NAVY UFGS-03 52 16 19-2011 LIGHTWEIGHT INSULATING CONCRETE OVERLAY《轻质隔热混凝土覆盖物》.pdf
《NAVY UFGS-03 52 16 19-2011 LIGHTWEIGHT INSULATING CONCRETE OVERLAY《轻质隔热混凝土覆盖物》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-03 52 16 19-2011 LIGHTWEIGHT INSULATING CONCRETE OVERLAY《轻质隔热混凝土覆盖物》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-03 52 16.19 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-03 52 16.19 (August 2008)UFGS-03 52 16.19 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 03 - CONCRETE
2、SECTION 03 52 16.19LIGHTWEIGHT INSULATING CONCRETE OVERLAY08/11PART 1 GENERAL1.1 REFERENCES1.2 QUALIFICATIONS OF APPLICATOR1.3 SUBMITTALS1.4 DELIVERY AND STORAGE1.5 ENVIRONMENTAL CONDITIONS1.5.1 Normal Conditions1.5.2 Cold Weather Conditions1.6 SAFETY AND HEALTH REQUIREMENTS1.7 QUALITY ASSURANCE1.7.
3、1 Fabricators Compatibility CertificatesPART 2 PRODUCTS2.1 PORTLAND CEMENT2.2 AGGREGATE2.3 AIR-ENTRAINMENT2.4 FOAMING AGENTS2.5 WATER2.6 EXPANSION JOINT FILLER MATERIAL2.7 WELDED WIRE FABRIC2.8 INSULATION BOARDPART 3 EXECUTION3.1 PERFORMANCE REQUIREMENTS3.1.1 Minimum Compressive Strength3.1.2 Minimu
4、m Oven Dry Density3.1.3 Coefficient of Heat Transmission3.2 SURFACE PREPARATION3.3 STEEL ROOF DECKING3.4 REINFORCING MESH OR WELDED WIRE FABRIC3.5 APPLICATION OF INSULATING CONCRETE AND INSULATION BOARD3.5.1 MixingSECTION 03 52 16.19 Page 1Provided by IHSNot for ResaleNo reproduction or networking p
5、ermitted without license from IHS-,-,-3.5.2 Conveying3.5.3 Expansion Joints3.5.4 Slurry Coat and Insulation Board3.5.5 Insulating Concrete Fill3.5.5.1 Compacting3.5.5.2 Curing3.5.5.3 Patching3.6 FIELD TESTS3.6.1 Test Specimens- End of Section Table of Contents -SECTION 03 52 16.19 Page 2Provided by
6、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-03 52 16.19 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-03 52 16.19 (August 2008)UFGS-03 52 16.19 (April 2006)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are
7、in agreement with UMRL dated July 2011*SECTION 03 52 16.19LIGHTWEIGHT INSULATING CONCRETE OVERLAY08/11*NOTE: This guide specification covers the requirements for insulating concrete roof deck systems with embedded insulation board only.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (
8、UFGS) Format Standard when editing this guide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove
9、 information and requirements not required in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: The following information should be included
10、on the project drawings:1. High points and valleys on roof plan2. Specific slope requirements3. Roof drain details4. Reinforcement locations and details.5. Location of roof projections.6. Moisture venting details and locations for insulating concrete over cast-in-place or precast structural concrete
11、 substrates.SECTION 03 52 16.19 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-7. Location of corrugated steel form decking sections with slots for moisture venting.8. Insulation board thickness.9. Vented flashing details and a mechanical fast
12、ening base sheet for built-up roof.10. Seismic design details. Include diaphragm shear values, steel form deck design, and welding patterns if Section 05 30 00 STEEL DECKS is not in contract.*NOTE: Insulating concrete could be applied over structural or precast concrete, or corrugated steel form dec
13、king. Provide design details to meet minimum roof slope of 1/24.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by org
14、anization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.Refer
15、ences not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to wit
16、hin the text by the basic designation only.AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ASHRAE FUN IP (2009; Errata 2010) Fundamentals Handbook, I-P EditionASHRAE FUN SI (2009; Errata 2010) Fundamentals Handbook, SI EditionSECTION 03 52 16.19 Page 4Provided by IH
17、SNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASTM INTERNATIONAL (ASTM)ASTM A185/A185M (2007) Standard Specification for Steel Welded Wire Reinforcement, Plain, for ConcreteASTM C150/C150M (2011) Standard Specification for Portland CementASTM C332 (2009) Lightwe
18、ight Aggregates for Insulating ConcreteASTM C495 (2007) Compressive Strength of Lightweight Insulating ConcreteASTM C578 (2011) Standard Specification for Rigid, Cellular Polystyrene Thermal InsulationASTM C612 (2010) Mineral Fiber Block and Board Thermal InsulationASTM C796 (2004) Foaming Agents fo
19、r Use in Producing Cellular Concrete Using Preformed Foam1.2 QUALIFICATIONS OF APPLICATORPerform work by or under the supervision of personnel specializing in insulating concrete application and having not less than 2 years experience.1.3 SUBMITTALS*NOTE: Review submittal description (SD) definition
20、s in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS035216192011LIGHTWEIGHTINSULATINGCONCRETEOVERLAY 隔热 混凝土 覆盖 PDF

链接地址:http://www.mydoc123.com/p-984706.html