SANS 1015-2008 Fire resisting door units for record rooms《病历室用耐火门装置》.pdf
《SANS 1015-2008 Fire resisting door units for record rooms《病历室用耐火门装置》.pdf》由会员分享,可在线阅读,更多相关《SANS 1015-2008 Fire resisting door units for record rooms《病历室用耐火门装置》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-21524-8 SANS 1015:2008Edition 1.2Any reference to SABS 1015 is deemedto be a reference to this standard(Government Notice No. 1373 of 8 No
4、vember 2002)SOUTH AFRICAN NATIONAL STANDARD Fire resisting door units for record rooms Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standards South Africa SANS 1015:2008
5、 Edition 1.2 Table of changes Change No. Date Scope Amdt 1 1976 Amended to amplify the text of the scope, and the definition for “Fire resisting door unit” amended to make it clear that the specification covers metal fire resisting door units only. Amdt 2 2008 Amended to change the designation of SA
6、BS standards to SANS standards, to update the definition of “acceptable”, to delete reference to the standardization mark scheme, and to update referenced standards. Foreword This South African standard was approved by National Committee StanSA SC 5120.14A, Security Safes and strongroom doors, in ac
7、cordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This document was published in June 2008. This document supersedes SABS 1015:1974 (first edition). A vertical line in the margin shows where the text has been technically modified by amendment No
8、. 2. SANS 1015:2008 Edition 1.2 1 Contents Page Foreword 1 Scope 3 2 Definitions . 3 3 Requirements 4 4 Marking . 6 5 Inspection and methods of test 6 5.1 Inspection and records 6 5.2 Group test samples . 7 5.3 Tests for scratch resistance and adhesion of paint finishes 7 5.4 Test for nickel and chr
9、ome plated coatings 7 5.5 Test for level locks 7 5.6 Test for boltwork . 7 5.7 Test for door and hinges . 7 5.8 Fire test . 7 Appendix A Applicable standards . 9 Appendix B Notes to purchasers . 9 SANS 1015:2008 Edition 1.2 2 This page is intentionally left blank SANS 1015:2008 Edition 1.2 3 Fire re
10、sisting door units for record rooms1)1 Scope This specification covers the requirements for metal fire resisting door units that are capable of passing a test in which they are gradually heated (over a period of 60 min) to a temperature of 945 C and are then maintained at that temperature for 30 min
11、. Amdt 1 NOTE a) Because it is impractical to test samples taken from each consignment of fire resisting door units for compliance with some of the requirements of this specification, no specific sampling procedure has been included. The tests specified in section 5 shall be carried out, under the s
12、upervision of an independent authority, on at least one fire resisting door unit from each group (as defined in section 2). Some of the requirements and their allied tests are of such a nature that compliance can be proved only by means of a suitable agreement between supplier and purchaser. This ag
13、reement would have to include: Amdt 2 1) the submission to the purchaser of proof of compliance with the specification of the prototype, i.e. the group test sample (see 5.2); and 2) the granting to the purchaser of access to records of raw materials used and of access to the factory to ensure that h
14、is consignment of fire resisting door units has been made in the same manner as the prototype and from materials at least equal in quality to those used in the manufacture of the prototype. b) The titles of standards referred to by number in the specification are given in appendix A. c) Requirements
15、 that must be specified by the purchaser and a requirement that must be agreed upon between purchaser and supplier are listed in appendix B. 2 Definitions 2.1 For the purposes of this specification the following definitions shall apply: acceptable acceptable to the authority administering this stand
16、ard, or to the parties concluding the purchase contract, as relevant Amdt 2 door the movable part (of a door unit) complete with lock and boltwork door-frame the fixed part (of a door unit) that is intended to be built into a wall, and on which the door hangs and against which it closes 1) Strongroo
17、m and vault doors are covered by SANS 949. SANS 1015:2008 Edition 1.2 4 door furniture handle, escutcheon, and nameplate fire resisting door unit a complete door and door-frame assembly made of metal(s) and fire resisting insulating materials, and comprising a door, a door-frame, and door furniture
18、Amdt 1 group fire resisting doors of the same design and size, made by one manufacturer from identical materials inner face the face of a door that faces the inside of a record room inspector the purchaser or his authorized representative outer face the face of a door that faces away from a record r
19、oom and from which the handle projects 3 Requirements 3.1 Materials 3.1.1 Steels and metal alloys Steels and metal alloys used in the manufacture of fire resisting doors shall be capable of withstanding the relevant tests described in section 5. 3.1.2 Materials for door furniture Furniture shall be
20、of an acceptable metal that is intrinsically corrosion resistant or that has a nickel and chromium plated coating that complies with the requirements of SANS 135 for No. 2 service conditions. Amdt 2 3.1.3 Fire resisting material Fire resisting insulating material shall be an acceptable, non-combusti
21、ble, heat resisting, thermal insulating material that is not hygroscopic and does not become compacted when subjected to vibration. 3.2 Hinges Hinges shall be such that the door can be opened sufficiently to present the full and unrestricted opening of the doorway, and shall incorporate acceptable f
22、acilities for lubricating the hinges. 3.3 Boltwork a) Boltwork shall be so designed, constructed, and installed that it operates easily and efficiently, and that components can be repaired or replaced by properly qualified technicians without undue difficulty. b) When a door is tested as described i
23、n 5.6, the boltwork and door handle shall, at the end of the test, show no sign of undue damage and shall still operate efficiently. SANS 1015:2008 Edition 1.2 5 3.4 Doors and frames a) The mating of the relative surfaces of a door and frame of a door unit shall be acceptable and the design, constru
24、ction, strength, and rigidity of the unit shall be such as to ensure that it can be so installed that there is alignment between door and door-frame, and smooth and efficient operation of hinges and bolt-work during normal working. The keyhole shall be fitted with an escutcheon. b) Unless a door-fra
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS10152008FIRERESISTINGDOORUNITSFORRECORDROOMS 病历室 耐火 装置 PDF

链接地址:http://www.mydoc123.com/p-1028636.html