SAE J 823-1994 Flasher Test Standard《闪光测试》.pdf
《SAE J 823-1994 Flasher Test Standard《闪光测试》.pdf》由会员分享,可在线阅读,更多相关《SAE J 823-1994 Flasher Test Standard《闪光测试》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.QUESTIONS REGARDING THIS DOCUMENT: (412) 772-8512 FAX: (412) 776-0243TO PLACE A DOCUMENT
3、 ORDER; (412) 776-4970 FAX: (412) 776-0790SAE WEB ADDRESS http:/www.sae.orgCopyright 1994 Society of Automotive Engineers, Inc.All rights reserved. Printed in U.S.A.SURFACEVEHICLE400 Commonwealth Drive, Warrendale, PA 15096-0001STANDARDSubmitted for recognition as an American National StandardJ823RE
4、V.JAN94Issued 1962-04Revised 1994-01Superseding J823 JUN91FLASHER TESTForewordThis Document has not changed other than to put it into the new SAE Technical Standards BoardFormat.1. ScopeThis SAE Standard specifies the test procedure, test circuitry, and instruments required formeasuring the performa
5、nce of flashers used in motor vehicles.2. ReferencesThere are no referenced publications specified herein.3. Laboratory FacilitiesThe laboratory shall be equipped with all of the facilities required to make the tests inthis document, in accordance with established laboratory practice, including the
6、following:3.1 Ambient ConditionsMeans shall be provided to maintain ambient temperatures over the range from 32 to63 C within the tolerances specified for each test condition, in an air atmosphere.3.2 Power SupplyPerformance TestsThe power supply for testing performance requirements shall notgenerat
7、e any adverse transients not present in motor vehicles and shall comply with the followingspecifications:3.2.1 OUTPUT VOLTAGECapable of supplying to the input terminals of the standard circuit 11 to 16 V DC for 12 Vflashers or 5.5 to 8 V DC for 6 V flashers or 22 to 32 V DC for 24 V flashers.3.2.2 O
8、UTPUT CURRENTCapable of supplying required design current(s) continuously and inrush currents asrequired by the design bulb load complement.3.2.3 REGULATION3.2.3.1 DynamicThe output voltage shall not deviate more than 1.0 V from 0 to maximum load (including inrushcurrent) and shall recover within th
9、e area generated by the equation 1.0 V(1-et/T), T = 100 s. The curveshall end at the maximum voltage deviation allowed for static regulation (see Figure 1).3.2.3.2 StaticThe output voltage shall not deviate more than 2% with changes in static load from 0 to maximum(not including inrush current) nor
10、for static line voltage variations.3.2.4 RIPPLE VOLTAGEMaximum 75 mV, peak to peak, from 0 to maximum design bulb load.SAE J823 Revised JAN94-2-FIGURE 1POWER SUPPLYMAXIMUM DYNAMIC REGULATION CURVE3.3 Power SupplyDurability TestsThe power supply for the durability test requirements shall not generate
11、any adverse transients not present in motor vehicles and shall comply with the following specifications:3.3.1 OUTPUT VOLTAGECapable of supplying, as required, 14 and 13 V (7 and 6.5 V DC or 28 and 26 V),according to the flasher rating, to the input terminals of the standard test circuits shown in Fi
12、gures 2 and 3.FIGURE 2STANDARD TEST CIRCUITTURN SIGNAL AND HAZARD WARNING FLASHERSSAE J823 Revised JAN94-3-FIGURE 3STANDARD TEST CIRCUITWARNING LAMP ALTERNATING FLASHERS3.3.2 OUTPUT CURRENTCapable of supplying a continuous output current of the design load for one flasher timesthe number of flashers
13、 and inrush currents as required by the bulb load complement.3.3.3 REGULATION3.3.3.1 DynamicThe output voltage shall not deviate more than 1.0 V from 0 to maximum load (including inrushcurrent) and shall recover within the area generated by the equation 1.0 V(1-et/T), T = 5 ms. The curveshall end at
14、 the maximum voltage deviation allowed for static regulation (see Figure 1).3.3.3.2 StaticThe output voltage shall not deviate more than 2% with changes in static load for 0 to maximum(not including inrush current), and means shall be provided to compensate for static line voltage variations.3.3.4 R
15、IPPLE VOLTAGEMaximum 300 mV, peak to peak, from 0 to maximum design bulb load for one flashertimes the number of flashers.4. Test Procedures4.1 The flashers shall be mounted as specified by the manufacturer if special precautions are required.4.2 The flashers shall be connected in a standard test ci
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ8231994FLASHERTESTSTANDARD 闪光 测试 PDF