SAE ARP 5614-2014 Guidelines for Harness Critical Clamp Locator Marker Installation on Electrical Cable Assemblies《在电缆组件上安装线束关键夹定位标记的指南》.pdf
《SAE ARP 5614-2014 Guidelines for Harness Critical Clamp Locator Marker Installation on Electrical Cable Assemblies《在电缆组件上安装线束关键夹定位标记的指南》.pdf》由会员分享,可在线阅读,更多相关《SAE ARP 5614-2014 Guidelines for Harness Critical Clamp Locator Marker Installation on Electrical Cable Assemblies《在电缆组件上安装线束关键夹定位标记的指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2014 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/ARP5614AEROSPACERECOMMENDED PRACTICEARP5614 Issued 2014-08Guidelines for Harness
5、Critical Clamp Locator Marker Installation on Electrical Cable Assemblies RATIONALE This SAE Aerospace Recommended Practice (ARP) provides information to the user community on the use of Harness Critical Clamp Locator Markers where there is an installation requirement to reduce electrical wiring and
6、 harness movement, provide slack in critical locations and maintain adequate clearance and separation from aircraft equipment and structure. In addition, the Harness Critical Marker alerts the wiring installer and service personnel that harnesses in the area need specialattention.1. SCOPE This ARP s
7、pecifies the recommended methods of marking electrical wiring and harnesses to aid in the positioning/routing of electrical wiring, harnesses and cable assemblies. 1.1 Purpose The purpose of this ARP is to provide guidance on accepted methods for marking electrical wiring and harnesses when control
8、of routing is required for structural clearance, use of service loops, and/or harness movement during ground/flight operations. 1.2 General Primary support of aircraft wiring is provided by metal cushion clamps (such as AS21919 or AS23190) and spaced at intervals not to exceed 24 inches. Harness Cri
9、tical Clamp Locator Markers are used to install the harness in the metal cushioned clamps in specific locations.In areas of minimum clearance and separation aircraft requiring Harness Critical Clamp Locator Markers, electrical wiring and harnesses may require additional support and protection to pre
10、vent chafing, mechanical strain that could lead to arcing and/or damage/breakage to control cables, from associated moving equipment and structure. Preventing interference between electrical wiring, harnesses and equipment that slide or travel by design (shock and vibration mounted equipment or equi
11、pment required to be moved (slide) without being disconnected) is also required. Standard practice methods to prevent chafing are required in addition to primary support not in lieu of primary support. In addition to being supported in areas of minimum clearances and separation requiring Harness Cri
12、tical Clamp Locator Markers, electrical wiring and cable assemblies must also be protected. Shielded or metal braid harnesses may require protective non-metallic covering in the event of loosening or failure of the primary support. SAE INTERNATIONAL ARP5614 Page 2 of 5 2. REFERENCES The following pu
13、blications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purchase order. In the event of conflict between the text of this document and referenc
14、es cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877
15、-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.AS4373 Test Methods for Insulated Electric Wire AS5942 Marking of Electrical Insulating Materials AS50881 Wiring, Aerospace Vehicle AMS-DTL-23053/4 Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Dual-Wall, Ou
16、ter Wall Crosslinked AMS-DTL-23053/5 Insulation Sleeving, Electrical, Heat Shrinkable, Polyolefin, Flexible, Crosslinked AMS-DTL-23053/18 Insulation Sleeving, Electrical, Heat Shrinkable, Modified Fluoropolymer, Crosslinked 2.2 Government Publications Available from DLA Document Services, Building 4
17、/D, 700 Robbins Avenue, Philadelphia, PA 19111-5094, Tel: 215-697-6396, http:/quicksearch.dla.mil/.MIL-HDBK-522 Guidelines for Inspection of Aircraft Electrical Wiring Interconnect Systems A-A-3165 Lacquer, Gloss, For Aircraft Use 2.3 FAA Publications Available from Federal Aviation Administration,
18、800 Independence Avenue, SW, Washington, DC 20591, Tel: 866-835-5322, www.faa.gov.AC 25.1701-1 Certification of Electrical Wiring Interconnection Systems on Transport Category AirplanesAC 43.13-1 Acceptable Methods, Techniques, and Practices - Aircraft Inspection and Repair 3. REQUIREMENTS 3.1 Prote
19、ction and Support Aircraft wiring should be supported to prevent chafing, mechanical strain or work hardening, arcing or overheating, interference between wiring and other components and movement in high vibration areas. Guidance for proper aircraft wiring and harness support can be found in AS50881
20、, MIL-HDBK-522, and FAA AC 25 series and 43.13. SAE INTERNATIONAL ARP5614 Page 3 of 5 3.2 Harness Critical Clamp Locator Marker Location Electrical wiring and harnesses should be permanently marked when there is an installation requirement to control the electrical wiring and cable assembly movement
21、 or slack in critical locations, and maintain specified adequate clearance and separation from equipment and structure. Harness Critical Clamp Locator Markers may be one to two inches wide. Color and location should be specified by the design organization and approved by the procuring activity. When
22、 the clamp is installed over the marker, the marker should be visible on both sides of the clamp, thus ensuring the required harness location in relation to the clamp. When required, clamp locator markers, as a minimum, should be placed at each harness endpoint (i.e., last clamp prior to termination
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP56142014GUIDELINESFORHARNESSCRITICALCLAMPLOCATORMARKERINSTALLATIONONELECTRICALCABLEASSEMBLIES 电缆

链接地址:http://www.mydoc123.com/p-1023146.html