information 10 5.1 Marking .10 5.2 Additional information10 5.3 Marking on the packing unit.10 6 Normal service, mounting and transport conditions.11 6.1.1 Ambient temperature .11 7 Construct
12、ional and performance requirements11 7.1 Constructional requirements11 7.1.1 Clamping units 11 7.1.2 Mounting .11 7.1.3 Clearances and creepage distances 11 7.1.4 Terminal identification and marking .12 7.1.5 Void.12 7.1.6 Rated cross-section and rated connecting capacity .12 7.1.7 Void.12 7.1.8 Act
13、uating conditions 12 7.2 Performance requirements 12 7.2.1 Mechanical requirements during actuation.12 7.2.2 Electrical requirements12 7.2.3 Thermal requirements13 7.3 Electromagnetic compatibility (EMC) .13 8 Tests13 8.1 Kinds of test 13 8.2 General .13 8.3 Verification of mechanical characteristic
14、s 13 8.3.1 General .13 8.3.2 Attachment of the fuse terminal block on its support14 SANS 60947-7-3:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .60947-7-3 IEC:2009 3 8.3.3 Mechanical properties of clamping units of a fuse terminal block
15、 .14 8.3.4 Compatibility between fuse terminal blocks and the fuse-link.14 8.3.5 Mechanical strength of the connection between the terminal block base and the fuse-carrier15 8.4 Verification of electrical characteristics15 8.4.1 General .15 8.4.2 Void.16 8.4.3 Dielectric tests.16 8.4.4 Contact resis
16、tance.17 8.4.5 Temperature rise of clamping units18 8.4.6 Void.18 8.4.7 Ageing test (for screwless-type fuse terminal blocks only) .18 8.5 Verification of thermal characteristics19 8.5.1 General .19 8.5.2 Rated power dissipation 20 8.5.3 Durability.24 8.5.4 Needle flame test 24 8.6 Verification of E
17、MC characteristics 26 Annex A (normative) Gauges .27 Annex B (informative) Power dissipation values PVand PVK28 Annex C (normative) Order of tests and number of specimens.36 Bibliography37 Figure 1 Test arrangement for the verification of the contact resistance.17 Figure 2 Test arrangement for separ
18、ate arrangement 20 Figure 3 Test arrangement for compound arrangement21 Figure 4 Test arrangement for compound arrangement of short-circuit protection 22 Figure 5 Test arrangement for the needle flame test 25 Figure 6 Point of test flame contact (view from the layer placed below the fuse terminal bl
19、ock)25 Figure A.1 Outline of the gauges27 Figure B.1 Derating curve in the case of exclusive short-circuit protection for a separate arrangement.30 Figure B.2 Derating curve in the case of exclusive short-circuit protection for a compound arrangement 31 Figure B.3 Derating curve in the case of overl
20、oad and short-circuit protection for a separate arrangement.33 Figure B.4 Derating curve in the case of overload and short-circuit protection for a compound arrangement 34 Table 1 Test forces 14 Table 2 Dummy fuse-links23 Table A.1 Dimensions and materials for gauges for fuse-links according to IEC
21、60127-2 .27 Table B.1 Results of derating curves in the case of exclusive short-circuit protection.32 Table B.2 Results of derating curves in case of overload and short-circuit protection35 Table C.1 Order of tests and number of specimens36 SANS 60947-7-3:2009This s tandard may only be used and prin
22、ted by approved subscription and freemailing clients of the SABS . 4 60947-7-3 IEC:2009 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR Part 7-3: Ancillary equipment Safety requirements for fuse terminal blocks FOREWORD 1) The International Electrotechnical Commiss
23、ion (IEC) is a worldwide organization for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in
24、addition to other activities, IEC publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee int
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS60947732009LOWVOLTAGESWITCHGEARANDCONTROLGEARPART73ANCILLARYEQUIPMENTSAFETYREQUIREMENTSFORFUSETERMINALBLOCKS

链接地址:http://www.mydoc123.com/p-1031463.html