SAE ARP 5369A-2010 Guidelines for Wire Identification Marking Using the Hot Stamp Process《使用热模锻处理的导线识别标记用指南》.pdf
《SAE ARP 5369A-2010 Guidelines for Wire Identification Marking Using the Hot Stamp Process《使用热模锻处理的导线识别标记用指南》.pdf》由会员分享,可在线阅读,更多相关《SAE ARP 5369A-2010 Guidelines for Wire Identification Marking Using the Hot Stamp Process《使用热模锻处理的导线识别标记用指南》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2010 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside US
4、A) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/ARP5369AAEROSPACERECOMMENDEDPRACTICEARP5369 REV. A Issued 1998-11 Reaffirmed 2004-12 Revised 20
5、10-08Superseding ARP5369 Guidelines for Wire Identification MarkingUsing the Hot Stamp Process RATIONALEThe ARP is being updated during the 5 year review to remove reference to inactive standards and introduce reference to new standards. FOREWORDThis SAE Aerospace Recommended Practice (ARP) is inten
6、ded to serve as a guide toward standard practice and is subject to change to keep pace with experience and technical advances. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE ARP5369A Page 2 of 7TABLE OF CONTENTS 1. SCOPE 32. REFERENCES 32.1 Appl
7、icable Documents 32.1.1 SAE Publications . 32.1.2 U.S. Government Publications 32.2 Definitions . 42.3 Symbols and Abbreviations 43. REQUIREMENTS . 43.1 Materials 43.2 Equipment . 43.3 Maintenance 54. QUALITY ASSURANCE PROVISIONS 54.1 Quality Control Inspection . 54.2 Process Qualification Testing .
8、 65. NOTES 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE ARP5369A Page 3 of 71. SCOPE 1.1 These guidelines have been written to provide process information regarding the hot stamp method of marking wire identification directly on aerospace wir
9、es and cables. 1.2 This document is not intended to encourage the use of hot stamp marking or to endorse the related process. This method of marking wire identification is prohibited on any aerospace vehicle wiring that is required to conform to the provisions of AS50881. Methods which do not deform
10、 wire or cable insulation, such as Ink Jet, Dot Matrix or UV Laser marking are encouraged as a means of minimizing the possibility of insulation damage, particularly on insulation constructions of less than 0.010 in wall thickness. AIR5575 provides a comprehensive report on the issue of wire damage
11、than can occur when hot stamp wire marking process is employed. 1.3 In recognition that the present use of hot stamp wire marking is in some operations and may continue for an extended period, the guidelines provided in this document are intended to provide process control information necessary to m
12、inimize the possibility of insulation damage. 2. REFERENCES 2.1 Applicable Documents The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of the other publications shall be the issue in effect o
13、n the date of the purchase order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2.1.1 SAE
14、 Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.AS1241 Fire Resistant Phosphate Ester Hydraulic Fluid For Aircraft AS50881 Wiring, Aerospace Vehicle AS4373 Test Met
15、hods For Insulated Electric Wire ARP5607 Legibility of Print on Aerospace Wires and Cables AIR5575 Hot Stamp Wire marking Concerns for Aerospace Vehicle Applications 2.1.2 U.S. Government Publications Available from Document Automation and production Service (DAPS), Building 4D, 700 Robbins Avenue,
16、Philadelphia, PA 19111-5094, Tel: 215-697-6257, http:/assist.daps.dla.mil/quicksearch/.TT-I-735 Isopropyl Alcohol MIL-PRF-5606 Hydraulic Fluid, Petroleum Base, Aircraft, Missile, and Ordnance MIL-DTL-5624 Turbine Fuel, Aviation, Grade JP-4, JP-5, and JP-5/JP-8 ST MIL-PRF-7808 Lubricating Oil, Aircra
17、ft Turbine Engine, Synthetic Base MIL-DTL-83133 Turbine Fuel, Aviation, Kerosene Types, NATO F-34 (JP-8) and NATO F-35 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SAE ARP5369A Page 4 of 72.2 Definitions HOT STAMP MARKING: Hot stamp marking uses a
18、 heated typeface to transfer pigment from a ribbon or foil to the surfaces of wires or cables. PRESSURE: In the context of this specification, pressure shall be interpreted as the pneumatic air pressure required to provide suitable force to the printhead to obtain acceptable markings. DWELL TIME: Th
19、e specific length of time that is required to mark each individual character on a wire or cable. TEMPERATURE: In the context of this specification, temperature shall be interpreted as the machine setting for the heat applied during the marking process. 2.3 Symbols and Abbreviations UV Ultraviolet ps
20、i Pounds per square inch 3. REQUIREMENTS 3.1 Materials 3.1.1 Foils: A variety of types of marking foils are available from various manufacturers. The type of ribbon or foil to be used for a specific application is generally selected to provide compatibility with the manufacturers marking equipment a
21、nd the wire or cables insulation material and construction. Resistance to abrasion and resistance to aircraft fluids can also vary with the type of foil used. The specific color of identification marking also affects the selection of foil types. Consult your wire marking equipment and foil manufactu
22、rers for product recommendations for specific applications. CAUTION: The foils should be stored in accordance with the foil manufacturers recommendations and not used after the stated shelf life has expired. 3.2 Equipment 3.2.1 Marking Machines: A variety of wire marking machines have been developed
23、 and are in use at various facilities. Each has specific attributes. These machines are generally adjustable in terms of marking temperature, pressure and dwell time. CAUTION: Typewheels, marking type and fixtures must be selected on the basis of the outside diameter, not gauge, of the wire to be pr
24、inted. The proper selection and sizing of these items is critical to achieving maximum efficiency of the printer with a minimum of insulation penetration. It is not recommended that the Hot stamp process be used on wire with outside diameters of less than 0.035 in. 3.2.2 Adjustments: Consult your wi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEARP5369A2010GUIDELINESFORWIREIDENTIFICATIONMARKINGUSINGTHEHOTSTAMPPROCESS 使用 热模锻 处理 导线 识别 标记 指南 PDF

链接地址:http://www.mydoc123.com/p-1023063.html