SAE AIR 1898A-1998 Maintenance of Batteries and Battery Charging and Servicing Facilities《电池和电池充电与维修设施的维护》.pdf
《SAE AIR 1898A-1998 Maintenance of Batteries and Battery Charging and Servicing Facilities《电池和电池充电与维修设施的维护》.pdf》由会员分享,可在线阅读,更多相关《SAE AIR 1898A-1998 Maintenance of Batteries and Battery Charging and Servicing Facilities《电池和电池充电与维修设施的维护》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.”SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions.Copyright 2015 SAE InternationalAll rights reserved. No part of this publi
3、cation may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE.TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada)Tel: +1 724-776-4970 (out
4、side USA)Fax: 724-776-0790Email: CustomerServicesae.orgSAE WEB ADDRESS: http:/www.sae.orgSAE values your input. To provide feedbackon this Technical Report, please visithttp:/www.sae.org/technical/standards/AIR1898AAEROSPACEINFORMATION REPORTAIR1898REV. AIssued 1992-06Revised 1998-12Reaffirmed 2015-
5、10Superseding AIR1898Maintenance of Batteries and Battery Charging and Servicing FacilitiesRATIONALEAIR1898A has been reaffirmed to comply with the SAE five-year review policy.1. SCOPE:This SAE Aerospace Information Report (AIR) covers, and is restricted to, hands-on servicing/maintenance of industr
6、ial lead acid batteries used solely for motive power and exclusively for ground support equipment (GSE). It does not address or pertain to automotive-type SLI (starting-lighting-ignition) batteries or any other types of batteries (such as nickel-cadmium, zinc, or lithium batteries) which may be on-b
7、oard airport GSE for either motive power or auxiliary uses. Similarly, the battery servicing and charging facilities described herein are those intended exclusively for industrial lead acid batteries.1.1 Purpose:This AIR is intended to provide basic information on proper procedures and facilities fo
8、r handling, charging, and otherwise servicing and maintaining motive power lead acid batteries used in airport GSE. Adherence to these guidelines can help maximize battery life and performance, as well as the overall efficiency and effectiveness of electric GSE at airports. This document also descri
9、bes (physical) battery servicing facilities in the airport environment.2. REFERENCES:1. “Standards for Deep Cycle Battery Chargers” BCI-I-4 Battery Council Int. Standard. “Material Handling (Industrial Truck) Battery Chargers” Standards Publication PV6 1976 and “Determination of Capacity of Lead Aci
10、d Industrial Storage Batteries for Motive Power Service,” Standard Publication IB 2 1974 National Electrical Manufacturers Association, Washington, D.C.2.1 Applicable Documents:This document is based on, and should be both complemented and supplemented by, the detailed instructions/recommended pract
11、ices and procedures of the manufacturers and/or suppliers of batteries, chargers, vehicles, and servicing/maintenance facility components. Similarly, this document should be considered in the context of applicable federal, state, and local health, safety, fire, and other pertinent regulations, which
12、 are predominant. In particular, Occupational Safety and Health Administration (OSHA) Regulations 1926.403 and 1910.178 specify the federal requirements concerning safe care and charging of storage batteries.2.2 Definitions:The following words and terms are most often associated with industrial lead
13、 acid batteries, and should be familiar to personnel responsible for proper battery maintenance:AMPERE (AMP or A): A unit of measurement of electrical current. The current forced through a resistance of 1 by a potential of 1 V is equal to 1 A.AMPERE-HOUR (Ah) CAPACITY: Ampere-Hour capacity is the nu
14、mber of ampere-hours which a storage battery can deliver under specified conditions such as temperature, rate of discharge, and final voltage.NOTE: For the purpose of this standard, ampere-hour capacity is determined by a 6 h rate discharge cycle.CONNECTORS: Molded strips of lead that connect the po
15、sts over the top of the cover, where multi-ple cells are used.CURRENT: The flow of electricity, normally expressed in amperes.CYCLE: The cycle of a storage cell or battery is the discharge and subsequent charge of the cell or battery to restore the initial conditions. Life cycle or useful life is th
16、e number of times a battery can be discharged-charged before it fails to deliver a minimum of 80% of its rated 6 h capacity.DEEP DISCHARGE: Removal of up to 80% of the rated capacity of the battery; in practice, it is sug-gested that a maximum 80% depth-of-discharge be considered the maximum deep di
17、scharge level of a battery, even if it is rated at 100% discharge.DIRECT CURRENT (DC): A direct current is a unidirectional current in which the changes in value are either zero or so small that they may be neglected.ELECTROLYTE (Component of a Cell): An electrolyte is a conducting medium in which t
18、he flow of electric current takes place by the migration of ions. (The electrolyte for a lead-acid storage cell is an aqueous solution of sulfuric acid.)SAE INTERNATIONAL AIR1898A 2 OF 122.2 (Continued):ENERGY DENSITY: The ratio of battery energy content in watt-hours to battery weight or volume.HYD
19、ROMETER: An instrument used to measure electrolyte density or specific gravity.KILOWATT-HOUR (kWh) Watthour Capacity 1000: The number of watt-hours that can bedelivered under specified conditions as to temperature, rate of discharge, and final voltage.RATED CAPACITY: The rated capacity of a storage
20、battery is the number of ampere-hours and/or watt-hours which it is capable of delivering when fully charged and under specified conditions oftemperature, rate of discharge, final voltage, and specific gravity.SPECIFIC GRAVITY (of Electrolyte): The specific gravity of an electrolyte is the ratio of
21、the weight of a given volume of electrolyte to the weight of an equal volume of water at a specified temperature.VOLT (V): A unit of electromotive force; each battery cell produces approximately 2 V.VOLTMETER: An instrument for measuring battery cells voltage output.WATT (W) (1) (General): The unit
22、of power in the International System of units (SI). The Watt is the power required to do work at the rate of 1 joule per second.WATT-HOUR (Wh): The measure of energy or work accomplished; the product of the rate of work in watts and the time in hours, or the product of ampere-hours x average voltage
23、.3. LIMITATIONS:This document is intended as a basic battery maintenance guideline only, and should not supersede battery or charger manufacturers detailed installation, handling, charging, and maintenance instructions. Service-related problems with batteries, chargers, vehicles, and components that
24、 cannot be solved on the job or in on-site maintenance shops should be referred to the manufacturers or their authorized representatives.4. GENERAL BACKGROUND:Battery-powered, or electric, GSE is utilized throughout the world by major passenger airlines, regional carriers, fixed-base operators (FBOs
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEAIR1898A1998MAINTENANCEOFBATTERIESANDBATTERYCHARGINGANDSERVICINGFACILITIES 电池 充电 维修 设施 维护 PDF

链接地址:http://www.mydoc123.com/p-1020087.html