NAVY MIL-STD-2042-4 B-2002 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR NAVAL SHIPS (CABLEWAYS) (PART 4 OF 7 PARTS)《海军舰光缆拓扑装置标准方法》.pdf
《NAVY MIL-STD-2042-4 B-2002 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR NAVAL SHIPS (CABLEWAYS) (PART 4 OF 7 PARTS)《海军舰光缆拓扑装置标准方法》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-STD-2042-4 B-2002 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR NAVAL SHIPS (CABLEWAYS) (PART 4 OF 7 PARTS)《海军舰光缆拓扑装置标准方法》.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、METRICMIL-STD-2042-4B(SH)25 July 2002SUPERSEDINGMIL-STD-2042-4A(SH)29 September 1997MIL-STD-2042-4(SH)7 July 1993DEPARTMENT OF DEFENSESTANDARD PRACTICEFIBER OPTIC CABLE TOPOLOGY INSTALLATIONSTANDARD METHODS FOR NAVAL SHIPS(CABLEWAYS)(PART 4 OF 7 PARTS)AMSC N/A AREA GDRQDISTRIBUTION STATEMENT A. Appr
2、oved for public release; distribution is unlimitedProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-4B(SH)iiFOREWORD1. This Department of Defense Standard Practice is approved for use by theNaval Sea Systems Command, Department of the Navy
3、, and is available for use by allDepartments and Agencies of the Department of Defense.2. Beneficial comments (recommendations, additions, deletions) and anypertinent data which may be of use in improving this document should be addressedto: Department of the Navy, Naval Sea Systems Command, ATTN: S
4、EA 05Q, 1333 IsaacHull Avenue Southeast, Stop 5160, Washington Navy Yard, DC 20376-5160 by using theself-addressed Standardization Document Improvement Proposal (DD Form 1426)appearing at the end of this document or by letter.3. This standard practice provides detailed information and guidance toper
5、sonnel concerned with the installation of fiber optic cable topologies (opticalfiber cabling and associated components) on Naval surface ships and submarines. Themethods specified herein are not identifiable to any specific ship class or type,but are intended to standardize and minimize variations i
6、n installation methods toenhance the compatibility of the installations on all Naval ships.4. In order to provide flexibility in the use and update of the installationmethods, this standard practice is issued in eight parts; the basic standardpractice and seven numbered parts as follows:Part 1 Cable
7、sPart 2 EquipmentPart 3 Cable PenetrationsPart 4 CablewaysPart 5 Connectors and InterconnectionsPart 6 TestsPart 7 Pierside Connectivity Cable Assemblies and Interconnection HardwareProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-4B(SH)i
8、iiCONTENTSPARAGRAPH PAGE1. SCOPE 11.1 Scope . 11.1.1 Applicability . 12. APPLICABLE DOCUMENTS . 22.1 General . 22.2 Government documents 22.2.1 Specifications, standards and handbooks . 22.2.2 Other Government documents 22.3 Non-Government documents 22.4 Order of precedence . 33. DEFINITIONS 43.1 Ge
9、neral fiber optics terms 43.2 Acronyms 43.3 Alternate channel . 43.4 Authorized approval . 43.5 BOF bundle 43.6 BOF fiber . 43.7 BOF tube 43.8 BOF tube coupler 43.9 BOF tube routing box 43.10 End user equipment 43.11 Fiber optic cable plant (FOCP) 43.12 Fiber optic cable topology 43.13 Fiber optic i
10、nterconnection box (FOICB) . 43.14 Installing activity . 43.15 Local cable . 53.16 Minimum bend diameter . 53.17 Non-redundant channel (NRC) . 53.18 Normal channel 53.19 Optical fiber cable . 53.20 Optical fiber cable component (OFCC) 53.21 Outlet box 53.22 Trunk . 53.23 Trunk cable . 53.24 Tube fur
11、cation unit . 54. GENERAL REQUIREMENTS . 64.1 Location of optical fiber cable runs 64.1.1 Main fore and aft cable runs 64.1.1.1 Surface ships . 64.1.1.2 Submarines 64.1.2 Vertical cable runs . 64.1.3 Optical fiber local cable runs 64.1.4 Cable runs with special requirements 64.1.4.1 Control from mor
12、e than one location . 64.1.4.2 Control by two cables from one location . 74.1.4.3 Cables containing redundant fibers 74.1.5 Protection of cable . 74.1.5.1 Protection from battle damage . 74.1.5.2 Protection from mechanical damage . 74.1.5.2.1 Protection in cargo spaces 74.1.5.2.2 Protection in riser
