SAE AIR 6202-2012 Test Cell Mass Fuel Flow Measurement Using Coriolis Flow Meters《使用科里奥利流量计进行的试验室质量燃料流量测量》.pdf
《SAE AIR 6202-2012 Test Cell Mass Fuel Flow Measurement Using Coriolis Flow Meters《使用科里奥利流量计进行的试验室质量燃料流量测量》.pdf》由会员分享,可在线阅读,更多相关《SAE AIR 6202-2012 Test Cell Mass Fuel Flow Measurement Using Coriolis Flow Meters《使用科里奥利流量计进行的试验室质量燃料流量测量》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、 _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising ther
2、efrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2017 SAE International All rights reserved. No part of this
3、publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-49
4、70 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/standards.sae.org/AIR6202 AEROSPACE INFORMATION REPORT AIR6202 Issued 2012-04 Reaffirmed 2017-06 Test Cell Mass
5、Fuel Flow Measurement Using Coriolis Flow Meters RATIONALE AIR6202 has been reaffirmed to comply with the SAE Five-Year Review policy. TABLE OF CONTENTS 1. SCOPE 2 2. APPLICABLE DOCUMENTS 2 2.1 SAE Publications . 2 2.2 ASTM Publications 2 3. INTRODUCTION AND BENEFITS . 2 4. PRINCIPLE OF OPERATION .
6、3 5. BEST PRACTISE ADVICE FOR MECHANICAL CONFIGURATION/INSTALLATION SINGLE METER (LIQUID) 4 6. BEST PRACTISE ADVICE FOR MECHANICAL CONFIGURATION/INSTALLATION SINGLE METER (GAS) 6 7. BEST PRACTISE ADVICE FOR MECHANICAL CONFIGURATION/INSTALLATION TWIN METERS (LIQUID) . 7 8. MANAGEMENT OF “ZERO DRIFT“
7、. 8 9. INITIAL AND PERIODIC CALIBRATION REQUIREMENTS . 9 10. NOTES 9 1. SCOPE The scope of this information report applies to the steady state measurement of direct mass fuel flow in gas turbine engine test cells. A measurement accuracy, and hence uncertainty of between 0.1 to 0.2% of value is belie
8、ved to be achievable for liquid flow applications with some meter models/installations. Whilst capable of general transient measurement in 50 to 100 Hz region, this type of fuel meter is not capable of rapid transient measurement (in 100 to 250 Hz region). It is also not currently considered suitabl
9、e for “in flight“ fuel flow measurement. 2. APPLICABLE DOCUMENTS The following publications form a part of this document to the extent specified herein. The latest issue of SAE publications shall apply. The applicable issue of other publications shall be the issue in effect on the date of the purcha
10、se order. In the event of conflict between the text of this document and references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 2.1 SAE Publications Available fr
11、om SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. AIR5026 Test Cell Instrumentation ARP4990 Turbine Flowmeter Fuel Flow Calculations AS5304 Standard Specification for Turbine Flowmeters 2.2 A
12、STM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org. ASTM D1250 Standard Guide for Petroleum Measurement Tables 3. INTRODUCTION AND BENEFITS Traditionally, test cell mass fuel flow measurement for
13、 gas turbine engines has been calculated following the measurement of multiple parameters that include volumetric fuel flow, density and temperature(s). This includes measuring the temperature of fuel at both the meter during flow and a static sample of the fuel used, in order to correct “real time“
14、 meter density relative to the static sample in accordance with ASTM D1250. In some cases, “on line“ densimeters are used. Also, there are other elements to consider in the measurement uncertainty chain “stack up“ when using this traditional volumetric fuel flow measurement method, such as viscosity
15、 and pressure, particularly when using turbine flowmeters (see ARP4990). The total measurement uncertainty for the volumetric fuel flow measurment method is believed to be in the region of 0.25 to 0.5% of value depending on the meter choice, installation, range and method being used. This accuracy i
16、s only likely to be achieved over the top 80% (5/1 turn down ratio) of range of a single application flow meter. Below this range there is likely to be a significant increase in measurement uncertainty. Typically, turbine flow meters have been used in the US and positive displacement bulk meters use
17、d in the UK. SAE INTERNATIONAL AIR6202 Page 2 of 9_ The development of Coriolis fuel meters over the last 20 years has seen significant improvments in accuracy capability from 1.0 to 0.1% of value, by some manufacturers. When taking temperature compensation into account over a realistic working rang
18、e, a total uncertainty of approximately 0.2% of value is considered to be more realistic for liquid flow applications. This accuracy can be achieved over the top 95% of range (20/1 turn down ratio) of a single application flow meter. Below this range there is likely to be a significant increase in m
19、easurement uncertainty. The use of Coriolis fuel meters enables the direct measurement of mass fuel flow as a single parameter rather than multiple parameters and corrections that are described above, and is also likely to have additional cost benefits to the overall measurement system with the remo
20、val of these measurements/routines. Also, there are no moving parts to this design of meter requiring less overhaul maintenance throughout its life. These meters can also be used to measure gas flow, although it should be noted that the measurement accuracy capability is likely to be worse (typicall
21、y 0.3 to 0.4% of value). Some manufacturers also provide the ability for their meters to output density or volumetric flow if required. Two features of concern with this design are the management of the mechanical installation configuration (which is known to have sensitivity issues) and the risk of
22、 zero drift, particularly with ambient temperature variation. These issues and the principle of operation are covered in the following sections of this document. 4. PRINCIPLE OF OPERATION FIGURE 1 Drive Coil & Magnet Inlet Pickoff Outlet Pickoff No Flow Flow Flow Tubes SAE INTERNATIONAL AIR6202 Page
23、 3 of 9_ The illustration above highlights a curved double flow tube type configuration, a configuration that has been proven to be able to achieve the measurement accuracies/uncertainties that are quoted in the previous section. Other configurations, such as single and straight tubes can also be us
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR62022012TESTCELLMASSFUELFLOWMEASUREMENTUSINGCORIOLISFLOWMETERS 使用 科里奥利 流量计 进行 试验室 质量 燃料 流量 测量 PDF

链接地址:http://www.mydoc123.com/p-1020372.html