NAVY UFGS-03 52 00-2011 LIGHTWEIGHT CONCRETE ROOF INSULATION《轻质混凝土屋顶保温》.pdf
《NAVY UFGS-03 52 00-2011 LIGHTWEIGHT CONCRETE ROOF INSULATION《轻质混凝土屋顶保温》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-03 52 00-2011 LIGHTWEIGHT CONCRETE ROOF INSULATION《轻质混凝土屋顶保温》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-03 52 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-03 52 00 (April 2006)UFGS-03520 (August 2004)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 2011*SECTION TABLE OF CONTENTSDIVISION 03 - CONCRETESECTION 03 5
2、2 00LIGHTWEIGHT CONCRETE ROOF INSULATION08/11PART 1 GENERAL1.1 REFERENCES1.2 QUALIFICATIONS OF APPLICATOR1.3 SUBMITTALS1.4 DELIVERY AND STORAGE1.5 ENVIRONMENTAL CONDITIONS1.5.1 Normal Conditions1.5.2 Cold Weather Conditions1.6 SAFETY AND HEALTH REQUIREMENTS1.7 QUALITY ASSURANCE1.7.1 Fabricators Comp
3、atibility CertificatesPART 2 PRODUCTS2.1 PORTLAND CEMENT2.2 AGGREGATE2.3 AIR-ENTRAINMENT2.4 FOAMING AGENTS2.5 WATER2.6 EXPANSION JOINT FILLER MATERIAL2.7 WELDED WIRE FABRIC2.8 INSULATION BOARDPART 3 EXECUTION3.1 PERFORMANCE REQUIREMENTS3.1.1 Minimum Compressive Strength3.1.2 Minimum Oven Dry Density
4、3.1.3 Coefficient of Heat Transmission3.2 SURFACE PREPARATION3.3 STEEL ROOF DECKING3.4 REINFORCING MESH OR WELDED WIRE FABRIC3.5 APPLICATION OF INSULATING CONCRETE AND INSULATION BOARD3.5.1 MixingSECTION 03 52 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without lice
5、nse from IHS-,-,-3.5.2 Conveying3.5.3 Expansion Joints3.5.4 Slurry Coat and Insulation Board3.5.5 Insulating Concrete Fill3.5.5.1 Compacting3.5.5.2 Curing3.5.5.3 Patching3.6 FIELD TESTS3.6.1 Test Specimens- End of Section Table of Contents -SECTION 03 52 00 Page 2Provided by IHSNot for ResaleNo repr
6、oduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-03 52 00 (August 2011)-Preparing Activity: NAVFAC SupersedingUFGS-03 52 00 (April 2006)UFGS-03520 (August 2004)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated July 20
7、11*SECTION 03 52 00LIGHTWEIGHT CONCRETE ROOF INSULATION08/11*NOTE: This guide specification covers the requirements for insulating concrete roof deck systems with embedded insulation board only.Adhere to UFC 1-300-02 Unified Facilities Guide Specifications (UFGS) Format Standard when editing this gu
8、ide specification or preparing new project specification sections. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required
9、 in respective project, whether or not brackets are present.Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR).*NOTE: The following information should be included on the project drawings:1. High points and
10、 valleys on roof plan2. Specific slope requirements3. Roof drain details4. Reinforcement locations and details.5. Location of roof projections.6. Moisture venting details and locations for insulating concrete over cast-in-place or precast structural concrete substrates.SECTION 03 52 00 Page 3Provide
11、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-7. Location of corrugated steel form decking sections with slots for moisture venting.8. Insulation board thickness.9. Vented flashing details and a mechanical fastening base sheet for built-up roof.10. Seismi
12、c design details. Include diaphragm shear values, steel form deck design, and welding patterns if Section 05 30 00 STEEL DECKS is not in contract.*NOTE: Insulating concrete could be applied over structural or precast concrete, or corrugated steel form decking. Provide design details to meet minimum
13、roof slope of 1/24.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use t
14、he Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically
15、 be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AM
16、ERICAN SOCIETY OF HEATING, REFRIGERATING AND AIR-CONDITIONING ENGINEERS (ASHRAE)ASHRAE FUN IP (2009; Errata 2010) Fundamentals Handbook, I-P EditionASHRAE FUN SI (2009; Errata 2010) Fundamentals Handbook, SI EditionSECTION 03 52 00 Page 4Provided by IHSNot for ResaleNo reproduction or networking per
17、mitted without license from IHS-,-,-ASTM INTERNATIONAL (ASTM)ASTM A185/A185M (2007) Standard Specification for Steel Welded Wire Reinforcement, Plain, for ConcreteASTM C150/C150M (2011) Standard Specification for Portland CementASTM C332 (2009) Lightweight Aggregates for Insulating ConcreteASTM C495
18、 (2007) Compressive Strength of Lightweight Insulating ConcreteASTM C578 (2011) Standard Specification for Rigid, Cellular Polystyrene Thermal InsulationASTM C612 (2010) Mineral Fiber Block and Board Thermal InsulationASTM C796 (2004) Foaming Agents for Use in Producing Cellular Concrete Using Prefo
19、rmed Foam1.2 QUALIFICATIONS OF APPLICATORPerform work by or under the supervision of personnel specializing in insulating concrete application and having not less than 2 years experience.1.3 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and e
20、dit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. On
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0352002011LIGHTWEIGHTCONCRETEROOFINSULATION 混凝土 屋顶 保温 PDF

链接地址:http://www.mydoc123.com/p-984705.html