NEMA PREMIUM-2014 General Specification for Consultants Industrial and Municipal NEMA Premium Efficiency Electric Motors.pdf
《NEMA PREMIUM-2014 General Specification for Consultants Industrial and Municipal NEMA Premium Efficiency Electric Motors.pdf》由会员分享,可在线阅读,更多相关《NEMA PREMIUM-2014 General Specification for Consultants Industrial and Municipal NEMA Premium Efficiency Electric Motors.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA PREMIUMGeneral Specification forConsultants, Industrialand Municipal: NEMAPremium EfficiencyElectric Motors General Specification for Consultants, Industrial and Municipal: NEMA Premium Efficiency Electric Motors 2014 Nation
2、al Electrical Manufacturers Association 2014 National Electrical Manufacturers Association General Specification for Consultants, Industrial and Municipal: NEMA PremiumEfficiency Electric Motors Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite 900 Rosslyn, Vi
3、rginia 22209 www.nema.org 2014 National Electrical Manufacturers Association. All rights, including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pan American copy
4、right conventions. NEMA Premium 2014 Page ii 2014 National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by a consensus among persons engaged in its development at the time it was approved. Consensus does not necessari
5、ly mean there was unanimous agreement among every person participating in the development process. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document herein is one, are developed through a voluntary standards development process. This
6、 process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. Although NEMA administers the process and establishes rules to promote fairness in the development of consensus, it does not write the documents, nor does it indep
7、endently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, or other damages of any nature, whether special, indirect, consequen
8、tial, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or completeness of any information published herein, and disclaims and makes no wa
9、rranty that the information in this document will fulfill any particular purpose(s) or need(s). NEMA does not undertake to guarantee the performance of any individual manufacturers or sellers products or services by virtue of this standard or guide. In publishing and making this document available,
10、NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this document should rely on his or her own independent judgment or, as appropriate, seek
11、the advice of a competent professional in determining the exercise of reasonable care in any given circumstance. Information and other standards on the topic covered by this publication may be available from other sources, which the user may wish to consult for additional views or information not co
12、vered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for safety or health purposes. Any certification or other statement of compliance with a
13、ny health- or safety-related information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. NEMA Premium 2014 Page iii 2014 National Electrical Manufacturers Association TABLE OF CONTENTS Page Foreword.iv 1 GENERAL.1 2 DESI
14、GN STANDARDS.1 3 SERVICE CONDITIONS.1 3.1 Usual Service Conditions1 4 ENCLOSURES.1 5 ELECTRICAL DESIGN1 6 MECHANICAL DESIGN.2 6.1 Bearings. 2 6.2 Lubrication2 6.3 Other2 6.4 Accessories (When Specified).2 7 SUBMITTAL DATA REQUIRED.2 8 TESTS (IN ADDITION TO MANUFACTURERS STANDARD TESTS) .2 ANNEXES An
15、nex A NEMA MG 1-2014 Table 12-12, Full-Load Efficiencies for 60 Hz Premium Efficiency Medium Electric Motors Rated 600 Volts or Less (Random Wound) .3 Annex B NEMA MG 1-2014 Table 12-13, Full-Load Efficiencies for 60 Hz Premium Efficiency Medium Electric Motors Rated 5000 Volts or Less (Form Wound).
16、5 Annex C NEMA MG1-2014 Table 20-B Full-Load Efficiencies For 60 Hz Premium Efficiency Large Electric Motors Rated 600 Volts Or Less (Random Wound) .6 Annex D NEMA MG1-2014 Table 20-C Full-Load Efficiencies For 60 Hz Premium Efficiency Large Electric Motors Rated 5000 Volts Or Less (Form Wound) 7 NE
17、MA Premium 2014 Page iv 2014 National Electrical Manufacturers Association Foreword In the preparation of this publication, input of users and other interested parties has been sought and evaluated. Inquiries, comments, and proposed or recommended revisions should be submitted to the concerned NEMA
18、product Subdivision by contacting the following: Senior Technical Director, Operations National Electrical Manufacturers Association 1300 North 17th Street, Suite 900 Rosslyn, VA 22209 This publication was developed by the Motors and Generators Section. Section approval of the document does not nece
19、ssarily imply that all section members voted for its approval or participated in its development. At the time it was approved, the Section was composed of the following members: Baldor Electric Company Fort Smith, AR Brook Crompton North America Toronto, Canada Cummins, Incorporated Minneapolis, MN
20、Nidec Motor Corporation St. Louis, MO GE Industrial Systems Fort Wayne, IN Howell Electric Motors Plainfield, NJ Peerless-Winsmith, Incorporated Warren, OH Regal-Beloit Corporation Beloit, WI SEW-Eurodrive, Incorporated Lyman, SC Siemens Industry Incorporated Norwood, OH Sterling Electric, Incorpora
21、ted Irvine, CA TECO-Westinghouse Motor Company Round Rock, TX The Imperial Electric Company Akron, OH Toshiba International Corporation Houston, TX WEG Electric Corp Duluth, GA NEMA Premium 2014 Page 1 2014 National Electrical Manufacturers Association 1 GENERAL The intent of this specification is t
22、o outline the minimum requirements for three-phase ac induction motors applied to municipal and industrial applications for operation on voltages 5000 volts or less, rated 2500HP or less, operating more than 2000 hours per year at 75% of full-load. 2 DESIGN STANDARDS In addition to this specificatio
23、n, equipment shall comply with the current applicable standards promulgated by the following organizations: AFBMA Anti-Friction Bearing Manufacturers Association ANSI American National Standards Institute ASTM American Society of Testing Materials AWWA American Water Works Association IEEE Institute
24、 of Electrical and Electronics Engineers (Testing) HI Hydraulic Institute NEMA National Electrical Manufacturers Association NEMA MG 1 3 SERVICE CONDITIONS 3.1 Usual Service Conditions a) Ambient temperature not greater than 40C and not less than -15C. b) Voltage variation within +/- 10%. c) Frequen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMAPREMIUM2014GENERALSPECIFICATIONFORCONSULTANTSINDUSTRIALANDMUNICIPALNEMAPREMIUMEFFICIENCYELECTRICMOTORSPDF

链接地址:http://www.mydoc123.com/p-994385.html