1、 _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising ther
2、efrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2015 SAE International All rights reserved. No part of this
3、publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-49
4、70 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2030_201506 SURFACE VEHICLE STANDARD J2030 JUN2015 Issued 1994-11 Revised 2015-
5、06 Superseding J2030 JUN2009 Heavy-Duty Electrical Connector Performance Standard RATIONALE Updated MIL specification reference with EIA specification. FOREWORD NOTICE: Some test procedures are potentially dangerous. SAE Technical Reports do not purport to address all of the safety problems, if any,
6、 associated with their use. It is the responsibility of the user of an SAE Technical Report to establish and employ appropriate safety practices. Tests should only be conducted by individuals who have been properly trained in the test procedure and who are aware of any hazards which might be present
7、. Appropriate safety and health precautions must be employed when conducting any test. 1. SCOPE This SAE Standard encompasses connectors between two cables or between a cable and an electrical component and focuses on the connectors external to the electrical component. This document provides enviro
8、nmental test requirements and acceptance criteria for the application of connectors for direct current electrical systems of 50 V or less in the majority of heavy-duty applications typically used in off-highway machinery. Severe applications can require higher test levels, or field-testing on the in
9、tended application. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. 2.1.1 SAE Publications Available from SAE International, 400 Commonwea
10、lth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J163 Low Tension Wiring and Cable Terminals and Splice Clips SAE J726 Air Cleaner Test Code SAE INTERNATIONAL J2030 Revised JUN2015 Page 2 of 12 SAE J1455 Recommended Envir
11、onmental Practices for Electronic Equipment Design in Heavy-Duty Vehicle Applications SAE J1614 Wiring Distribution Systems for Construction, Agricultural, and Off-Road Work Machines 2.1.2 ASABE Publication Available from the American Society of Agricultural and Biological Engineers, 2950 Niles Road
12、, St. Joseph, MI 49085-9659, Tel: 269-429-0030, www.asabe.org. ASAEEP455 Environmental Considerations in Development of Mobile Agricultural Electrical/Electronic Components 2.1.3 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-29
13、59, Tel: 610-832-9585, www.astm.org. ASTM D 471 Standard Test Method for Rubber Property - Effect of Liquids ASTM G 153 Standard Practice for Operating Enclosed Carbon Arc Light Apparatus for Exposure of Nonmetallic Materials ASTM G 154 Standard Practice for Operating Fluorescent Light Apparatus for
14、 UV Exposure of Nonmetallic Materials 2.1.4 EIA Standard Available from the Global Documents, 15 Iverness Way East, Englewood, CO 80112-5704, USA, Tel: 303-397-7956, 800-854-7179, http:/ EIA-364-23 Low-Signal Level Contact Resistance 2.2 Related Publications The following publications are provided f
15、or information purposes only and are not a required part of this SAE Technical Report. 2.2.1 API Publication Available from API, 1220 L Street, NW, Washington, DC 20005-4070, Tel: 202-682-8000, www.api.org. API 1560 Lubricant Service Designation for Automotive Manual Transmissions and Axles 2.2.2 IS
16、O Publication Available from American National Standards Institute, 25 West 43rd Street, 4th Floor, New York, NY 10036, Tel: 212-642-4900, www.ansi.org. ISO 8092 Road Vehicles - Connections for On-Board Electrical Harnesses SAE INTERNATIONAL J2030 Revised JUN2015 Page 3 of 12 3. DEFINITIONS 3.1 CONN
17、ECTOR A coupling device, which provides an electrical junction, a mechanical junction, or both, between two cables or between one or more cables and an electrical component. Connectors can also provide for mechanical stability and geometric arrangement. 3.2 TERMINAL An electrically conductive device
18、 attached to a cable to facilitate connection to an electrical component, cable, or termination. 3.3 SEALED A system that creates a nonleaking union between mechanical elements when submerged in a water solution as defined in the tests within this document. 3.4 SIGNAL LEVEL CIRCUIT A circuit in whic
19、h open circuit voltage is typically less than 5 V and current is typically less than 0.05 A. Circuits of this energy level typically are not able to break through oxides, sulfides, or other contaminants, which can build up on the contact surfaces and prevent continuity. 3.5 POWER CIRCUIT A system us
20、ing two or more cables where current flows from the source to one or more electronic/electrical devices and back again to the source. The electrical energy is supplied at high levels of current and typical system voltage (system battery voltage). 3.6 CABLE Insulated stranded electrical conductor use
21、d to establish a single current path. 3.7 WIRING Collectively, the cables, harnesses, connectors, terminations, and supporting components used in the electrical wiring distribution system. 4. SAMPLE PREPARATION Samples shall be made on the connector manufacturers recommended tooling and checked for
22、conformance to the connector manufacturers standards. 4.1 Assembly All connector cavities shall be wired with manufacturers minimum approved cable outside diameter size except for test groups A and D which shall be be wired with manufacturers maximum approved conductor size in lengths sufficient to
23、accommodate testing. Cable diameter shall be checked and be within the connectors manufacturing specification. Crimp characteristics (i.e., height, width, etc.) shall be checked. To prevent capillary action on sealed connectors, all loose wire ends and test points (i.e., millivolt test connection) s
24、hall be sealed with alcohol-base RTV silicone or equivalent. SAE INTERNATIONAL J2030 Revised JUN2015 Page 4 of 12 5. TEST SEQUENCE For qualification testing, test samples shall be subjected to the tests in the order shown in Table 1 with a quantity of 6 for each group. The tests are to be carried ou
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ20302015HEAVYDUTYELECTRICALCONNECTORPERFORMANCESTANDARDPDF

链接地址:http://www.mydoc123.com/p-1026690.html