13、 boxes and multiple cable penetrators 7Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-4B(SH)ivCONTENTSPARAGRAPH PAGE4.1.5.2.3 Protection on an oiler weather deck. 84.1.5.2.4 Special protection for BOF cables. 84.1.5.3 Protection from th
14、e weather . 84.1.5.4 Protection from excessive heat 84.1.5.5 Protection from excessive moisture 84.1.6 Cable runs through bilges, submerged spaces and voids . 84.1.7 Cable runs in hazardous locations . 84.1.8 Cable runs in hangar spaces (aircraft carriers) . 84.1.9 Cable runs to gun mounts and direc
15、tors 84.1.10 Cable runs to rotating missile launchers 84.2 Installation of optical fiber cables in cableways . 94.2.1 Cable pulling . 94.2.2 Cable pulling in armored cable cableways 94.2.3 Cable bend diameter . 94.2.3.1 Conventional optical fiber cable minimum bend diameters . 94.2.3.2 BOF cable min
16、imum bend diameters 94.2.4 Installed cable slack . 94.2.5 Cable placement in cable hangers . 104.2.6 Installation on bulkheads and overheads 104.2.6.1 Cable hangers and supports . 104.2.7 Installation on ballistic structures . 104.2.8 Double banking of cable 104.2.9 Cable retention 114.2.10 Cable ta
17、gs . 114.2.11 Dead-ended cable . 114.2.12 Temporary exposure of BOF cables to excessive heat . 114.3 Electric cable installation over fiber cable . 114.4 Cableways 114.4.1 Spare cable allowance 124.5 Fiber optic cable topology test 124.6 BOF bundle and BOF fiber installation 124.7 Safety precautions
18、 . 125. DETAILED REQUIREMENTS . 145.1 Cableways 145.1.1 Cableways (submarines) . 145.1.2 Cableways (surface ships) 145.1.3 Cableways (general) 145.1.4 Cable protection . 146. NOTES . 156.1 Intended use . 156.2 Issue of DODISS 156.3 Subject term (key word) listing 15Provided by IHSNot for ResaleNo re
19、production or networking permitted without license from IHS-,-,-MIL-STD-2042-4B(SH)11. SCOPE1.1 Scope. This standard practice provides detailed methods for installingoptical fiber cable cableways and cable protection on surface ships and submarines.1.1.1 Applicability. These criteria apply to instal
20、lations on specific shipswhen invoked by the governing ship specification or other contractual document.They are intended primarily for new construction; however, they are also applicablefor conversion or alteration of existing ships. The rapidly changing state of theart in fiber optic technology ma
21、kes it essential that some degree of flexibility beexercised in enforcing this document. When there is a conflict between thisdocument and the ship specification or contract, the ship specification or contractshall take precedence. Where ship design is such that the methods herein cannot beimplement
22、ed, users shall submit new methods or modifications of existing methods forapproval prior to implementation to: Department of the Navy, Naval Surface WarfareCenter, Dahlgren Division, ATTN: Code B35, 17320 Dahlgren Road, Dahlgren, VA 22448-5100.Provided by IHSNot for ResaleNo reproduction or network
23、ing permitted without license from IHS-,-,-MIL-STD-2042-4B(SH)22. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified in sections3, 4 and 5 of this standard practice. This section does not include documents citedin other sections of this standard practice or recommend
24、ed for additionalinformation or as examples. While every effort has been made to ensure thecompleteness of this list, document users are cautioned that they must meet allspecified requirements documents cited in sections 3, 4 and 5 of this standardpractice, whether or not they are listed.2.2 Governm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILSTD20424B2002FIBEROPTICCABLETOPOLOGYINSTALLATIONSTANDARDMETHODSFORNAVALSHIPSCABLEWAYSPART4OF7PARTS

链接地址:http://www.mydoc123.com/p-982375.html