REG UFGS-26 56 13 00 40-2008 LIGHTING POLES AND STANDARDS.pdf
《REG UFGS-26 56 13 00 40-2008 LIGHTING POLES AND STANDARDS.pdf》由会员分享,可在线阅读,更多相关《REG UFGS-26 56 13 00 40-2008 LIGHTING POLES AND STANDARDS.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-26 56 13.00 40 (November 2008)-Preparing Activity: NASA Superseding(New)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2008*SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 56 13.00 40LIGHTING POLES AND STAND
2、ARDS11/08PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Drawing Requirements1.4.1.1 Poles1.4.2 Pressure Treated Wood Pole Quality1.4.2.1 Wood Crossarms1.4.3 Tests for Fiberglass Poles1.4.4 Regulatory Requirements1.4.5 Standard Products1.4.5.1 Alternative Qualific
3、ations1.4.5.2 Material and Equipment Manufacturing Date1.4.6 Pre-Installation Conference1.5 DELIVERY, STORAGE, AND HANDLING1.5.1 Wood Poles1.5.2 Concrete Poles1.5.3 Fiberglass Poles1.5.4 Aluminum Steel Poles1.6 SUSTAINABLE DESIGN REQUIREMENTS1.6.1 Local/Regional Materials1.6.2 Environmental Data1.7
4、WARRANTY1.8 OPERATIONAL SERVICEPART 2 PRODUCTS2.1 PRODUCT COORDINATION2.2 LIGHTING STANDARDS2.3 POLES2.3.1 Concrete Poles2.3.1.1 Steel Reinforcing2.3.1.2 Tensioned Reinforcing2.3.1.3 Coating and Sleeves for Reinforcing MembersSECTION 26 56 13.00 40 Page 1Provided by IHSNot for ResaleNo reproduction
5、or networking permitted without license from IHS-,-,-2.3.1.4 Strength Requirement2.3.1.5 Shaft Preparation2.3.2 Aluminum Poles2.3.2.1 Finish2.3.2.2 Grounding Connection Provisions2.3.2.3 Ground Rods2.3.2.4 Top Cover and Bases2.3.2.5 Transformer Base2.3.2.6 Transport and Handling Protection2.3.3 Stee
6、l Poles2.3.3.1 Pole Mounting2.3.3.2 Accessories2.3.3.3 Pole Markings2.3.3.4 Steel Standard Finish2.3.4 Wood Poles2.3.5 Fiberglass Poles2.4 BRACKETS AND SUPPORTS2.4.1 Concrete Standard Detachable Brackets2.5 POLE LINE HARDWARE2.5.1 Series Roadway Lighting Insulators2.6 FOUNDATIONS FOR LIGHTING STANDA
7、RDS2.6.1 Concrete Foundations2.6.1.1 Anchor BoltsPART 3 EXECUTION3.1 INSTALLATION3.1.1 Wood Poles3.1.2 Concrete Poles3.1.3 Fiberglass Poles3.1.4 AluminumSteel Poles3.2 INSTALLATION OF STANDARD FOUNDATIONS3.2.1 Excavation3.2.2 Formwork3.2.3 Setting of Anchor Bolts3.2.4 Concrete Placement3.3 SPECIAL F
8、OUNDATIONS3.3.1 Power-Installed Screw Foundations3.4 STANDARD SETTING3.5 GROUNDING3.5.1 Ground Rods and Pole Butt Electrodes3.5.2 Items to be Grounded3.5.3 Lighting Pole3.5.4 Handhole3.5.5 Metal Cable Boxes3.5.6 Ground Resistance Measurements3.5.7 Record Drawings- End of Section Table of Contents -S
9、ECTION 26 56 13.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-26 56 13.00 40 (November 2008)-Preparing Activity: NASA Superseding(New)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreemen
10、t with UMRL dated October 2008*SECTION 26 56 13.00 40LIGHTING POLES AND STANDARDS11/08*NOTE: This specification covers the requirements for lighting poles, standards, and related mounting accessories for exterior lighting, including, but not limited to, area lighting, flood lighting, roadway lightin
11、g, and security lighting systems.Use UFGS Section 26 09 23.00 40 LIGHTING CONTROL DEVICES for control devices (includes tailoring for exterior lighting).Use UFGS Section 26 55 53.00 40 SECURITY LIGHTING for security and closed circuit television CCTV special lighting.Use UFGS Section 26 56 19.00 40
12、ROADWAY LIGHTING for roadway and street lighting.Use UFGS Section 26 56 23.00 40 AREA LIGHTING for general exterior lighting.Use UFGS Section 26 55 36.00 40 FLOOD LIGHTING for specific facility exterior illumination requirements.Edit this guide specification for project specific requirements by addi
13、ng, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be
14、 directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*SECTION 26 56 13.00 40 Page 3Provided
15、by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*NOTE: TO DOWNLOAD UFGS GRAPHICSGo to http:/www.wbdg.org/ccb/NAVGRAPH/graphtoc.pdf.*NOTE: This section contains the following sketches (Graphics) and are available in metric (SI) and U.S. Customary (IP) system d
16、imensions. Sketch titles and style numbers are unchanged for both types. The metric values indicated are a conversion of U.S. Customary (IP) system dimensions.Do not include list of sketches, or sketches themselves, in project specifications. Use luminaire sketches as details on drawings whenever po
17、ssible. If special features are required, do not modify sketches, but indicate these changes as notes in fixture schedule. The “XL“ style numbers and dates should remain on the drawing details.Sketch No. TitleXL-20 Round Fiberglass Pole, Direct Set Tenon MountXL-21 Round Fiberglass Pole, Direct Set
18、Mast Arm MountXL-22 Round Concrete Pole, Direct Set Tenon MountXL-23 Round Concrete Pole, Direct Set Mast Arm MountXL-24 Round Steel Pole, Direct Set Tenon MountXL-25 Round Steel Pole, Direct Set Mast Arm MountXL-26 Round Steel Pole, Anchor Base, Tenon MountXL-27 Round Steel Pole, Anchor Base, Mast
19、Arm MountXL-28 Luminaire Mounting BracketsXL-29 Various Luminaire Mounting Arm TypesXL-30 Miscellaneous Luminaire Mounting BracketsXL-31 Luminaire Mounting ArmsXL-32 Luminaire Mounting ArmsXL-33 Bolt-Down Pole FoundationXL-34 Grounding Installation Details for Direct Set PolesNOTE: Do not include th
20、is index in project specification.*NOTE: Show the following information on the drawings or specify in the project specifications:a. Luminaire schedule and indicate pertinent information; i.e., mounting, lamps, ballasts, and voltage.1. Type of luminaire;2. Voltage, wattage, and frequency rating requi
21、red;3. Accessories required, such as photocell, time switches, and auxiliary lamps;SECTION 26 56 13.00 40 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4. Location of poles or standards;5. Referenced sketch; and6. Extent and location of the w
22、ork to be accomplished and wiring and equipment necessary for a complete installation.*NOTE: Demolition work that involves disposal of fluorescent and HID lamps and ballasts will require the use of Section 02 84 16 HANDLING OF LIGHTING BALLASTS AND LAMPS CONTAINING PCBs AND MERCURY.*PART 1 GENERAL1.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS26561300402008LIGHTINGPOLESANDSTANDARDSPDF

链接地址:http://www.mydoc123.com/p-1019662.html