REG UFGS-26 56 19 00 40-2013 ROADWAY LIGHTING.pdf
《REG UFGS-26 56 19 00 40-2013 ROADWAY LIGHTING.pdf》由会员分享,可在线阅读,更多相关《REG UFGS-26 56 19 00 40-2013 ROADWAY LIGHTING.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-26 56 19.00 40 (May 2013)-Preparing Activity: NASA SupersedingUFGS-26 56 19.00 40 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2013*SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 56 19.00 40R
2、OADWAY LIGHTING05/13PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 ADMINISTRATIVE REQUIREMENTSPART 2 PRODUCTS2.1 SYSTEM DESCRIPTION2.2 STREET-LIGHTING LUMINAIRES2.2.1 Roadway Luminaire Components2.2.2 End-Mounted High-Intensity-Discharge (HID) Luminaires2.2.3 Side-Mounted (HID) Luminaires2.2.4 Lamp B
3、allasts2.2.4.1 Multiple-Circuit Ballasts2.2.4.2 Series Circuit Transformers2.2.5 Lamps2.2.5.1 (HID) Lamps and Ballasts2.2.5.2 Low Pressure Sodium2.2.6 Side-Mounted Incandescent Luminaires2.2.7 Incandescent LampsPART 3 EXECUTION3.1 INSTALLATION3.1.1 End-Mounted High-Intensity-Discharge (HID) Luminair
4、es3.1.2 Side-Mounted (HID) Luminaires3.1.3 Side-Mounted Incandescent Luminaires3.2 FIELD TESTING- End of Section Table of Contents -SECTION 26 56 19.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-26 5
5、6 19.00 40 (May 2013)-Preparing Activity: NASA SupersedingUFGS-26 56 19.00 40 (November 2008)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2013*SECTION 26 56 19.00 40ROADWAY LIGHTING05/13*NOTE: This guide specification covers the requirements for highway an
6、d roadway lighting luminaires.Drawings should show details of each street lighting fixture with letter designation keyed to the drawings and electrical symbols describing the type, style, class, kind, and size of fixture as follows:Roadway lighting fixtures including luminaires for IES as listed in
7、IES RP-8, “Lighting Distribution Patterns.“Coordinate this section with UFGS Section 26 09 23.00 40 LIGHTING CONTROL DEVICES and UFGS Section 26 56 13.00 40 LIGHTING POLES AND STANDARDS.Roadway-lighting standards and fixture details on drawings should describe, in plan and elevation, the type and ki
8、nd of pole, bracket, luminaire, base, and foundation required for installation at the location indicated. Elevation details should indicate height of pole, bracket-spread length, luminaire, depth of foundation, anchor bolts, underground conduit connections, ground rods, and ground connections. Plan
9、views should indicate foundation configuration, conduit stub-ups, base dimensions, and bolt circles. Foundation detail drawings should accurately describe the nature and properties of soil surrounding foundations for the support of lighting standards.Foundations for installation of area, flood light
10、ing, roadway lighting, and security lighting standards and fixtures in filled locations may require modification to resist horizontal movement without permanent set under stipulated wind loads.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this gui
11、de specification or preparing new project SECTION 26 56 19.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For
12、bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as
13、a Criteria Change Request (CCR).*NOTE: TO DOWNLOAD UFGS GRAPHICSGo to http:/www.wbdg.org/ccb/NAVGRAPH/graphtoc.pdf.*NOTE: This section contains the following sketches (Graphics) and are available in metric (SI) and U.S. Customary (IP) system dimensions. Sketch titles and style numbers are unchanged
14、for both types. The metric values indicated are a conversion of U.S. Customary (IP) system dimensions.Do not include list of sketches, or sketches themselves, in project specifications. Use luminaire sketches as details on drawings whenever possible. If special features are required, do not modify s
15、ketches, but indicate these changes as notes in fixture schedule. The “XL“ style numbers and dates should remain on the drawing details.Sketch No. TitleXL-1 Roadway and Area LightXL-4 Roadway and Area LightXL-6 Area and Street Lighting Cutoff LuminaireXL-13 thru 19 Reserved for Future Exterior Lumin
16、airesNOTE: Do not include this index in project specification.*NOTE: Show the following information on the drawings or specify in the project specifications:a. Luminaire schedule and indicate pertinent information; i.e., mounting, lamps, ballasts, and voltage.1. Type of luminaire;2. Voltage, wattage
17、, and frequency rating required;SECTION 26 56 19.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3. Accessories required, such as photocell, time switches, and auxiliary lamps;4. Location of poles or standards;5. Referenced sketch; and6.
18、Extent and location of the work to be accomplished and wiring and equipment necessary for a complete installation.*NOTE: Demolition work that involves disposal of fluorescent and HID lamps and ballasts requires the use of Section 02 84 16 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs AND M
19、ERCURY.*PART 1 GENERAL*NOTE: If Section 26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS is not included in the project specification, applicable requirements there from should be inserted and the following paragraph deleted.*Section 26 00 00.00 20 BASIC ELECTRICAL MATERIALS AND METHODS applies
20、 to work specified in this section.1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use
21、the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text automatically be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS26561900402013ROADWAYLIGHTINGPDF