1、SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirelyvoluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefro
2、m, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions.Copyright 2002 Society of Automotive Engineers, Inc.All rights reserved. No part of this
3、 publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying,recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: 724-776-4970 (o
4、utside USA)Fax: 724-776-0790Email: custsvcsae.orgSAE WEB ADDRESS: http:/www.sae.orgSURFACEVEHICLESTANDARDJ159REV.OCT2002Issued 1970-03Revised 2002-10Superseding J159 APR1994(R) Rated Capacity System1. ScopeThis SAE Standard applies to cranes when used in lifting service that are equipped with RatedC
5、apacity Systems.1.1 PurposeThe purpose of this document is to establish the minimum performance and tolerance criteria ofsystems used to warn or to indicate to the operator and/or other responsible persons when the load beinglifted approaches, meets and exceeds the rated capacity on the applicable r
6、ated capacity chart of the crane.2. References2.1 Applicable PublicationsThe following publications form a part of this specification to the extent specifiedherein.2.1.1 NEMA P UBLICATIONAvailable from the National Electrical Manufacturers Association, www.NEMA.org,1300 North 17th Street, Suite 1847
7、, Rosslyn, VA 22209.NEMA-12 (U.S. Code)2.1.2 IP (INTERNATIONAL ELECTROTECHNICAL COMMISSION) PUBLICATIONAvailable from American NationalStandards Institute (ANSI), Customers Service, 25 West 43rd Street, 4th floor, New York, NY 10036-8002.TP: +1 212 642 4900 TF: +1 212 398 0023 email: infoansi.org UR
8、L: webstore.ansi.org.IP-65 (International Protection Code - IEC 144/855420)3. Definitions3.1 Rated Capacity Indicator (RCI)A system consisting of devices, when applied to a crane, sense craneloading, boom length (telescopic only), boom angle, and which automatically provide an audible/visual signalw
9、hen the Actual Load approaches, reaches and/or exceeds the Rated Capacity value.3.2 Rated Capacity Limiter (RCL)A system consisting of devices which, when applied to a crane, sense craneloading, boom length (telescopic only), boom angle, and which automatically provide an audible/visual signalwhen t
10、he loading conditions approach, reach and/or exceed the rated capacity values. When the Actual Loadexceeds the Rated Capacity, the system supplies a signal to a function kick-out system.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking perm
11、itted without license from IHS-,-SAE J159 Revised OCT2002-2-3.3 Function Kick-Out System (FKO)A device which when activated prevents the loading on the crane to beincreased beyond the point at which the FKO occurred.3.4 Crane ConfigurationThe physical arrangement of the crane as prepared for the par
12、ticular operation inconformance with the manufacturers operating instructions and Rated Capacity Chart.3.5 Actual LoadThe weight of the load being lifted including all additional equipment such as wire rope, blocks,slings, etc. as defined by the manufacturers Rated Capacity Chart.3.6 Rated CapacityT
13、he value shown on the applicable Rated Capacity Chart of the crane for the particularconfiguration, boom length, angle and/or function of these variables. For radii and/or angles outside thoseshown on the Rated Capacity Chart, the rated capacity is considered to be zero.3.7 Boom LengthThe straight l
14、ine through the center line of the boom pivot pin to the centerline of the boompoint hoist sheave pin, measured along the longitudinal axis of the boom.3.8 Boom AngleThe angle between the longitudinal centerline of the boom base section and the horizontalplane.3.9 Radius of LoadThe horizontal distan
15、ce from a vertical projection of the cranes axis of rotation to thesupporting surface, before loading, to the center line of the vertical hoist line(s) or tackle with the load applied.4. Performance Tolerance Criteria4.1 Warning and Limit SignalsVisual and/or audible signals shall have the visual si
16、gnal clearly visible to theoperator under any normal operating conditions, and the audible signal shall be sufficiently loud to be heardover engine and machinery noise, and shall be clearly distinguishable from ambient noise.4.1.1 WARNING S IGNAL - APPROACH TO OVERLOADAn audible and visual signal (p
17、referably a yellow light) is to beactivated at 92% 5% of Rated Capacity. The signal shall continue to function as long as the load, radius orangle parameters exceed the 92% 5% values. Also, the warning signal shall be clearly distinguishable fromthe overload signal.4.1.2 OVERLOAD AND LIMIT S IGNALAn
18、 Audible and Visual signal (preferably a red light) is to be activated at nomore than 105% of Rated Capacity and also when the radius or angle shall fall outside of the cranes RatedCapacity Chart. Also, when a Rated Capacity Limiter is employed to actuate an optional crane controlFunction Kick-Out S
19、ystem (FKO), the FKO is to be activated at no more than 105% of Rated Capacity.These signals shall continue to function as long as the load, radius, and angle parameters are exceeded.4.2 Additional FunctionsWhen actual load, rated capacity, radius, boom angle or boom length are displayedas additiona
20、l functions of a Rated Capacity System the displayed function is to conform to the followingprovided that the system accuracy always conforms to 4.1.1 and 4.1.2.4.2.1 ACTUAL LOADWhen Actual Load is displayed as an additional function of a Rated Capacity System itsaccuracy shall be such that the indi
21、cated load is 100% +10% 0% of the Actual Load. 4.2.2 RADIUSWhen Radius is displayed as an additional function of a Rated Capacity System its accuracy is tobe such that the indicated radius is 100% +10% 0% of the Actual Load Radius.4.2.3 BOOM LENGTHWhen boom length is displayed as an additional funct
22、ion of a Rated Capacity System itsaccuracy is to be such that the indicated length is 100% 2% of the actual length.Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-SAE J159 Revised OCT2002-3-4.2.4 BOOM
23、ANGLEWhen Boom Angle is displayed as an additional function of a Rated Capacity System itsaccuracy shall be as follows: For boom angles 65 degrees or higher the indicated angle is to be neithergreater than the actual boom angle nor more than 2 degrees less than the actual boom angle. For boomangles
24、less than 65 degrees the indicated angle is to be neither greater than the actual boom angle nor morethan 3 degrees less than the actual boom angle.4.2.5 RATED CAPACITYWhere rated capacity is displayed as an additional function of a Rated Capacity Systemthe capacity displayed shall be the capacity d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ1592002RATEDCAPACITYSYSTEM 额定 功率 系统 PDF