1、Lessons Learned Entry: 0435Lesson Info:a71 Lesson Number: 0435a71 Lesson Date: 1996-07-17a71 Submitting Organization: JPLa71 Submitted by: J.A. RobertsSubject: Ground Support Equipment Failure Caused Damage to SEASAT-A (1978) Abstract: A SEASAT-A subassembly was damaged during thermal-vacuum test du
2、e to the configuration of GSE test equipment. A reed relay in a commercial data scanner was connected to circuits requiring +5 volts; its failure permitted the SEASAT-A circuits to be exposed to scans as high as 31 volts.It is important to assess the design of commercial support equipment and consid
3、er what a failure of an internal part might do to the flight hardware. Description of Driving Event: (Relevant Historical Lesson(s) Learned)A commercial data scanner using a bank of reed relays failed during thermal-vacuum testing of the SEASAT-A Synthetic Aperture Radar (SAR) Transmitter subassembl
4、y. Transmitter circuits requiring +5 volts were exposed to as high as 31 volts during each scan, resulting in catastrophic failure in the +5 volt circuits of the Transmitter. This problem caused about a two-week slip in the overall schedule, including the loss of 3 days of a one-week thermal-vacuum
5、test and three days to repair the Transmitter.The nature of this problem could have caused the failure to occur anytime the sensor was operated with the ground support equipment as it was configured. The Transmitter GSE was configured with 15 separate regulated power supplies of various voltages. To
6、 allow automatic data acquisition of power supply voltage and current readings during the test, a data scanner driven by a computing calculator was implemented. This scanner consists of a bank of reed relays sequentially addressed by the calculator to acquire each power supply terminal voltage. Each
7、 power supply terminal was connected to a scanner reed relay switch terminal. The other side of the switches were then tied Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-together to the bus, similar to a multiplexer arrangement. In the thermal-vacu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS04351996LESSONSLEARNEDGROUNDSUPPORTEQUIPMENTFAILURECAUSEDDAMAGETOSEASATA1978PDF

链接地址:http://www.mydoc123.com/p-1018082.html