SAE J 2888-2013 R-1234yf Service Hose Fittings and Couplers for Mobile Refrigerant Systems Service Equipment《汽车制冷剂系统维修设备用R-1234yf维修软管 配件和耦合器》.pdf
《SAE J 2888-2013 R-1234yf Service Hose Fittings and Couplers for Mobile Refrigerant Systems Service Equipment《汽车制冷剂系统维修设备用R-1234yf维修软管 配件和耦合器》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2888-2013 R-1234yf Service Hose Fittings and Couplers for Mobile Refrigerant Systems Service Equipment《汽车制冷剂系统维修设备用R-1234yf维修软管 配件和耦合器》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2888_201301 AEROSPACE SURFACE VEHICLE RECOMMENDED PRACTICE J2888 JAN2013 Issued
5、2011-02 Revised 2013-01 Superseding J2888 JAN2012 R-1234yf Service Hose, Fittings and Couplers for Mobile Refrigerant Systems Service Equipment RATIONALE Updated Figures for service hose fittings, clarify fitting requirements and revise the appendix for SAE J2911. 1. SCOPE This SAE Standard covers f
6、ittings, couplers, and hoses intended for connecting service hoses from mobile air- conditioning Systems to service equipment such as charging, recovery and recycling equipment. (Figure 1) This specification covers service hose fittings and couplers for MAC service equipment service hoses, per SAE J
7、2843 and SAE J2851, from mobile air-conditioning systems to service equipment such as manifold gauges, vacuum pumps, and air-conditioning charging, recovery and recycling equipment. 1.1 Purpose The purpose of this SAE Standard is to establish specific but unique fittings, couplers, and hoses for ser
8、vice equipment used in maintaining R-1234yf systems. This is necessary to avoid cross mixing of refrigerant and lubricants from other refrigerant systems. This standard applies only to systems specifically designed to use R-1234yf. Hermetically sealed appliances and refrigerated cargo systems are no
9、t covered by this document. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International, 400 C
10、ommonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. 2.1.1.1 System Design Guidelines SAE J639 Safety Standards for Motor Vehicle Refrigerant Vapor Compressions Systems 2.1.1.2 Technician Service Procedures SAE J2845 R-12
11、34yf HFO-1234yf and R-744 Technician Training for Service and Containment of Refrigerants Used in Mobile A/C Systems 2.1.1.3 Service Equipment SAE J2888 Revised JAN2013 Page 2 of 12 SAE J2843 R-1234yf HFO-1234yf Recovery/Recycling/Recharging Equipment for Flammable Refrigerants for Mobile Air-Condit
12、ioning Systems SAE J2844 R-1234yf (HFO-1234yf) New Refrigerant Purity and Container Requirements for use in Mobile Air-Conditioning Systems SAE J2851 Recovery Equipment for Contaminated Refrigerant from Mobile Automotive Air Conditioning Systems 2.1.2 Reference Documents SAE J1739 Potential Failure
13、Mode and Effects Analysis in Design (Design FMEA), Potential Failure Mode and Effects Analysis in Manufacturing and Assembly Processes (Process FMEA) SAE J2911 Procedure for Certification that Requirements for Mobile Air Conditioning System Components, Service Equipment, and Service Technician Train
14、ing Meet SAE J Standards. This Standard provides manufacturers, testing facilities and technician knowledge requirement providers with a procedure of certifying compliance with the appropriate SAE standard. 2.1.3 ARI Publication Available from Air Conditioning and Refrigeration Institute, 1501 Wilso
15、n Boulevard, Sixth Floor, Arlington, VA 22209. ARI 720 Refrigerant Access Valves and Hose Connectors FIGURE 1 - R-1234yf SERVICE EQUIPMENT SAE J2888 Revised JAN2013 Page 3 of 12 3. DEFINITIONS 3.1 HIGH SIDE SERVICE HOSE A hose connected between the MAC high-side service fitting and the recovery equi
16、pment. It includes a high-side coupling, as defined in SAE J639, and at the shutoff device of the connection to the serviced system or equipment, an M12 x 1.5-6g male thread on both ends. 3.2 LOW SIDE SERVICE HOSE A hose connected between the MAC low-side service fitting and the recovery equipment.
17、It includes a low-side coupling, as defined in SAE J639, and at shutoff device of the connection to the serviced system or equipment, an M12 x 1.5-6g male thread on both ends. 3.3 SUPPLY HOSE (utility) A hose connected between the R-1234yf supply cylinder and the service equipment (recovery/recyclin
18、g recovery/recycle/charging unit). On one end, the supply hose shall have a compatible coupling per SAE J2844 to connect to the refrigerant supply cylinder. See Figure 2 and Table 1 The other end of the supply hose, if connected externally to the service equipment, shall contain an M12 x 1.5-6g male
19、 threaded connection. 3.3.1 The supply hose at the refrigerant cylinder connection shall have a left hand female thread, inch, 16 TPI ACME fitting. 3.3.2 The R-1234yf refrigerant cylinder has the following fitting. FIGURE 2 - R-1234YF REFRIGERANT CYLINDER SAE J2888 Revised JAN2013 Page 4 of 12 TABLE
20、 1 - SUMMARY OF R-1234YF REFRIGERANT CYLINDER 3.4 INTERNAL HOSE A hose connected between components within or as part of service equipment. If the connection is made external to the unit, it shall be a wrench tight connection different than those described for the high-side, low-side service hose an
21、d supply hose as previously defined. 3.5 CHARGE SERVICE COUPLING The female connector intended to be used with the MAC service fittings (ports) as identified in SAE J639. 4. TECHNICAL REQUIREMENTS 4.1 Charge Service Coupling 4.1.1 Charge Service couplings for high and low side shall meet the require
22、ments and be compatible as defined in SAE J639. The charge service coupling shall be constructed to prevent discharge when decoupled and shall have a manual valve to actuate flow, this valve shall have a lock out feature that prevents actuation until the coupler is securely locked into place on the
23、charge port. 4.1.2 The charge service coupling must be designed for sealing on the outer diameter of the charge port to prevent leakage due to variation in the charge port end configuration. 4.1.3 The charge service coupling must remain sealed and be able to hold pressures from 3.4 MPa to 759.5 mm o
24、f Hg (500 psi to 29.9 Hg) when decoupled from service fitting regardless of the valve position. 4.1.4 The valve core pin depressor feature of the charge service coupling shall provide a minimum of 0.25 mm to the top of the valve core pin when fully retracted allowing it to be coupled and de-coupled
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ28882013R1234YFSERVICEHOSEFITTINGSANDCOUPLERSFORMOBILEREFRIGERANTSYSTEMSSERVICEEQUIPMENT 汽车 制冷剂 系统

链接地址:http://www.mydoc123.com/p-1027668.html