NEMA PB 2-2011 Deadfront Distribution Switchboards《不露带电部分的配电开关板》.pdf
《NEMA PB 2-2011 Deadfront Distribution Switchboards《不露带电部分的配电开关板》.pdf》由会员分享,可在线阅读,更多相关《NEMA PB 2-2011 Deadfront Distribution Switchboards《不露带电部分的配电开关板》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、NEMA Standards PublicationNational Electrical Manufacturers AssociationNEMA PB 2-2011Deadfront Distribution SwitchboardsNEMA Standards Publication PB 2-2011 Deadfront Distribution Switchboards Published by: National Electrical Manufacturers Association 1300 North 17th Street, Suite 1752 Rosslyn, Vir
2、ginia 22209 www.nema.org Copyright 2011 by the National Electrical Manufacturers Association. All rights including translation into other languages, reserved under the Universal Copyright Convention, the Berne Convention for the Protection of Literary and Artistic Works, and the International and Pa
3、n American Copyright Conventions. Copyright 2011 by the National Electrical Manufacturers Association NOTICE AND DISCLAIMER The information in this publication was considered technically sound by the consensus of persons engaged in the development and approval of the document at the time it was deve
4、loped. Consensus does not necessarily mean that there is unanimous agreement among every person participating in the development of this document. The National Electrical Manufacturers Association (NEMA) standards and guideline publications, of which the document contained herein is one, are develop
5、ed through a voluntary consensus standards development process. This process brings together volunteers and/or seeks out the views of persons who have an interest in the topic covered by this publication. While NEMA administers the process and establishes rules to promote fairness in the development
6、 of consensus, it does not write the document and it does not independently test, evaluate, or verify the accuracy or completeness of any information or the soundness of any judgments contained in its standards and guideline publications. NEMA disclaims liability for any personal injury, property, o
7、r other damages of any nature whatsoever, whether special, indirect, consequential, or compensatory, directly or indirectly resulting from the publication, use of, application, or reliance on this document. NEMA disclaims and makes no guaranty or warranty, express or implied, as to the accuracy or c
8、ompleteness of any information published herein, and disclaims and makes no warranty that the information in this document will fulfill any of your particular purposes or needs. NEMA does not undertake to guarantee the performance of any individual manufacturer or seller s products or services by vi
9、rtue of this standard or guide. In publishing and making this document available, NEMA is not undertaking to render professional or other services for or on behalf of any person or entity, nor is NEMA undertaking to perform any duty owed by any person or entity to someone else. Anyone using this doc
10、ument should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances. Information and other standards on the topic covered by this publication may be available from other sou
11、rces, which the user may wish to consult for additional views or information not covered by this publication. NEMA has no power, nor does it undertake to police or enforce compliance with the contents of this document. NEMA does not certify, test, or inspect products, designs, or installations for s
12、afety or health purposes. Any certification or other statement of compliance with any health or safetyrelated information in this document shall not be attributable to NEMA and is solely the responsibility of the certifier or maker of the statement. PB 2- 2011 Page i Copyright 2011 by the National E
