NAVY UFGS-03 53 14 00 20-2010 LIGHT REFLECTIVE NONFERROUS METALLIC AGGREGATE FLOOR SYSTEM《照明反射不含铁金属的聚合楼面系统》.pdf
《NAVY UFGS-03 53 14 00 20-2010 LIGHT REFLECTIVE NONFERROUS METALLIC AGGREGATE FLOOR SYSTEM《照明反射不含铁金属的聚合楼面系统》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-03 53 14 00 20-2010 LIGHT REFLECTIVE NONFERROUS METALLIC AGGREGATE FLOOR SYSTEM《照明反射不含铁金属的聚合楼面系统》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-03 53 14.00 20 (February 2010)-Preparing Activity: NAVFAC SupersedingUFGS-03 53 14.00 20 (April 2006)UFGS-03010N (August 2003)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION TABLE OF CONTENTSDIVISION 03 - CONC
2、RETESECTION 03 53 14.00 20LIGHT REFLECTIVE NONFERROUS METALLIC AGGREGATE FLOOR SYSTEM02/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.2.1 Sample Installation1.2.2 Material Sample1.2.3 Alternates1.3 DELIVERY AND STORAGE1.4 WARRANTY1.5 QUALITY CONTROLPART 2 PRODUCTS2.1 CONCRETE2.2 NON-FERROUS, NON-OXI
3、DIZING METALLIC AGGREGATE, DRY-SHAKE SURFACE HARDENER2.3 SURFACE EVAPORATION RETARDANT2.4 CURING AND SEALINGPART 3 EXECUTION3.1 CONCRETE PLACEMENT3.1.1 Application of Surface Hardener3.1.2 Field Service3.1.3 Curing and Protection (Water Based Wax Emulsion)3.2 Cleaning and Surface Preparation- End of
4、 Section Table of Contents -SECTION 03 53 14.00 20 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-03 53 14.00 20 (February 2010)-Preparing Activity: NAVFAC SupersedingUFGS-03 53 14.00 20 (April 2006)UFGS-03
5、010N (August 2003)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION 03 53 14.00 20LIGHT REFLECTIVE NONFERROUS METALLIC AGGREGATE FLOOR SYSTEM02/10*NOTE: This guide specification covers the requirements for light reflective, non-oxidizing, dry shake
6、 surface hardener for concrete hangar floor finish.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective p
7、roject, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Re
8、commended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in th
9、is paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the SECTION 03 53 14.00 20 Page 2Provided by IHSNot for Re
10、saleNo reproduction or networking permitted without license from IHS-,-,-Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the pub
11、lish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.ACI INTERNATIONAL (ACI)ACI 305R (1999; Errata 2006) Hot Weather ConcretingACI 308.1 (1998) Standard Specificati
12、on for Curing ConcreteACI 308R (2001; R 2008) Guide to Curing ConcreteASTM INTERNATIONAL (ASTM)ASTM C 1315 (2008) Standard Specification for Liquid Membrane-Forming Compounds Having Special Properties for Curing and Sealing ConcreteASTM C 309 (2007) Standard Specification for Liquid Membrane-Forming
13、 Compounds for Curing ConcreteASTM C 779/C 779M (2005) Abrasion Resistance of Horizontal Concrete SurfacesASTM C 944/C 944M (1999; R 2005e1) Standard Test Method for Abrasion Resistance of Concrete or Mortar Surfaces by the Rotating-Cutter Method1.2 SUBMITTALS*NOTE: Review submittal description (SD)
14、 definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government
15、approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals
16、requiring Government approval on Army projects, a code of up to three characters within SECTION 03 53 14.00 20 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-the submittal tags may be used following the “G“ designation to indicate the approvin
17、g authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Project Office. Codes following
18、 the “G“ typically are not used for Navy, Air Force, and NASA projects.Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects.*Government approval is required for submittals with a “G“ designation; submittals not having a “G“ desi
19、gnation are for Contractor Quality Control approval.for information only. When used, a designation following the “G“ designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:SD-03 Pr
20、oduct DataNon-oxidizing metallic aggregate surface hardener GSD-04 SamplesSample installationMaterial sampleSD-07 CertificatesStatement of alternates G1.2.1 Sample InstallationA minimum of 100 square feet of the hangar _ floor slab shall be finished in a location as directed by the Contracting Offic
21、er. Color, texture and installation procedures are of prime importance. After approval by the Contracting Officer, the Contractor shall maintain the same controls and procedures throughout the installation process. Before acceptance, all work will be compared to the sample area.1.2.2 Material Sample
22、Samples of materials, color, and finish type shall be submitted to the Contracting Officer for approval.1.2.3 AlternatesSubmittals for an alternate product shall contain the following from an independent laboratory. Unit weight, abrasion resistance test in accordance with ASTM C 944/C 944M and ASTM
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS03531400202010LIGHTREFLECTIVENONFERROUSMETALLICAGGREGATEFLOORSYSTEM 照明 反射 不含铁 金属 聚合 楼面 系统 PDF

链接地址:http://www.mydoc123.com/p-984707.html