NAVY UFGS-23 81 00 00 20-2009 UNITARY AIR CONDITIONING EQUIPMENT《单一空气调节设备》.pdf
《NAVY UFGS-23 81 00 00 20-2009 UNITARY AIR CONDITIONING EQUIPMENT《单一空气调节设备》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-23 81 00 00 20-2009 UNITARY AIR CONDITIONING EQUIPMENT《单一空气调节设备》.pdf(33页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-23 81 00.00 20 (November 2009)-Preparing Activity: NAVFAC SupersedingUFGS-23 81 00.00 20 (July 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2009*SECTION TABLE OF CONTENTSDIVISION 23 - HEATING, VENTILATING, AND AI
2、R CONDITIONINGSECTION 23 81 00.00 20UNITARY AIR CONDITIONING EQUIPMENT11/09PART 1 GENERAL1.1 REFERENCES1.2 RELATED REQUIREMENTS1.3 SUBMITTALS1.4 QUALITY ASSURANCE1.4.1 Modification of References1.4.2 Detail Drawing1.4.3 Safety1.4.4 Posted Operating Instructions1.4.5 Sizing1.5 REFRIGERANTS1.6 ENVIRON
3、MENTAL REQUIREMENTS1.7 SUSTAINABLE DESIGN REQUIREMENTS1.7.1 Local/Regional Materials1.7.2 Environmental DataPART 2 PRODUCTS2.1 ROOM AIR CONDITIONERS2.1.1 Units for Operation on 115 Volts2.1.2 Units for Operation on 208 or 230 Volts2.1.3 Controls2.2 PACKAGED TERMINAL UNITS2.2.1 Heat Pumps2.2.2 Air Co
4、nditioners2.2.3 Indoor Noise Rating2.2.4 Room Cabinets2.2.5 Grilles2.2.6 Wall Sleeves and Mounts2.2.7 Heating Section for Air Conditioners2.2.8 Refrigeration Sections2.2.9 Ventilation Damper Assembly2.2.10 Air Filters2.2.11 ControlsSECTION 23 81 00.00 20 Page 1Provided by IHSNot for ResaleNo reprodu
5、ction or networking permitted without license from IHS-,-,-2.3 HEAT PUMPS, AIR TO AIR2.3.1 Energy Performance2.3.2 Air Coils2.3.3 Supplemental Electric Heaters2.3.4 Compressors2.3.5 Mounting Provisions2.3.6 Temperature Controls2.3.7 Accessories2.4 AIR CONDITIONERS2.4.1 Single Package Type2.4.2 Split
6、-System Type2.4.3 Single Zone Units2.4.4 Multizone Units2.4.5 Heaters2.4.6 Compressors2.4.7 Coils2.4.8 Condenser Controls2.4.9 Fans2.4.10 Filters2.4.11 Filter Boxes2.4.12 Mixing Boxes2.4.13 Thermostats2.4.13.1 Cooling2.4.13.2 Heating2.4.13.3 Supply Air Fan2.5 FILTERS2.5.1 Replaceable Type Filters2.5
7、.2 High Efficiency Filters2.5.3 Cleanable Type Filters2.5.4 Manometers2.6 COATINGS FOR FINNED TUBE COILS2.6.1 Phenolic Coating2.6.2 Chemical Conversion Coating with Polyelastomer Finish Coat2.6.3 Vinyl Coating2.7 MOTORS AND STARTERS2.8 REFRIGERANT PIPING AND ACCESSORIES2.8.1 Factory Charged Tubing2.
