NAVY MIL-T-960 E (3)-1991 TRAPS STEAM INTERMITTENT DISCHARGE AND CONTINUOUS FLOW NAVAL SHIPBOARD《海军舰间歇放电和连续流蒸汽陷阱》.pdf
《NAVY MIL-T-960 E (3)-1991 TRAPS STEAM INTERMITTENT DISCHARGE AND CONTINUOUS FLOW NAVAL SHIPBOARD《海军舰间歇放电和连续流蒸汽陷阱》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-T-960 E (3)-1991 TRAPS STEAM INTERMITTENT DISCHARGE AND CONTINUOUS FLOW NAVAL SHIPBOARD《海军舰间歇放电和连续流蒸汽陷阱》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-T-SbOE (3) 47 999990b 0494538 9 a I INCH-POUND MIL-T-%OE( SH) AMENDMENT 3 30 October 1991 SUPERSEDING AMENDMENT 2 14 September 1981 MILITARY SPECIFICATION TRAPS, STEAM, INTERMITTENT DISCHARGE AND CONTINUOUS FLOW, NAVAL SHIPBOARD This amendment forms a part of MILT-%OE(SHIPS), dated 21 June 1963,
2、 and is approved for use by Naval Sea Systems Command, Department of the Navy and is available for use by all departments and agencies of the Department of Defense. PAGE 1 2.1, SPECIFICATIONS, MILITARY: Delete reference to: “MIL-D-%3“ and substitute “MILT-3100 - Technical Data Packages, General Spec
3、ification For“ and delete reference to “MIL-S-2953“. * 2.1, SPECIFICATIONS, MILITARY Delete “MILG-21032 - Gaskets, Metallic-Asbestos, Spiral Wound (for ASA Commercial Hanged Joints in Piping Systems) (Identification Symbol 2410)“ and substitute “MLG-24716 - Gaskets, Metallic-Flexible Graphite, Spira
4、l Wound.“ PAGE 2 3.1, delete and substitute: “3.1 Qualification. Steam traps (type I and II) furnished under this specification shall be products which are qualified for listing on the applicable qualified products list at time set for opening of bids (see 4.2 and 6.2)“ 3.2, line 2 Delete “as approv
5、ed“ and substitute “and shall be reviewed“, line 2, delete “Bureau of Ships“ and substitute “Naval Sea Systems Command (NAVSEA)“. AMSC NIA FSC 4730 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. lof6 Provided by IHSNot for ResaleNo reproduction or networking permit
6、ted without license from IHS-,-,-MIL-T-SbOE (3) 47 I SSS990b OLi94539 O E MIGT-%OE( SHIPS) AMENDMENT 3 1 E V I a E U I a 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-Sb0E (3) 47 H 9999906 0494540 7 6 MIL-T-%OE( SHIPS) AMENDMENT 3 Traps ser
7、ies PAGES 5 and 6 Minimum capacity pounds per hour Inlet pressure 20 OF depression 30 OF depression 3.3.4, first sentence: Delete. 100 150 Table IV, delete and substitute: 100 800 900 lo00 150 800 900 lo00 TABLE IV. Mutimum requirements for continuous discharge capacities of II2 inch traps at specif
8、ied temperature depressions with constant back pressure of 30 lblin. 150 150 lo00 1 100 300 300 lo00 1100 400 400 loo0 1100 600 600 loo0 1100 1500 1400 uxw) 2500 1300 1300 1300 1300 3Ooo I I 3.8.1.1, delete and substitute: 3.8.1.1 Series. Type I traps may be furnished in series 100 and 150 only.“ 3.
9、8.2, delete and substitute: “3.8.2 Type II. Type II traps may be furnished in all series except 100.“ Add as paragraph 3.8.3: “3.83 Type III. Type III traps may be furnished in all series.“ 3.9, delete and substitute: “3.9 Drawings. Drawings shall be furnished in accordance with MIL-T-31000.“ 3 Prov
10、ided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-9bOE (3) 47 99979Ob 0494543 7 R MIL-T-%OE( SHIPS) AMENDMENT 3 4.1, delete and substitute: “4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the contract
11、or is responsible for the performance of all inspection requirements as specified herein. Except as otherwise specified in the contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disap
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT960E31991TRAPSSTEAMINTERMITTENTDISCHARGEANDCONTINUOUSFLOWNAVALSHIPBOARD 海军 间歇 放电 连续流 蒸汽 陷阱 PDF

链接地址:http://www.mydoc123.com/p-982992.html