NAVY MIL-V-24761 (1)-1995 VENTILATING SETS PORTABLE DAMAGE CONTROL《便携式应急控制通风设置》.pdf
《NAVY MIL-V-24761 (1)-1995 VENTILATING SETS PORTABLE DAMAGE CONTROL《便携式应急控制通风设置》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-V-24761 (1)-1995 VENTILATING SETS PORTABLE DAMAGE CONTROL《便携式应急控制通风设置》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-V-24761(SH) AMENDMENT 1 29 May 1995 MILITARY SPECIFICATION VENTILATING SETS, PORTABLE DAMAGE CONTROL This amendment forms a part of MIL-V-24761, dated 17 June 1991, and is approved for use by all Departments and Agencies of the Department of Defense. PAGE 13 3.6.3.4.6, delete and substitute: 3.6
2、.3.4.6 Ai Alternating current motors shall not have excessive horsepower, but shall have sufficient torque to start the fans at a motor terminal voltage of 75 volts. The motor shall drive the fan continuously at a motor terminal voltage of 104 volts when the fan is operating at its rated design poin
3、t as specified in 3.6.2.1. Alternating current motors shall conform to MIL-M-17059 as augmented by the following requirements: De s i gn : Voltage : 115 Vac, 60Hz, single phase Service : Navy Service A Horsepower: As required by fan Rated speed: As required by fan Frame : As required by fan Mounting
4、 : Face Duty: Continuous, air over cooling Enclosure: Explosion-proof, group D (See Insulation: Class B or F (see Bearings : Ball (see 3.6.3.4.5) Ambient temperature: 65 degrees Celsius Maximum temperature rise: 55 degrees Celsius Synchronous rated speed: 3600 revolutions per minute (r/min) Thermal
5、protection: UL 547 (see 3.6.3.4.4) Maximum safelocked rotor time: 90 seconds Split phase 3.6.3.4.2) 3.6.3.4.6.2) AMSC N/A FSC 4140 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Page 1 of 3 Provided by IHSNot for ResaleNo reproduction or networking permitted withou
6、t license from IHS-,-,-MIL-V-S4761(SH) AMENDMENT 1 PAGE 14 3.6.3.4.6.2, delete and substitute: 3.6.3.4.6.2 Insulation system. Alternating current motors shall be provided with an insulation system in accordance with MIL-M-17059. 3.6.3.4.7, delete and substitute: 3.6.3.4.7 Direct current motors. Dire
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILV2476111995VENTILATINGSETSPORTABLEDAMAGECONTROL 便携式 应急 控制 通风 设置 PDF

链接地址:http://www.mydoc123.com/p-983089.html