SAE AS 1831A-1997 Electrical Power 270 V DC Aircraft Characteristics and Utilization of《飞机用270 V DC电源的特性和使用》.pdf
《SAE AS 1831A-1997 Electrical Power 270 V DC Aircraft Characteristics and Utilization of《飞机用270 V DC电源的特性和使用》.pdf》由会员分享,可在线阅读,更多相关《SAE AS 1831A-1997 Electrical Power 270 V DC Aircraft Characteristics and Utilization of《飞机用270 V DC电源的特性和使用》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970
4、 (outside USA)Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AS1831A AEROSPACESTANDARDAS1831 REV. A Issued 1987-06 Revised 1997-10 Reaffirmed 2017-10 Supersed
5、ing AS1831 Electrical Power, 270 V DC, Aircraft, Characteristics and Utilization of RATIONALE AS1831A has been reaffirmed to comply with the SAE Five-Year Review policy. TABLE OF CONTENTS1. SCOPE . 31.1 Purpose . 32. REFERENCES . 32.1 SAE Publications 33. DEFINITIONS . 34. GENERAL REQUIREMENTS . 64.
6、1 Aircraft Electric Power System 64.1.1 270 V DC Power . 64.1.2 Power Source Impedance . 64.2 Distribution System . 64.3 Utilization Equipment 64.4 Equipment Polarity 65. DETAILED REQUIREMENTS - AIRCRAFT ELECTRICAL POWER SYSTEM 65.1 270 V DC Power System Characteristics . 65.1.1 Steady-State Voltage
7、 65.1.2 Ripple 65.1.3 Transient Voltage 95.1.4 Emergency Power . 95.1.5 Engine Start 9TABLE OF CONTENTS (Continued)6. LOAD DEMAND CONSTRAINTS . 96.1 User Equipment Constraints . 96.1.1 EMC Limits 96.1.2 DC Ripple Current Demand 106.1.3 User Input Current Inrush/Initialization 106.1.4 User Load Deman
8、d and Rate . 106.1.5 User Equipment DC Ground Isolation . 106.1.6 User Equipment AC Ground Isolation . 106.1.7 User Equipment Input/Output Isolation . 106.1.8 Protection of User Equipment . 106.2 Other Electrical System Operation 116.3 Power Requirements Data 117. GROUND SUPPORT EQUIPMENT CHARACTERI
9、STICS 117.1 270 V DC Electric DC Power System Description 117.1.1 Type of Power . 117.1.2 Voltage Sensing 127.2 Power System Characteristics 12FIGURE 1 270 V DC System Transient Voltage Limits . 7FIGURE 2 Frequency Characteristics of Ripple in 270 V DC Electric Systems 8SAE INTERNATIONAL AS1831A Pag
10、e 2 of 12_ 1. SCOPE:This SAE Aerospace Standard (AS) establishes the characteristics and utilization of 270 V DC electric power at the utilization equipment interface and the constraints of the utilization equipment based on practical experience. These characteristics shall be applicable for both ai
11、rborne and ground support power systems. This document also defines the related distribution and installation considerations. Utilization equipment designed for a specific application may not deviate from these requirements without the approval of the procuring activity.1.1 Purpose :The purpose of t
12、his document is to assure compatibility between aircraft electric systems or ground electric systems and airborne utilization equipment. See ARP4729 for recommended practices.2. REFERENCES:The following publications form a part of this document to the extent specified herein. The latest issue of SAE
13、 publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however,
14、 supersedes applicable laws and regulations unless a specific exemption has been obtained.2.1 SAE Publications :Available from SAE, 400 Commonwealth Drive, Warrendale, PA 15096-0001.ARP4729 Document for 270 Voltage Direct Current (270 V DC) System3. DEFINITIONS:3.1 AC CURRENT DEMAND : The AC current
15、 demand is the non-DC component of current drawn by a load.3.2 ABNORMAL OPERATION: Abnormal operation occurs when a malfunction or failure in the electric system has taken place and the protection devices of the system are operating to remove the malfunction or failure from the remainder of the syst
16、em before the limits for abnormal operation are exceeded. The power source may operate in a degraded mode for a defined duration where the power characteristics supplied to the utilization equipment exceed normal operation limits but remain within the limits for abnormal operation, before the protec
17、tion devices are triggered.SAE INTERNATIONAL AS1831A Page 3 of 12_ 3.3 DISTORTION FACTOR : The distortion factor is the ratio of the voltage distortion to steady-state DC voltage.3.4 DISTORTION SPECTRUM: The distortion spectrum quantifies DC distortion in terms of the amplitude of each frequency com
18、po-nent.3.5 DISTRIBUTION SYSTEM : The part of the electrical system used for conveying energy from the point of regulation of the 270 V DC source to the utilization equipment.3.6 EMC (ELECTROMAGNETIC COMPATIBILITY) : EMC is the capability of electronic equipment or systems to be operated in the inte
19、nded operational electromagnetic environment at designed levels of performance while maintaining an acceptable level of emissions and maintaining an acceptable level of susceptibility.3.7 INTERRUPTION SENSITIVE LOADS : Loads that cannot maintain normal operations during power interruptions longer th
20、an 50 s.3.8 NORMAL ELECTRIC SYSTEM OPERATION: Operation of the primary electrical system including all the functional electric system operations required for vehicle operation and mission support in the absence of an electric system failure. These operations occur at any given instant and any number
21、 of times during flight preparation, take-off, airborne conditions, landing, and anchoring. They include all system functions required by all phases of aircraft operation, except during the electric starting of the propulsion engine, when required.3.9 OVERVOLTAGE AND UNDERVOLTAGES: Overvoltage and u
22、ndervoltage are those voltages which exceed the normal limits.3.10 POINT OF REGULATION (POR) : That point in the system where voltage is sensed and referenced for voltage regulation, usually the source side of the 270 V DC bus power contactor.SAE INTERNATIONAL AS1831A Page 4 of 12_ 3.11 RIPPLE: Ripp
23、le is the repetitive variation of voltage above and below the steady-state DC voltage during steady-state electric system operation. Sources of ripple may include, but are not limited to, voltage regulation, stability of the DC power source, commutation/rectification within the DC power source, and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAS1831A1997ELECTRICALPOWER270VDCAIRCRAFTCHARACTERISTICSANDUTILIZATIONOF 飞机 270 VDC 电源 特性 使用 PDF

链接地址:http://www.mydoc123.com/p-1023645.html