8、8.2 Field-Assembled Refrigerant Piping2.8.3 Fittings2.8.4 Brazing Filler Material2.8.5 Pipe Hangers and Supports2.8.6 Pipe Sleeves2.8.6.1 Sleeves in Masonry and Concrete Walls, Floors, and Roofs2.8.6.2 Sleeves in Partitions and Non-Masonry Structures2.9 FINISHES2.10 SOURCE QUALITY CONTROL2.10.1 Salt
9、-Spray TestsPART 3 EXECUTION3.1 EQUIPMENT INSTALLATION3.1.1 Packaged Terminal Air Conditioners and Heat Pumps3.1.2 Unitary Air Conditioning System3.1.3 Room Air Conditioners3.2 PIPING3.2.1 Pipe Hangers and Supports3.2.2 Refrigerant Piping3.2.3 Returning Oil From Refrigerant System3.2.4 Refrigerant D
10、riers, Sight Glass Indicators, and StrainersSECTION 23 81 00.00 20 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.2.5 Strainer Locations and Installation3.2.6 Solenoid Valve Installation3.3 AUXILIARY DRAIN PANS, DRAIN CONNECTIONS, AND DRAIN
11、LINES3.4 ACCESS PANELS3.5 AIR FILTERS3.6 FLASHING AND PITCH POCKETS3.7 IDENTIFICATION TAGS AND PLATES3.8 FIELD QUALITY CONTROL3.8.1 Leak Testing3.8.2 Evacuation, Dehydration, and Charging3.8.3 Start-Up and Initial Operational Tests3.8.4 Performance Tests3.9 WASTE MANAGEMENT3.10 SCHEDULE- End of Sect
12、ion Table of Contents -SECTION 23 81 00.00 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-23 81 00.00 20 (November 2009)-Preparing Activity: NAVFAC SupersedingUFGS-23 81 00.00 20 (July 2006)UNIFIED FACIL
13、ITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated October 2009*SECTION 23 81 00.00 20UNITARY AIR CONDITIONING EQUIPMENT11/09*NOTE: This guide specification covers the requirements for room air conditioners, packaged terminal units, heat pumps, and air conditioners of the single p
14、ackage or split system type.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective project, whether or not
15、brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a
16、UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organiz
17、ation, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the SECTION 23 81 00.00 20 Page 4Provided by IHSNot for ResaleNo reproduction or
18、networking permitted without license from IHS-,-,-Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The
19、 publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AIR-CONDITIONING, HEATING AND REFRIGERATION INSTITUTE (AHRI)AHRI 210/240 (2008) Performance Rating of Unitary Air-Conditioning and Air
20、-Source Heat Pump EquipmentAHRI 310/380 (2004) Standard for Packaged Terminal Air-Conditioners and Heat PumpsAHRI 340/360 (2004) Performance Rating of Commercial and Industrial Unitary Air-Conditioning and Heat Pump EquipmentAHRI 350 (2000) Sound Rating of Non-Ducted Indoor Air-Conditioning Equipmen
21、tAHRI DCAACP (Online) Directory of Certified Applied Air-Conditioning ProductsAHRI DCUP (Online) Directory of Certified Unitary ProductsAMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ASHRAE 15 Std 15 Errata 2007, 2009, Std 34 Errata 2007, 2008, Addenda a-y, aa-ae)
22、ANSI/ASHRAE Standard 15-Safety Standard for Refrigeration Systems and ANSI/ASHRAE Standard 34-Designation and Safety Classification of RefrigerantsASHRAE 52.2 (2007; Addenda B 2008; Errata 2009) Method of Testing General Ventilation Air-Cleaning Devices for Removal Efficiency by Particle SizeASHRAE
23、55 (2004; Int 1:2005; Errata:2006; Int 2:2007; Errata:2007; Addendas A, B:2008; Addendas D - G:2009) Thermal Environmental Conditions for Human OccupancyASHRAE 62.1 (2007; INT 2007; INT 2-15 2008; Errata 2008; Addenda a, b, e, f and h 2008) Ventilation for Acceptable Indoor Air QualitySECTION 23 81
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS23810000202009UNITARYAIRCONDITIONINGEQUIPMENT 单一 空气调节 设备 PDF

链接地址:http://www.mydoc123.com/p-984813.html