1、*USACE / NAVFAC / AFCEC / NASA UFGS-33 77 19.00 40 (August 2013)-Preparing Activity: NASA SupersedingUFGS-33 77 19.00 40 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2013*SECTION TABLE OF CONTENTSDIVISION 33 - UTILITIESSECTION 33 77 19.00 40MED
2、IUM-VOLTAGE GAS SWITCH08/13PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 PREDICTIVE TESTING AND INSPECTION TECHNOLOGY REQUIREMENTS1.4 MAINTENANCE MATERIALS SUBMITTALSPART 2 PRODUCTS2.1 EQUIPMENT2.1.1 Switches2.1.2 Space Heaters2.1.3 Mounting Frames2.2 ACCESSORIES2.3 FACTORY FINISH2.4 TESTS INSPECTIO
3、NS, AND VERIFICATIONS2.4.1 Factory Information2.4.2 ShippingPART 3 EXECUTION3.1 INSTALLATION3.1.1 Coordination3.1.2 Grounding3.2 FIELD TESTING- End of Section Table of Contents -SECTION 33 77 19.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS
4、-,-,-*USACE / NAVFAC / AFCEC / NASA UFGS-33 77 19.00 40 (August 2013)-Preparing Activity: NASA SupersedingUFGS-33 77 19.00 40 (August 2010)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2013*SECTION 33 77 19.00 40MEDIUM-VOLTAGE GAS SWITCH08/13*NOTE: This guid
5、e specification covers the requirements for the requirements for 5k through 38 kV, 600A load-break sulphur hexafluoride (SF6) gas switches. On drawings, indicate subsurface, vault, pad-mount, indoor, metal-enclosed, or pole mounted type; the number of switched ways; separable connections; and single
6、-side, double-side, floor, wall, ceiling, or other type installation.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific require
7、ments by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide spec
8、ification are welcome and should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL*NOTE: If Section 26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS is not included in the project specification, insert applicable requirements therefrom and delete the following paragraph.*Section 2
9、6 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS, and Section26 05 70.00 40 HIGH VOLTAGE OVERCURRENT PROTECTIVE DEVICES and Section 26 05 71.00 40 LOW VOLTAGE OVERCURRENT PROTECTIVE DEVICES apply to work specified in this section.SECTION 33 77 19.00 40 Page 2Provided by IHSNot for ResaleNo repro
10、duction or networking permitted without license from IHS-,-,-1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designa
11、tion, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in
12、the text are automatically deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the ba
13、sic designation only.AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ANSI C37.72 (1987) Standard for Manually-Operated Dead-Front Pad Mounted Switchgear with Load Interrupting Switches and Separable Connections for Alternating-Current SystemsASTM INTERNATIONAL (ASTM)ASTM A123/A123M (2012) Standard Speci
14、fication for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM A153/A153M (2009) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel HardwareASTM D2472 (2000; R 2006) Standard Specification for Sulphur HexafluorideINSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEE
15、E)IEEE 386 (2006; INT 1 2011) Standard for Separable Insulated Connector Systems for Power Distribution Systems Above 600VIEEE C57.12.28 (2005; INT 3 2011) Standard for Pad-Mounted Equipment - Enclosure IntegrityNATIONAL AERONAUTICS AND SPACE ADMINISTRATION (NASA)RCBEA GUIDE (2004) NASA Reliability
16、Centered Building SECTION 33 77 19.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-and Equipment Acceptance Guide1.2 SUBMITTALS*NOTE: Review Submittal Description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the foll
17、owing list to reflect only the submittals required for the project.The Guide Specification technical editors have designated those items that require Government approval, due to their complexity or criticality, with a “G.“ Generally, other submittal items can be reviewed by the Contractors Quality C
18、ontrol System. Only add a “G” to an item, if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, use a code of up to three characters within the submittal tags following the “G“ designation to indicate the approv
19、ing authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes followi
20、ng the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ de
21、signation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that reviews the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-02 Shop DrawingsCon
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS33771900402013MEDIUMVOLTAGEGASSWITCHPDF

链接地址:http://www.mydoc123.com/p-1019673.html