SAE AS 5692 3-2012 ARC FAULT CIRCUIT BREAKER C AIRCRAFT TRIP FREE 1 TO 20 AMP TYPE I《1型自由脱扣的航空用故障电弧断路器(1 20 AMP)》.pdf
《SAE AS 5692 3-2012 ARC FAULT CIRCUIT BREAKER C AIRCRAFT TRIP FREE 1 TO 20 AMP TYPE I《1型自由脱扣的航空用故障电弧断路器(1 20 AMP)》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 5692 3-2012 ARC FAULT CIRCUIT BREAKER C AIRCRAFT TRIP FREE 1 TO 20 AMP TYPE I《1型自由脱扣的航空用故障电弧断路器(1 20 AMP)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、AEROSPACE STANDARD ARC FAULT CIRCUIT BREAKER AIRCRAFT, TRIP FREE, 1 TO 20 AMP, TYPE I AS5692/3Copyright 2012 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photoco
2、pying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org ISSUED 2012-02THIRD ANGLE PROJECTION
3、 CUSTODIAN: E-25 FEDERAL SUPPLY CLASS 5925 AS5692/3SHEET 1 OF 6PROCUREMENT SPECIFICATION: NONESAE Technical Standards Board Rules provide that: “This report ispublishedby SAE toadvance thestate of technicalandengineering sciences. Theuse ofthis report is entirely voluntary, andits applicability and
4、suitability forany particular use,including any patent infringement arising therefrom, isthe soleresponsibilityofthe user.”SAE reviews eachtechnicalreport at least every five years at which time itmay berevised, reaffirmed, stabilized, orcancelled. SAE invites yourwrittencomments andsuggestions. SAE
5、 values your input. To provide feedbackon this Technical Report, please visit http:/www.sae.org/technical/standards/AS5692/3RATIONALE THIS DOCUMENT IS CREATED TO ALLOW PROCUREMENT OF AFCBS THAT MEET THE REQUIREMENTS OF THIS DRAWING AND THE BASE DOCUMENT AS5692. THE REQUIREMENT FOR ACQUIRING THE PROD
6、UCT(S) DESCRIBED HEREIN SHALL CONSIST OF THE SPECIFICATION LISTED AND THE ISSUE OF AS5692 FIGURE 1 - CIRCUIT BREAKER CONFIGURATIONS AND DIMENSIONS AEROSPACE STANDARD AS5692/3SHEET 2 OF 6ARC FAULT CIRCUIT BREAKER AIRCRAFT, TRIP FREE, 1 TO 20 AMP, TYPE I FIGURE 1 - CIRCUIT BREAKER CONFIGURATIONS AND D
7、IMENSIONS (CONTD) FIGURE 2 - CIRCUIT BREAKER CONFIGURATIONS AND DIMENSIONS (CONTINUED) AEROSPACE STANDARD AS5692/3SHEET 3 OF 6ARC FAULT CIRCUIT BREAKER AIRCRAFT, TRIP FREE, 1 TO 20 AMP, TYPE I TABLE 1 - ELECTRICAL AND MECHANICAL CHACTERISTICS DASHNO. NOMINAL AMPERAGE RATING(A) VOLTAGE DROP MAX (V) W
8、EIGHT MAX (LBS) OPERATING FORCE MAX. (LBS) ENDURANCE CYCLES MECH NO LOADCYCLES RESISTIVE INDUCTIVE PULLOUT RESET AC AC 2- 2.5 (2-) 0.70 .090 .75 6.0 1.2 -8.0 1/5000 1/2500 10 000 3 3 0.55 4 4 0.45 5 5 0.35 7- 7.5 (7-) 0.30 10 10 0.28 15 15 0.25 20 20 0.25 1/ 400 HZ 115/200 VOLT SYSTEM, TESTED AT 120