13、lectrical Manufacturers Association CONTENTS Page Foreword iii Section 1 GENERAL 1.1 Scope . 1 1.2 Referenced Standards . 1 1.3 Definitions 3 Section 2 CLASSIFICATIONS, CHARACTERISTICS, AND RATINGS 2.1 General Standards . 11 2.1.1 Arrangement . 11 2.1.2 Equipment Specification . 11 2.1.3 Usual Servi
14、ce Conditions 12 2.1.4 Unusual Service Conditions 13 2.1.5 Temperature Limits . 13 2.2 Rating Standards . 13 2.2.1 General . 13 2.2.2 Voltage Rating 13 2.2.3 Frequency Rating 13 2.2.4 Continuous Current Rating . 13 2.2.5 Insulation Level Rating . 14 2.2.6 Basis of Short-Circuit Current Rating of Swi
15、tchboards . 14 2.2.7 Short-Circuit Current Ratings of Switchboard Devices . 14 Section 3 PRODUCT MARKING 3.1 Required Information . 16 3.2 Location of Markings 16 3.3 Nationally Recognized Standards or Applicable Laws or Regulations 16 Section 4 INSTALLATION, MAINTENANCE, AND STORAGE . 18 Section 5
16、CONSTRUCTION 5.1 General 19 5.2 Type of Enclosure 19 5.2.1 Type 1 . 19 5.2.2 Type 2 . 19 5.2.3 Type 3R 19 5.2.4 Type 5 . 19 5.3 Height of Indoor Enclosures 19 5.4 Phase or Polarity Arrangements 19 5.5 Grounding and Bonding . 20 5.6 Utility Transformer Compartment . 20 Section 6 TEST STANDARDS 6.1 Cl
17、assification of Tests 22 6.1.1 Design Tests (Type Test) . 22 6.1.2 Production Tests (Routine Test) . 23 PB 2-2011 Page ii Copyright 2011 by the National Electrical Manufacturers Association Section 7 APPLICATION STANDARDS 7.1 Selection of Apparatus . 25 7.2 Voltage Ratings 25 7.3 Continuous Current-
18、Carrying Ratings . 25 7.4 Determination of Section Bus and Through Bus Ampacity in a Multisection Switchboard . 25 7.4.1 Calculation of Section Bus Ampacity 25 7.4.2 Calculation of Through Bus Ampacity 27 7.5 Frequency Rating . 27 7.6 Short-Circuit Current Rating 27 7.6.1 Application on System 27 7.
19、6.2 Current-Limiting Devices 27 7.6.3 Calculation 27 7.6.4 Examples for ApplicationDetermination of Switchboard Short-Circuit Current Rating (See Figure 7-1) . 28 7.7 Location, Installation, Operation, and Maintenance 29 7.8 Ground-Fault Protection 30 7.9 Corner-Grounded (Grounded B Phase) Three-Pha
20、se Delta Applications 30 LIST OF FIGURES Figure 1-1 SERVICE EQUIPMENT-SYSTEM GROUND CONNECTED TO NEUTRAL TYPICAL DEADFRONT SWITCHBOARD LAYOUT 8 Figure 1-2 SERVICE EQUIPMENT-SYSTEM GROUND CONNECTED TO GROUND BUS TYPICAL DEADFRONT SWITCHBOARD LAYOUT . 9 Figure 1-3 NON-SERVICE TYPICAL DEADFRONT SWITCHB
21、OARD LAYOUT EQUIPMENT . 10 Figure 3-1 PRODUCT SAFETY LABEL 17 Figure 5-1 UTILITY CURRENT TRANSFORMER COMPARTMENTS 21 Figure 7-1 SWITCHBOARD DIAGRAM . 29 LIST OF TABLES Table 2-1 AMBIENT TEMPERATURE RANGES OF DEVICES COMMONLY MOUNTED IN SWITCHBOARDS . 12 Table 2-2 COMMON VOLTAGE RATINGS OF SWITCHBOAR
22、DS 15 Table 7-1 MINIMUM AMPACITY OF SECTION BUS 26 Table 7-2 MULTIPLYING FACTOR FOR BUS AMPACITIES . 26 PB 2- 2011 Page iii Copyright 2011 by the National Electrical Manufacturers Association Foreword This Standards Publication is intended to provide a basis of common understanding within the electr
23、ical community by aiding the user and specifier in selection and specification of deadfront distribution switchboards for specific applications by stating: a. The general standards for deadfront switchboards including the types, insulating requirements, unusual service conditions, service equipment
24、requirements, ampacity, and markings b. Standard switchboard ratings including short circuit current ratings c. Test procedures and tests for switchboard design and production d. Manufacturing standards for switchboards e. Switchboard application standards to provide proper selection of a switchboar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NEMAPB22011DEADFRONTDISTRIBUTIONSWITCHBOARDS 带电 部分 配电 开关 PDF

链接地址:http://www.mydoc123.com/p-994381.html