1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA RV 1-2016Application and Installation Guidelines for Armored Cable and Metal-Clad CableNEMA Standards Publication RV 1-2016 Application and Installation Guidelines for Armored Cable and Metal-Clad Cable Published by: Nationa
2、l Electrical Manufacturers Association 1300 North 17th Street, Suite 900 Rosslyn, VA 22209 www.nema.org 2016 National Electrical Manufacturers Association. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protecti
3、on of Literary and Artistic Works, and the International and Pan American copyright conventions. The NEC excerpts shown herein are reprinted with permission from NFPA 70-2017, National Electrical Code, 2016, National Fire Protection Association, Quincy, MA. This reprinted material is not the complet
4、e and official position of the NFPA on the referenced subject, which is represented only by the standard in its entirety. 2016 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by a consensus among persons engaged
5、 in its development at the time it was approved. Consensus does not necessarily mean there was unanimous agreement among every person participating in the development process. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document herein
6、is one, are developed through a voluntary standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. Although NEMA administers the process and establishes rules to promote fairness in the
7、 development of consensus, it does not write the documents, nor does it independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, p
8、roperty, or other damages of any nature, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or co
9、mpleteness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any particular purpose(s) or need(s). NEMA does not undertake to guarantee the performance of any individual manufacturers or sellers products or services by virtue
10、of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document
11、 should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstance. Information and other standards on the topic covered by this publication may be available from other sources,
12、which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety
13、or health purposes. Any certification or other statement of compliance with any health- or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. NEMA RV 1-2016 Page i 2016 National Electrical Manufac
14、turers Association FOREWORD These application and installation guidelines offer practical information on correct application and industry-recommended practices for the installation of armored cable (Type AC) and metal-clad cable (Type MC) in accordance with the National Electrical Code(NEC). These g
15、uidelines were developed by the NEMA Building Wire and Cable section, which has committed to periodically reviewing them for any revisions necessary to address changing conditions, product listing and installation requirements, and technical progress. Comments for proposed revisions are welcomed and
16、 should be submitted to: Senior Technical Director, Operations National Electrical Manufacturers Association 1300 N. 17thStreet, Suite 900 Rosslyn, VA 22209 At the time of approval, the NEMA Building Wire and Cable Group had the following members: AFC Cable Systems, Inc., a part of Atkore Internatio
17、nal New Bedford, MA Anamet Electrical, Inc. Mattoon, IL Cerro Wire LLC Hartselle, AL Colonial Wire they only provide guidance on where and how the cable may be used. The following provides additional guidance on the uses of Type AC cable: General A key provision of the permitted uses of Type AC is t
18、hat Type AC cable is required to comply with all applicable sections of the NEC. While 320.10 permits Type AC to be used as branch circuits and feeders, other NEC articles that apply to the particular installation must be reviewed to determine if additional requirements or restrictions apply. For ex
19、ample, 517.13(A) permits Type AC cable for use in patient care areas of healthcare facilities. However, in accordance with 517.13(B), the cable must contain an insulated equipment grounding conductor. Where Not Subject to Physical Damage Type AC cable must be protected from physical damage. This inc
20、ludes installing the cable at heights and locations where the cable will not be exposed to damage. It also includes providing mechanical protection for the cable from nails and screws in accordance with 300.4(D) by maintaining a 1-1/4 in. (32 mm) distance from the edge of a framing member, or by pro
21、viding a metal plate where the distance cannot be maintained from the edge of a framing member or a furring strip. In Both Exposed and Concealed Installations Type AC cable is permitted for installation in both exposed and concealed work; however, the cable must be protected from physical damage. Ex
22、posed work includes installations above suspended ceilings where installed behind panels designed to allow access. Where installed above suspended ceilings, 300.11 should be consulted for requirements for securing and supporting the cable. In Cable Tray All UL Listed Type AC cable is acceptable for
23、use in cable tray. There is no marking on the cable that indicates that the cable is identified for such use because the metallic armor enables the cable to meet the flame requirements for cable installed in cable tray. If documentation is required to show that Type AC is identified for use in cable
24、 tray, ULs Guide Information for Electrical Equipment (White Book) contains the necessary information. NEC Article 392 should be consulted for cable tray installation requirements. In Dry Locations Type AC cable is rated only for dry locations. The insulation used is not suitable for wet locations.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMARV12016APPLICATIONANDINSTALLATIONGUIDELINESFORARMOREDCABLEANDMETALCLADCABLEPDF

链接地址:http://www.mydoc123.com/p-994397.html