《SAE AS 5692A-2009 ARC Fault Circuit Breaker (AFCB) Aircraft Trip-Free Single Phase 115 VAC 400 Hz - Constant Frequency《自动跳闸单相115VAC 400Hz固定频率航空器用电弧故障断路器(AFCB)》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 5692A-2009 ARC Fault Circuit Breaker (AFCB) Aircraft Trip-Free Single Phase 115 VAC 400 Hz - Constant Frequency《自动跳闸单相115VAC 400Hz固定频率航空器用电弧故障断路器(AFCB)》.pdf(64页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2009 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside US
4、A) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/AS5692AAEROSPACESTANDARDAS5692 REV. A Issued 2004-10 Revised 2009-12 Superseding AS5692 (R) ARC
5、 Fault Circuit Breaker ( AFCB), Aircraft, Trip-Free Single Phase and Three Phase 115 VAC, 400 Hz - Constant Frequency RATIONALEUpdate specification to include three phase arc fault circuit breakers update requirements to comprehend three phase requirements.FOREWORDThermal circuit breakers are design
6、ed to react to the heating effect of current carried by wire; and to protect the wire insulation from thermal damage. These protective devices are not designed to detect or react to the short duration of arcing faults that typically occur outside (before approaching) the defined trip region, or Time
7、 versus Current Curve, of the thermal circuit breakers.In addition, arc impedance can reduce low voltage fault current magnitudes appreciably. AFCBs combine active arc fault detection with thermal overload protection into one package. Supplemented with the arc fault detection, the AFCB provides an e
8、quivalent level of thermal protection of existing thermal circuit breakers (typically qualified under AS58091), with the added ability to detect and react to arc fault conditions, thereby mitigating damage that will occur to the wiring system by protracted arcing events. It is important to note that
9、 the primary purpose of the AFCB as stated above is to mitigate damage to the aircraft wiring from the circuit breaker to the first serial load element (examples: LRU, transformer, ballast, rectifier, or connected equipment, etc.). In doing so, the potential of igniting surrounding materials is redu
10、ced, but not eliminated. Use of AFCBs for hazard mitigation/prevention beyond its intended function of mitigating damage to the aircraft wiring should be carefully analyzed and evaluated. NOTE: AS58091 was used as the base document for this AFCB specification as such the tables comprehend future amp
11、 rating expansion from to 200A. Copyright SAE International Provided by IHS under license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE AS5692A Page 2 of 641. SCOPE 1.1 Scope The primary function of this specification is to cover the general requireme
12、nts for manual reset trip-free arc fault/thermal circuit breakers for use in aircraft electrical systems conforming to MIL-STD-704. As a secondary function, this specification may possibly cover the general requirements for AFCBs for use in primary vehicles, other than aircraft, when mounted directl
13、y to the structure. 1.2 Classification AFCBs shall be the Thermal Type, and classified into different styles. Variations from the basic style of each AFCB shall be indicated by the part number from the appropriate specification sheet (see 3.1). 1.2.1 Styles AFCB styles shall consist of all part numb
14、ers covered by one Aerospace Standard or specification sheet. For example: a. All part numbers of AS5692/1 shall be the same style. b. All part numbers of AS5692/2 shall be the same style. The same style classification applies to all Aerospace Standards and specification sheets covered by this speci
15、fication. 1.2.2 Part Number The part numbers for AFCBs in accordance with this specification shall conform to part number scheme below. Alphanumeric characters shall be used to designate variations from the basic style of each circuit breaker. Example of part number scheme (amend p/n to comprehend 2
16、A5)AS5692/1-DA5VL| _ Pushbutton (1.2.4) | _ High Vibration Capability (1.2.6) | _ Auxiliary Terminals (1.2.5) | _ Amperage Rating (1.2.3) | _ Random Vibration Capability (1.2.6) | _ Basic part style AS5692/1 (1.2.1) When a designator for a variation is not applicable it shall be omitted from the par
17、t number. Not all letters are applicable for every specification sheet. Refer to the latest specification sheet and QPL for available and qualified configurations. 1.2.3 Amperage Ratings The amperage rating designator shall be a number specified in each specification sheet to indicate the nominal am
18、perage rating for overload protection. 1.2.4 Pushbuttons The AFCB pushbutton shall be designated as follows. Standard length pushbutton, as specified in the specification sheet shall have no designator letter. L - Extra length pushbutton (see 6.3.9) Copyright SAE International Provided by IHS under
19、license with SAENot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE AS5692A Page 3 of 641.2.5 Auxiliary Switch Terminals The use of auxiliary switch terminals when allowed by the specification sheet shall be designated as follows. AFCBs with standard terminals only
20、, as specified in the specification sheet, shall have no designator letter. A - Auxiliary switch terminals 1.2.6 Vibration Level The vibration level of the AFCB shall be specified in the specification sheet and shall be indicated in the part number by one or more of the following designators. Standa
21、rd sine vibration capabilities shall have no designator. (see 4.7.11.2). V - High Level sine capabilities (see 4.7.11.3). C thru K - Random vibration capabilities (see 4.7.11.1). 1.2.7 Mounting Configurations Unless otherwise specified, the AFCB mounting configuration shall be designated as follows.
22、 Standard bushing mounted circuit breakers shall have no designator. P - Cover-plate mount. 2. APPLICABLE DOCUMENTS 2.1 Government Specifications, Standards and Handbooks 2.1.1 The following specifications, standards and handbooks form a part of this specification to the extent specified herein.Avai
23、lable from the Document Automation and Production Service (DAPS), Building 4/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094, Tel: 215-697-6257, http:/assist.daps.dla.mil/quicksearch/.A-A-52080 Tape, Lacing and Tying, Nylon A-A-52081 Tape, Lacing and Tying Polyester A-A-52082 Tape, Lacing and Tyi
24、ng, TFE-Fluorocarbon A-A-52083 Tape, Lacing and Tying, Glass A-A-52084 Tape, Lacing and Tying, Aramid MIL-I-24768/17 Insulation, Plastic, Laminated, Thermosetting, Glass-Cloth, Silicone-Resin (GSG) MIL-DTL-81381 Wire, Electric, Polyimide Insulated, Copper or Copper Alloy MIL-E-17555 Electronic and E
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS5692A2009ARCFAULTCIRCUITBREAKERAFCBAIRCRAFTTRIPFREESINGLEPHASE115VAC400HZCONSTANTFREQUENCY 自动 跳闸

链接地址:http://www.mydoc123.com/p-1024925.html