SANS 6072-2009 Coking properties of coal (Ruhr dilatometer test)《煤的成焦性(鲁尔膨胀计试验)》.pdf
《SANS 6072-2009 Coking properties of coal (Ruhr dilatometer test)《煤的成焦性(鲁尔膨胀计试验)》.pdf》由会员分享,可在线阅读,更多相关《SANS 6072-2009 Coking properties of coal (Ruhr dilatometer test)《煤的成焦性(鲁尔膨胀计试验)》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22336-6 SANS 6072:2009 Edition 2SOUTH AFRICAN NATIONAL STANDARD Coking properties of coal (Ruhr dilatometer test) Published by SABS Standa
4、rds Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001 Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 6072:2009 Edition 2 Table of changes Change No. Date Sco
5、pe Foreword This South African standard was approved by National Committee SABS SC 27B, Solid mineral fuels Test methods, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This document was published in April 2009. This document supers
6、edes SABS SM 6072:1984 (edition 1). This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 6072:2009 Edition 2 1 Coking properties of coal (Ruhr dilatometer test) 1 Scope This standard specifies a method for the determination of the coking proper
7、ties of coal by using the Ruhr dilatometer. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any ame
8、ndments) applies. Information on currently valid national and international standards can be obtained from the SABS Standards Division. SANS 18283, Hard coal and coke Manual sampling. 3 Definitions 3.1 repeatability difference between the results of duplicate determinations, carried out at different
9、 times in the same laboratory by the same operator using the same furnace on the same laboratory sample 3.2 reproducibility difference between the means of the results of duplicate determinations, carried out by two different operators using different apparatus on test portions taken from the same g
10、ross sample following reduction to pass a test sieve of aperture size not exceeding 4,0 mm 4 Principle Coal passing a 150 m test sieve is formed under pressure into a pencil. The pencil of coal is inserted into a precisely calibrated narrow tube, topped by a calibrated steel rod (piston) which slide
11、s in the bore of the tube, and the whole is heated at a constant and precise rate. The displacement of the piston is automatically and continuously recorded as a function of the temperature, and a curve, of the type shown in figure 1, is produced from which the dilatometric parameters are determined
12、. NOTE 1 The Ruhr dilatometer test is a variation of the Audibert-Arnu dilatometer test described in ISO 349. If the apparatus used is not equipped with an automatic temperature controller and a device for the automatic registration of the curve, the recommendations of ISO 349 concerning equipment t
13、o be used for the accurate observation of dilatometer piston displacement, the measurement of temperature, control and adjustment of the heating rate, and the recording, calculation and plotting of results should be observed. NOTE 2 The principal factors that can influence the accuracy of the result
14、s are the following: a) Deterioration of the coal as a result of incorrect storage or faulty drying. b) Deviation from the tolerances of This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 6072:2009 Edition 2 2 1) the internal dimensions of th
15、e dilatometer tube, 2) the clearance between tube and piston, 3) the mass of the piston, and 4) the dimensions of the mould. c) Deviation from the specified mean rate and constancy of heating. d) Deviation from the recommendations for the preparation of the sample in respect of maximum particle size
16、, or for the preparation of the pencil. 5 Apparatus 5.1 Apparatus for preparing the coal pencil 5.1.1 Mould with accessories A mould made from steel (case-hardened after machining) and having a polished, uniformly tapered bore, with a tamping pin and a pencil gauge, essentially as shown in figure 2.
17、 Check the mould periodically during use, e.g. with a suitable, appropriately calibrated, tapered gauge or set of gauges inserted through the larger orifice of the mould, to ensure continued compliance with the dimensional requirements for the bore. Replace the mould if necessary. 5.1.2 Press, a scr
18、ew press with a pressure gauge having a range of 0 MPa to 1 000 MPa, as shown in figure 3. NOTE The commercial pressure gauge normally supplied with the apparatus is graduated in tonne, and has a range of 0 tonne to 3 tonne. 5.1.3 Mallet, with a plastics head, and that has a mass of approximately 20
19、0 g. 5.2 Dilatometer, as shown in figure 4, and consisting essentially of the following components: a) Electric furnace, consisting basically of a cylindrical block of aluminium bronze of approximate length and diameter 460 mm and 65 mm respectively, that is heated by a metallic winding that is suit
20、ably insulated, and that has at least three vertical holes of depth at least 380 mm and diameter 15 mm 0,1 mm. One of the holes is used for the measurement of the temperature of the furnace (see 5.2(b). The furnace is capable of providing a rate of heating of 3 C/min up to a temperature of 550 C. It
21、s calibration is such that, in respect of each hole used for holding a dilatometer tube (for actual dilatometric examination of a sample) and at a temperature of approximately 450 C, the temperature inside a dilatometer tube (placed in its normal position in a hole) at a position 30 mm above the int
22、ernal base of the tube (equivalent to the temperature registered by the calibrated temperature-measuring device in its normal position (see 5.2(b) and clause 6) and the temperature at any other position along its length differ by less than 1) 2 C in the lowest 120 mm of the tube, 2) 5 C in the regio
23、n 120 mm to 180 mm from the bottom of the tube, and 3) 10 C in the region 180 mm to 250 mm from the bottom of the tube. The furnace is equipped with a temperature controller of the automatic programmed type and such that, over a temperature range of 250 C to 550 C, a mean rate of temperature rise of
24、 3 C 0,05 C/min is maintained with a maximum variation of 1 C/30 C rise in any 10 min period. This standard may only be used and printed by approved subscription and freemailing clients of the SABS.SANS 6072:2009 Edition 2 3 NOTE If a dilatometer tube is no longer capable of being freely suspended f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS60722009COKINGPROPERTIESOFCOALRUHRDILATOMETERTEST 成焦性 鲁尔 膨胀 试验 PDF

链接地址:http://www.mydoc123.com/p-1031354.html