1、*USACE / NAVFAC / AFCESA / NASA UFGS-26 51 00.00 40 (February 2013)-Preparing Activity: NASA SupersedingUFGS-26 51 00.00 40 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2013*SECTION TABLE OF CONTENTSDIVISION 26 - ELECTRICALSECTION 26 51 00
2、.00 40INTERIOR LIGHTING02/13PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.3 ADMINISTRATIVE REQUIREMENTS1.3.1 Pre-Installation Meetings1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Lighting Fixtures, Complete with Lamps and Ballasts1.5.2 Regulatory Requirements1.5.3 Standard Products1.5.3.1 Alternative Qua
3、lifications1.5.3.2 Material and Equipment Manufacturing Date1.5.4 Sustainable Design Requirements1.5.4.1 Local/Regional Materials Documentation1.5.4.2 Environmental Data1.5.5 Energy Efficiency Data1.6 WARRANTY1.6.1 Electronic Ballast WarrantyPART 2 PRODUCTS2.1 DESIGN REQUIREMENTS2.2 COMPONENTS2.2.1
4、Fluorescent Lighting Fixtures2.2.1.1 Fluorescent Lamp Electronic Ballasts2.2.1.2 Fluorescent Lamp Electronic Dimming Ballast2.2.1.3 Fluorescent Electromagnetic Ballasts2.2.1.4 Fluorescent Lamps2.2.1.5 Compact Fluorescent Fixtures2.2.1.6 Open-Tube Fluorescent Fixtures2.2.1.7 Air Handling Fixtures2.2.
5、1.8 Electromagnetic Interference Filters2.2.2 High-Intensity-Discharge (Hid) Lighting Fixtures2.2.2.1 HID Ballasts2.2.2.2 High-Pressure Sodium (HPS) LampsSECTION 26 51 00.00 40 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-2.2.2.3 Low-Pressur
6、e Sodium Lamps2.2.2.4 Metal-Halide Lamps2.2.3 Incandescent Lighting Fixtures2.2.3.1 Incandescent Lamps2.2.4 Commercial Incandescent Lighting Fixtures2.2.4.1 Surface-Mounted Fixtures2.2.4.2 Recessed Fixtures2.2.4.3 Pendant-Mounted Fixtures2.2.5 Industrial Incandescent Lighting Fixtures2.2.6 Enclosed
7、And Gasketed Vapor-Tight Fixtures2.2.7 Incandescent Lamps2.2.8 Recess- And Flush-Mounted Fixtures2.2.9 Suspended Fixtures2.2.10 Fixtures For Hazardous Locations2.3 EQUIPMENT2.3.1 Equipment Identification2.3.1.1 Manufacturers Nameplate2.3.1.2 Labels2.3.2 Power Hook Fixture Hangers2.3.3 Auxiliary Inst
8、ant-On System2.3.4 Support Hangers for Lighting Fixtures in Suspended Ceilings2.3.4.1 Wires2.3.4.2 Wires, for Humid Spaces2.3.4.3 Straps2.3.4.4 Rods2.3.5 Factory Applied Finish2.4 ACCESSORIES2.4.1 Lowering Devices For High-Bay Lighting Fixtures2.4.1.1 Contact Assembly2.4.1.2 Lockbox2.4.1.3 Cable/Cha
9、inPART 3 EXECUTION3.1 PREPARATION3.1.1 Field Applied Painting3.2 INSTALLATION3.2.1 Lamps3.2.2 Lighting Fixtures3.2.3 Suspended Fixtures3.2.4 Ballasts3.2.4.1 Remote Ballasts3.2.4.2 Electronic Dimming Ballasts3.3 FIELD QUALITY CONTROL3.3.1 Electronic Dimming Ballast3.4 FIELD TESTING3.5 MAINTENANCE3.5.
10、1 Operational Service- End of Section Table of Contents -SECTION 26 51 00.00 40 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-26 51 00.00 40 (February 2013)-Preparing Activity: NASA SupersedingUFGS-26 51 0
11、0.00 40 (February 2011)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated January 2013*SECTION 26 51 00.00 40INTERIOR LIGHTING02/13*NOTE: This guide specification covers requirements for interior lighting installations. Requirements for materials and procedures for sp
12、ecial or unusual design should be added as necessary to fit specific projects.Emergency lighting and exit signs are covered in Section 26 52 00.00 40 EMERGENCY LIGHTING. Lighting control devices are covered in the Section 26 09 23.00 40 LIGHTING CONTROL DEVICES.Adhere to UFC 1-300-02 Unified Facilit
13、ies Guide Specifications (UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appr
14、opriate information.Remove information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: In compliance with
15、Executive Order 12902 and FAR section 23.704 which directs federal agencies to purchase products in the upper 25 percent of energy efficiency, the following products specified in this section meet or exceed the U.S. Department of Energy, Federal Energy Management Program (DOE/FEMP) Product Energy Ef
16、ficiency Recommendations (PEER) for the Recommended energy efficiency levels.This specification contains products recommended by FEMP. The following recommendations are currently SECTION 26 51 00.00 40 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IH
17、S-,-,-on the FEMP site on the internet. Additional recommendations may be added or existing recommendations updated at any time.FEMP LT-1 (1998) How to Buy Energy EfficientFluorescent Tube LampsFEMP LT-2 (2000) How to Buy Energy-EfficientFluorescent BallastsTo view the latest on-line information abo
18、ut buying energy efficient products go to the FEMP home page at: http:/www1.eere.energy.gov/femp/technologies/procuring_eeproducts.html*NOTE: TO DOWNLOAD UFGS GRAPHICSGo to http:/www.wbdg.org/ccb/NAVGRAPH/graphtoc.pdf.*NOTE: This site contains lighting fixture sketches (Graphics) and are available i
19、n metric (SI) and U.S. Customary (IP) system dimensions. Sketch titles and style numbers are unchanged for both types. The metric values indicated are a conversion of the IP system dimensions.Do not include list of sketches, or sketches themselves, in project specifications. Use lighting fixture ske
20、tches as details on drawings whenever possible. If special features are required for a project, do not modify sketches, but indicate these changes on notes in fixture schedule. The “NL“ style numbers and dates should remain on the drawing details.*NOTE: Show the following information on project draw
21、ings:1. Type, style, mounting, and lamp arrangement2. Location of fixtures3. Wattage, voltage, and frequency rating required4. Type of reflector, diffuser required5. Glass/plastic lens6. Accessories required, such as photocell, time switches, sensors, and auxiliary lamps7. Mounting height above floo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGUFGS26510000402013INTERIORLIGHTINGPDF