9、 5 VOLTS 380-420 HZ 2/ TABLE 2 - DETAIL CALIBRATION REQUIREMENTS NOMINAL AMPERAGE RATING(A) OVERLOAD TRIP TIME IN SECONDS AT PERCENT RATED CURRENT 55 to +85 CAMBIENT EFFECT ON CALIBRATION AT PERCENT RATED CURRENT 200% 500% 1000% +25 C +85 C -55 C115% 145% 100% 145% 115% 170% 2- 1.5 to 50 .15 to 3.0
10、.035 to 0.8MUST HOLD 1HOURMIN MUST TRIP 1 HOUR MAXMUST HOLD 1HOURMIN MUST TRIP 1 HOUR MAXMUST HOLD 1HOURMIN MUST TRIP 1 HOUR MAX3457- 101520AMBIENT TOLERANCE +/-2 C 2/ SEE TABLE 5 FOR ADDITIONAL CALIBRATION PERFORMANCE REQUIREMENTS TABLE 3 - INTERRUPTING CAPACITY (AMPERES) REQUIREMENTS NOMINAL AMPER
11、AGE RATING(A) TEST DESIGNATION PER AS 5692 A B 2- 1000 1000 3457- 101520AEROSPACE STANDARD AS5692/3SHEET 4 OF 6ARC FAULT CIRCUIT BREAKER AIRCRAFT, TRIP FREE, 1 TO 20 AMP, TYPE I TABLE 4 - ENVIRONMENTAL PERFORMANCE MAX. OPERATING ALTITUDE 70 000 FEET INTERMITTENT HIGH TEMPERATURE 115 OC FOR 5 MINUTES
12、 MAXIMUM. (SEE NOTE 13) OPERATING AMBIENT TEMPERATURE RANGE (-)55 oC (+)85 oCVIBRATION IN ACCORDANCE WITH AS5692 SINE - REQUIRED HIGH SINE REQUIRED RANDOM REQUIRED LEVEL D SHOCK 50G, MIL-STD-202, METHOD 213, CONDITION A ACCELERATION 10G TABLE 5 TEST CONDITIONS Minimum Level of Ultimate TripMUST HOLD
13、 OPERATING ALTITUDE TEMP. % RATED CURRENT SIMULATEDCONDITION 15 MINUTES 50 000 FEET (-)55 OC 115% COLD START AND OPERATE30 MINUTES 50 000 FEET (+)80 OC 100% HOT TRANSIENT OPERATION60 MINUTES 50 000 FEET (+)36 OC 100% ALTITUDE HOT OPERATION 2 MINUTES 70 000 FEET (+)49 OC 100% HIGH ALTITUDE TRANSIENT
14、THESE TESTS SHALL BE PERFORMED WITH 36 INCH WIRES CONFORMING TO AS22759/4 OR MS25471 AND TERMINATION AS SPECIFIED BELOW. ALL OTHER TESTS CALLING FOR WIRE LEADS SHALL BE PERFORMED AS SPECIFIED IN AS5692 NOMINAL CURRENT RATING (AMPERES)WIRE SIZE (AWG) INSULATED TERMINAL LUG (MS PART NO.) 2.5 22 MS2503
15、6-103 3 22 -1034 22 -103 5 22 -103 7.5 22 -103 10 20 -10315 18 -103 20 16 -108 REQUIREMENTS: ALL REQUIREMENTS SHALL CONSIST OF THIS SPECIFICATION AND THE LATEST ISSUE OF AS5692 : DESIGN CIRCUIT BREAKERS SHALL BE DESIGNED IN ACCORDANCE WITH FIGURES 1 AND 2 1. ALL QUALIFICATION INSPECTION TESTS REQUIR
16、ED BY AS5692 SHALL BE PERFORMED EXCEPT FOR THE FOLLOWING CHANGES. TABLE V INITIAL QUALIFICATION TESTING SHALL INCLUDE AN ADDITIONAL GROUP WITH 5 SAMPLES OF EACH RATING. EACH OF THESE SAMPLES SUBJECTED TO THE TESTS IN TABLE V AND SHALL NOT BE SUBJECTED TO TEST GROUP I. THESE TESTS SHALL BE PERFORMED
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS569232012ARCFAULTCIRCUITBREAKERCAIRCRAFTTRIPFREE1TO20AMPTYPEI1 自由 航空 故障 电弧 断路器 120 AMPPDF

链接地址:http://www.mydoc123.com/p-1024923.html