1、*USACE / NAVFAC / AFCESA / NASA UFGS-008 36 19 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-08370 (August 2001)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated 1 April 2006Latest change indicated by CHG tags*SECTION TABLE OF CONTENTSDIVISION
2、 08 - OPENINGSSECTION 008 36 19VERTICAL LIFT DOORS04/06PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 MATERIALS2.1.1 Steel Sheet2.1.2 Steel Shapes2.1.3 Aluminum Extrusions2.1.4 Aluminum Sheets and Strips2.1.5 Glass2.2 DOORS2.3 MANUAL OPERATORS2.4 ELEC
3、TRIC OPERATORS2.4.1 Motors2.4.2 Controls2.4.3 Safety Device2.4.4 Control Transformers2.4.5 Electrical Components2.4.6 Hazardous Locations2.5 WEATHER SEALS AND SAFETY DEVICE2.6 FINISHES2.6.1 Galvanized and Shop Primed2.6.2 AluminumPART 3 EXECUTION3.1 FABRICATION3.1.1 Door Sections3.1.1.1 Insulated Se
4、ctions3.1.1.2 Aluminum SectionsSECTION 08 36 19 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.1.2 Guides and Jamb Plates3.1.3 Hardware3.1.4 Glazing3.2 INSTALLATION3.3 ELECTRICAL WORK3.4 TESTING- End of Section Table of Contents -SECTION 08
5、36 19 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-008 36 19 (April 2006)-Preparing Activity: NAVFAC Replacing without change UFGS-08370 (August 2001)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are
6、in agreement with UMRL dated 1 April 2006Latest change indicated by CHG tags*SECTION 008 36 19VERTICAL LIFT DOORS04/06*NOTE: This guide specification covers the requirements for vertical lift metal doors of the stacking type.Comments and suggestions on this guide specification are welcome and should
7、 be directed to the technical proponent of the specification. A listing of technical proponents, including their organization designation and telephone number, is on the Internet.Recommended changes to a UFGS should be submitted as a Criteria Change Request (CCR).Use of electronic communication is e
8、ncouraged.Brackets are used in the text to indicate designer choices or locations where text must be supplied by the designer.*NOTE: On the drawings, show:1. Location and size of door openings.2. Type and details of door frames.3. Design wind loads required for the building.4. Wire and conduit from
9、power source to operators and controls for electrically-operated doors.5. Electrical power characteristics and location of motors and control station.6. Counterweight tower location relative to door.*SECTION 08 36 19 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without
10、license from IHS-,-,-PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use
11、the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automaticall
12、y be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.A
13、MERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)AISC 335 (1989) Structural Steel Buildings Allowable Stress Design and Plastic DesignASTM INTERNATIONAL (ASTM)ASTM A 123/A 123M (2002) Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel ProductsASTM A 36/A 36M (2005) Carbon Structural SteelASTM A 653/A
14、 653M (2004a) Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM B 209 (2004) Aluminum and Aluminum-Alloy Sheet and PlateASTM B 209M (2004) Aluminum and Aluminum-Alloy Sheet and Plate (Metric)ASTM B 221 (2005) Aluminum and Aluminum-Alloy Extrude
15、d Bars, Rods, Wire, Profiles, and TubesASTM B 221M (2005) Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes (Metric)SECTION 08 36 19 Page 4Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NATIONAL ASSOCIATION OF ARCHITECTURAL
16、METAL MANUFACTURERS (NAAMM)NAAMM MFM (1988) Metal Finishes ManualNATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)NEMA ICS 1 (2000; R 2005) Industrial Control and Systems: General RequirementsNEMA ICS 2 (1996; R 2004) Standard for Industrial Control and Systems: Controllers, Contractors, and Over
17、load Relays Rated Not More than 2000 Volts AC or 750 Volts DC: Part 8 - Disconnect Devices for Use in Industrial Control EquipmentNEMA ICS 6 (1993; R 2001) Industrial Control and Systems: EnclosuresNEMA MG 1 (2003; R 2004) Motors and GeneratorsNEMA ST 20 (1992; R 1997) Dry-Type Transformers for Gene
18、ral ApplicationsNATIONAL FIRE PROTECTION ASSOCIATION (NFPA)NFPA 70 (2005) National Electrical Code1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittal
19、s should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed throug
20、h the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation
21、 to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineering Division or other organization in the District Office); “AO“ for Area Office; “RO“ for Resident Office; and “PO“ for Projec
22、t Office. Codes following the “G“ typically are not used for Navy, Air Force, and NASA projects.SECTION 08 36 19 Page 5Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Choose the first bracketed item for Navy, Air Force and NASA projects, or choose th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS00836192006VERTICALLIFTDOORS 垂直 升降 PDF

链接地址:http://www.mydoc123.com/p-984680.html