1、._ . I- -. . _ i -. MIL-T-82371 ACTD) 22 March 1971 SUPERSEDING MIL-T-82371 (TD) - 15 March 1968 MILITARY SPECIFICATION , TRAINING AID; DISPLAY PANEL, “M“ TYPE BOILER Training Device Center, Department of the Navy. This specification has been approved by the Naval - 1. SCOPE 1.1 This specification c
2、overs a panel-type of training aid to be used to demonstrate the principles of boi ler operation and show the arrangement of the main parts of an IM“ type boiler, used for generating superheated steam. .Center, as Device 29CC8B for Navy procurement (see 6.2). 2. APPLICABLE DOCUMENTS invitation for b
3、ids or request for proposal , form a part of this speci- fication to the extent specified herein: 1.1.1 This item has been designated, by the Naval Training Device 2.1 The following documents of the issue in effect on the date of I SPECIFICATIONS Federal W-C-596 - PPP-B-601 PPP-B-621 Mi 1 i tary MIL
4、-A-8625 MIL-P-I 16 MIL-L-10547 Connector, P1 ug , Electrical ; Connector, Receptacle, Electrical Boxes , Wood, Cleated-Plywood Boxes, Wood, Nailed and Lock-corner Anodic Coatings, For Aluminum and Al umi num Al 1 oys Preservati on : Method of Liners, Case and Sheet, Overwrap, Water-Vaporproof or Wat
5、erproof, Fl exi bl e FSC 6910 n Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-8237LA b9 m 777970b 0907928 5 W MIL-T-8237lpD) MI L-S-687 2 Sol deri ng Process, General Specification for . -. ;- -. MIL-T-23991 STANDARDS Mi 1 i tary Trai ni ng D
6、evi ces, Mi 1 i tary; General Speci fi cation for I MIL-STD-129 MIL-STD-143 Specifications and Standards; Order Marking for Shipment and Storage of Precedence for the Selection of (Copies of specifications, standards, drauings, an publications required by suppliers in connection with specific procur
7、ement functions should be obtained from the procuring activity or as directed by the Contracting Officer-.) 3. REQUIREMENTS and as specified in 3.1.1 through 3.1.5.1. transparency, optical clarity, and reststance to heat, shock and abrasion so as to perform in the training aid without visible imperf
8、ections or deteriora- tion. . 3.1 Materi al s. - Materi al used shall be in accordance wi th MIL-T-23991 3.1.1 Plastics.- Plastics used shall be acrylic, or a plastic of equal 3.7 .I .l Cements.- Cements or solvents for joining plastic components shall be those cements recommended by the manufacture
9、r of the plastics and tested by the contractor as suitable to meet the construction and performance requirements of this speci fi cati on. 3.1.1.2 C6enting.- Cemented plastic joints shall be free of air bubbles and stress crazing and shall have the transparency of the original plastic throughout the
10、 joint. The contact surface of the component to be cemented shall be thoroughly softened by means of a solvent, so that a soft layer or cushion is produced on that surface and subsequent uniting and hardening will effect a strong homogeneous bond. require. speci fi c written approval of the procuri
11、ng acti vi ty for each speci f i c vari ance for paint finishes. Wood shall be properly seasoned and free from checks, splits, and warp. Bonding by capi 11 ary attraction .shall 1 3.1.2 . Wood.- Wood shall be selected grades of hardwood lumber, suitable 3.1.2.1 Plywood.- Plywood shall be a minimum o
12、f five plies, or solid- core hardwood, both surfaces to be of. hardwood, all plies to be free of spaces or checks and joined. by waterproof glue. . . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M1L-T-82371A 67 m 7777906 oq07927 7 J I - _ - - - -
13、MIL-T-82371 (TD) 3.1,2.2 Glue.- Glue used shall not be adversely affected by moisture, 3.1.3 Hardboard.- Hardboard shall be of the tempered variety, smooth 1 acquer or pa3 nt . on both sides, hard surfaced and moisture resistant for a paint finish. U. S. Gypsum “Durontl or material equivalent in str
14、ength, rigidity and . smoothness of surface is acceptable. 3.1.4 Metals.- Metals shall be aluminum (type 6061) or be corrosion- resistant in accordance with corrosion-resistant metals requirements . . of MIL-T-23991. _ 3.1.4.1 All aluminum parts shall be anodized in accordance with 3.1.5 Paints.- Pa
15、ints used on metal surfaces shall be exterior 1 acquers 3.1.5.1 the acrylic surface. to ensure a reliable and permanent bond. 3.1.6 Written approval of the Procuring Contracting Officer shall be required for the selection of materials and parts from Standards and Speci- fications of MIL-STD-743, Gro
16、ups II, III and IV in accordance with non- standard materials and parts requirements of MIL-T-23991, MIL-A-8625. - Paints used on acrylic surfaces shall be compatible with - : . : .- : .- .C - . .- - I 3,2 Design.- The design of the training aid shall consist of a display panel , suitable for instru
17、cting students in the arrangement, heat balance and nomenclature of an M-type boiler for the generation of superheated steam. of heat in the boiler, a threeydimensional reduced scale stylized mockup of a section of the boiler, and a photograph showing a rendered perspective section through. the oper
18、ati onal boi 1 er. . 3.2.1 The display panel shall show a bar type diagram of the utilization 3.2.2 Power su 1 - The training aid shall operate from an external power source + of I 5 volts, 60 Hz. 3.2,2.1 The training aid shall be provided with a 20-foot, 3-wire. cable with plugs on each end, confor
19、ming to W-C-596, a cable receptacle, a main switch with red indicator light, and main 115-volt fusing. ,Stowage provisions for this cable shall be made on the inside of one of the rear doors of the training aid. 3.2.2.2 The lighting system of the display panel shall be powered from a 24 volts source
20、 supplied by a built-in step-down transformer. The 24-volt system shall be separately fused. 3.2.2.3 All wiring shall be identified by a color or number code. All wiring shall be neatly bundled and supported. A wiring diagram, enclosed in clear plastic by a pressure and heat sealing process, shall b
21、e attached to the inside of one of the rear doors of the training aid. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-T-82371 A(TD) .- 1- i 3.3 Reliability.- Reliability of operation shall be a prime consideration in the design and manufacture o
22、f the training afd. The design shall bfi such as to result in reduced requ-irements for adjustments and alinement, and low frequency of failure, while providing for simp1 ified maintenance. Replacement of parts shall be made easy, and accessibility for making adjustments or alinements or both shall
23、be provided. the training aid shall be constructed such that no fixed part, assemblies or subassemblies shall bind or become undesirably free, Degradation . shall not be caused in the mechanical or electrical performance stipulated for the training aid because of shipment, normal handling, or storag
24、e. The training aid shall withstand 5 hours use per week in a classroom for : a period of 5 years. the construction shall be in accordance with processes requirements In addition, 3.4 Construction.- Except as specified .in 3.4.1 of this specification, f MIL-T-23991. 3.4.1 Sol deri ng . - Sol dered c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILT82371A1971TRAININGAIDDISPLAYPANELMTYPEBOILER 展示 训练 辅助 器材 PDF

链接地址:http://www.mydoc123.com/p-982899.html