1、 AEROSPACE STANDARD CABLE, POWER, ELECTRICAL, 600 VOLTS, PORTABLE, MULTICONDUCTOR AS5756/3 Copyright 2016 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopyi
2、ng, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED2004-06REVISED2010-10REAFFIRMED 2
3、016-05THIRD ANGLE PROJECTION CUSTODIAN: AE-8/AE-8D REV.A FEDERAL SUPPLY CLASS 6145 AS5756/3 SHEET 1 OF 4 REV. A PROCUREMENT SPECIFICATION: AS5756 SAE Technical Standards BoardRules providethat:“This reportis publishedby SAE to advance thestateoftechnical andengineering sciences. The useofthis report
4、is entirely voluntary, and its applicability and suitability forany particularuse, includingany patent infringement arising therefrom, is thesole responsibility of theuser.” SAE reviews eachtechnical reportatleastevery five years at whichtime it may berevised, reaffirmed, stabilized, or cancelled. S
5、AEinvites your written comments and suggestions. SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS5756/3A RATIONALE AS5756/3A HAS BEEN REAFFIRMED TO COMPLY WITH THE SAE FIVE-YEAR REVIEW POLICY. THE REQUIREMENTS FOR PROCURING TH
6、E CONTACTS DESCRIBED HEREIN SHALL CONSIST OF THIS SPECIFICATION AND THE LATEST ISSUE OF: SAE AS5756 FIGURE 1 EXAMPLE OF 3 CONDUCTOR CABLE REQUIREMENTS: QUALIFICATION REQUIRED. CONSTRUCTION (SEE TABLE 1) FIRST - COPPER CONDUCTOR, SEE TABLE I OF AS5756 FOR REQUIREMENTS, SIZES 10 AWG AND SMALLER SHALL
7、BE TIN-COATED, SIZES 8 AWG AND LARGER SHALL BE UNCOATED. SECOND - SEPARATOR, REQUIRED WHERE UNCOATED CONDUCTORS ARE USED, OPTIONAL WHERE TIN-COATED CONDUCTORS ARE USED. THIRD - INSULATION OF SYNTHETIC OR NATURAL RUBBER (SEE TABLE I FOR THICKNESS), COLOR CODED PER PARAGRAPH 3.4.6 OF AS5756. FOURTH -
8、THE REQUIRED NUMBER OF CONDUCTORS CABLED TOGETHER WITH A LEFT-HAND LAY NOT GREATER THAN 16 TIMES THE DIAMETER UNDER THE JACKET. WHEN NEEDED, FILLERS SHALL BE EMPLOYED TO OBTAIN A FIRM, WELL-ROUNDED ASSEMBLY. FIFTH - BINDER TAPE APPLIED HELICALLY WITH OVERLAP. SIXTH - NATURAL OR SYNTHETIC RUBBER JACK
9、ET (SEE TABLE I FOR THICKNESS). CABLE SURFACE MARKING REQUIRED. OZONE RESISTANCE - REQUIRED. NOTICE AEROSPACE STANDARD AS5756/3 SHEET 2 OF 4 REV. A CABLE, POWER, ELECTRICAL, 600 VOLTS, PORTABLE, MULTICONDUCTOR TABLE 1 DETAILS OF CONSTRUCTION PART NO. M5756/3 CONDUCTOR SIZE NUMBER OF CONDUCTORS NOMIN
10、AL INSULATIONTHICKNESS(INCH) 1/ NOMINAL JACKET THICKNESS(INCH) 2/ OVERALL DIAMETER OF JACKETED CABLECONDUCTOR RESISTANCE PER 1000 FEET (MAX) 20C (OHMS) NOMINAL WEIGHT PER1000 FEET (POUNDS) 3/ MIN (INCHES) MAX (INCHES) -001 18 2 .031 .0625 .316 .375 7.49 60.9 -002 16 2 .031 .0625 .338 .399 4.70 72.5
11、-003 14 2 .047 .078 .429 .530 2.96 127.9 -004 12 2 .047 .078 .499 .576 1.86 159.3 -005 10 2 .047 .094 .549 .648 1.20 217.7 -006 8 2 .063 .109 .705 .824 .699 335.0 -007 6 2 .063 .125 .831 .962 .444 487.2 -008 4 2 .063 .141 .965 1.100 .279 676.9 -009 2 2 .063 .156 1.150 1.270 .177 945.1 -010 1 2 .078
12、.156 1.270 1.410 .141 1173.1 -011 1/0 2 .078 .172 1.360 1.540 .111 1422.5 -012 2/0 2 .078 .187 1.560 1.740 .0893 1780.0 -013 3/0 2 .078 .187 1.710 1.890 .0708 2131.3 -014 4/0 2 .078 .203 1.840 2.050 .0562 2586.6 -015 250 2 .094 .203 2.010 2.220 .0476 3045.2 -016 18 3 .031 .0625 .331 .392 7.49 71.9 -
13、017 16 3 .031 .0625 .356 .418 4.70 87.2 -018 14 3 .047 .078 .482 .557 2.96 154.0 -019 12 3 .047 .094 .527 .606 1.86 213.9 -020 10 3 .047 .094 .611 .692 1.20 268.9 -021 8 3 .063 .109 .772 .869 .699 429.9 -022 6 3 .063 .141 .910 1.100 .444 639.5 -023 4 3 .063 .156 1.050 1.190 .279 888.4 -024 2 3 .063
14、.172 1.210 1.310 .177 1252.9 -025 1 3 .078 .172 1.350 1.520 .141 1556.6 -026 1/0 3 .078 .172 1.480 1.630 .111 1837.1 -027 2/0 3 .078 .187 1.680 1.840 .0893 2295.1 -028 3/0 3 .078 .203 1.820 2.030 .0708 2832.2 -029 4/0 3 .078 .203 1.990 2.180 .0562 3369.2 -030 250 3 .094 .203 2.140 2.360 .0476 3995.8
15、 -031 18 4 .031 .0625 .358 .421 7.49 85.2 -032 16 4 .031 .0625 .385 .450 4.70 104.8 -033 14 4 .047 .078 .523 .601 2.96 185.6 -034 12 4 .047 .094 .603 .689 1.86 258.4 -035 10 4 .047 .109 .664 .749 1.20 349.2 1/ THE MINIMUM INSULATION THICKNESS SHALL BE AT LEAST 90% OF THE NOMINAL. 2/ THE MINIMUM JACK
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS57563A2010CABLEPOWERELECTRICAL600VOLTSPORTABLEMULTICONDUCTOR600V 便携式 导体 电缆 PDF

链接地址:http://www.mydoc123.com/p-1024941.html