NAVY UFGS-13282N 08 01 03-2003 LEAD IN CONSTRUCTION [Replaced By NAVY UFGS-02 83 13 00 20]《建筑中的铅[被NAVY UFGS-02 83 13 00 20代替]》.pdf
《NAVY UFGS-13282N 08 01 03-2003 LEAD IN CONSTRUCTION [Replaced By NAVY UFGS-02 83 13 00 20]《建筑中的铅[被NAVY UFGS-02 83 13 00 20代替]》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-13282N 08 01 03-2003 LEAD IN CONSTRUCTION [Replaced By NAVY UFGS-02 83 13 00 20]《建筑中的铅[被NAVY UFGS-02 83 13 00 20代替]》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA UFGS-13282N (August 2003)-Preparing Activity: NAVFAC SupersedingUFGS-13282N (February 2002)UNIFIED FACILITIES GUIDE SPECIFICATIONSRevised throughout - change not indicated by CHG tags*SECTION TABLE OF CONTENTSDIVISION 13 - SPECIAL CONSTRUCTIONSECTION 13282NLEAD IN CONSTRUCTI
2、ON08/03PART 1 GENERAL1.1 REFERENCES1.2 DEFINITIONS1.2.1 Action Level1.2.2 Area Sampling1.2.3 Competent Person (CP)1.2.4 Contaminated Room1.2.5 Decontamination Shower Facility1.2.6 High Efficiency Particulate Arrestor (HEPA) Filter Equipment1.2.7 Lead1.2.8 Lead Control Area1.2.9 Lead Permissible Expo
3、sure Limit (PEL)1.2.10 Material Containing Lead/Paint with Lead (MCL/PWL)1.2.11 Personal Sampling1.2.12 Physical Boundary1.3 DESCRIPTION1.3.1 Description of Work1.3.2 Coordination with Other Work1.4 SUBMITTALS1.5 QUALITY ASSURANCE1.5.1 Qualifications1.5.1.1 Competent Person (CP)1.5.1.2 Training Cert
4、ification1.5.1.3 Testing Laboratory1.5.1.4 Third Party Consultant Qualifications1.5.2 Requirements1.5.2.1 Competent Person (CP) Responsibilities1.5.2.2 Lead Compliance Plan1.5.2.3 Occupational and Environmental Assessment Data ReportSECTION 13282N Page 1Provided by IHSNot for ResaleNo reproduction o
5、r networking permitted without license from IHS-,-,-1.5.2.4 Medical Examinations1.5.2.5 Training1.5.2.6 Respiratory Protection Program1.5.2.7 Hazard Communication Program1.5.2.8 Lead Waste Management1.5.2.9 Environmental, Safety and Health Compliance1.5.3 Pre-Construction Conference1.6 EQUIPMENT1.6.
6、1 Respirators1.6.2 Special Protective Clothing1.6.3 Rental Equipment Notification1.6.4 Vacuum Filters1.6.5 Equipment for Government Personnel1.7 PROJECT/SITE CONDITIONS1.7.1 Protection of Existing Work to RemainPART 2 PRODUCTSPART 3 EXECUTION3.1 PREPARATION3.1.1 Protection3.1.1.1 Notification3.1.1.2
7、 Lead Control Area3.1.1.3 Furnishings3.1.1.4 Heating, Ventilating and Air Conditioning (HVAC) Systems3.1.1.5 Decontamination Shower Facility3.1.1.6 Eye Wash Station3.1.1.7 Mechanical Ventilation System3.1.1.8 Personnel Protection3.2 ERECTION3.2.1 Lead Control Area Requirements3.3 APPLICATION3.3.1 Le
8、ad Work3.3.2 Paint with Lead or Material Containing Lead Removal3.3.2.1 Paint with Lead or Material Containing Lead - Indoor Removal3.3.2.2 Paint with Lead or Material Containing Lead - Outdoor Removal3.3.3 Personnel Exiting Procedures3.4 FIELD QUALITY CONTROL3.4.1 Tests3.4.1.1 Air and Wipe Sampling
9、3.4.1.2 Sampling After Removal3.4.1.3 Testing of Material Containing Lead Residue3.5 CLEANING AND DISPOSAL3.5.1 Cleanup3.5.1.1 Clearance Certification3.5.2 Disposal3.5.2.1 Disposal Documentation3.5.2.2 Payment for Hazardous Waste- End of Section Table of Contents -SECTION 13282N Page 2Provided by IH
10、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA UFGS-13282N (August 2003)-Preparing Activity: NAVFAC SupersedingUFGS-13282N (February 2002)UNIFIED FACILITIES GUIDE SPECIFICATIONSRevised throughout - change not indicated by CHG tags*SECTION
11、 13282NLEAD IN CONSTRUCTION08/03*NOTE: This guide specification covers the requirements for protection of workers, disposal of lead painted material and provides guidelines/recommendations for cleanup of lead on construction projects impacting material containing lead and/or lead based paint. This g
12、uide specification does not apply to abatement of lead hazards in target housing or child occupied facilities. Guide Specification 13283, Removal and Disposal of Paint with Lead is to be used for abatement or control of lead hazards in 40 CFR 745 defined child occupied facilities or target housing.C
13、omments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitt
14、ed as a Criteria Change Request (CCR).Use of electronic communication is encouraged.Brackets are used in the text to indicate designer choices or locations where text must be supplied by the designer.*NOTE: Obtain project specific information and appropriate sampling of Paint with Lead (PWL) or Mate
15、rial Containing Lead (MCL) that will be removed or disturbed.SECTION 13282N Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*NOTE: When historic preservation work will disturb PWL, refer to the Secretary of the Interiors Standards for the Treat
16、ment of Historic Properties and/or Brief 37, “Appropriate Methods for Reducing Lead-Paint Hazards in Historic Housing“ as appropriate. *NOTE: Projects involving housing improvement, maintenance, or repair are not considered a lead-based paint hazard abatement action even if the effect of the work re
17、moves (or reduces) lead exposure potentials to the occupants. However, appropriate precautions for protecting occupants and leaving the housing clean (clearance) after concluding any work disturbing lead must be considered. Specific training and certification requirements (40 CFR 745 or authorized s
18、tate program requirements) may not be necessary for all projects. However, it is strongly recommended that the specification editor have appropriate training regarding lead. *PART 1 GENERAL1.1 REFERENCESThe publications listed below form a part of this specification to the extent referenced. The pub
19、lications are referred to within the text by the basic designation only.AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)ANSI Z88.2 (1992) Respiratory ProtectionU.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)29 CFR 1926.103 Respiratory Protection29 CFR 1926.21 Safety Training and Education29 CFR
20、 1926.33 Access to Employee Exposure and Medical Records29 CFR 1926.55 Gases, Vapors, Fumes, Dusts, and Mists29 CFR 1926.59 Hazard Communication29 CFR 1926.62 LeadSECTION 13282N Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-29 CFR 1926.65 Haz
21、ardous Waste Operations and Emergency Response40 CFR 260 Hazardous Waste Management System: General40 CFR 261 Identification and Listing of Hazardous Waste40 CFR 262 Generators of Hazardous Waste40 CFR 263 Transporters of Hazardous Waste40 CFR 264 Standards for Owners and Operators of Hazardous Wast
22、e Treatment, Storage and Disposal Facilities40 CFR 265 Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage and Disposal Facilities40 CFR 268 Land Disposal Restrictions40 CFR 745 Lead-Based Paint Poisoning Prevention in Certain Residential Structures49 CFR 172 Haza
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便