NAVY MIL-R-28881 (2)-1986 RADIACMETER IM-239 WDQ《IM-239 WDQ型辐射仪》.pdf
《NAVY MIL-R-28881 (2)-1986 RADIACMETER IM-239 WDQ《IM-239 WDQ型辐射仪》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-R-28881 (2)-1986 RADIACMETER IM-239 WDQ《IM-239 WDQ型辐射仪》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 NIL-R-ZBBBL (2) bb 7777906 0236515 5 flIL-R-28881( AMENDMENT 2 EC) t 31 January 1986 UPtRSmING AMENDMENT 1 25 February 1985 MI L I TARY SPEC IF I CAT I ON RADIACMETER , IM-239/WDQ Th is amendment forms a part of Mi 1 itary Specification MIL-R-28881(EC), dated 26 March 1984, and is approved for use
2、by the Space and Naval Warfare Systems Comnand, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 2.1.1, line 2: Delete “the“ before “listed“. 2.1.1 , “SPEC IF ICATIONS“ , “MILITARY“ : 2.1.1, “STANDARDS“, “MILITARY“: Delete “MIL-STD
3、-810 Environmental Test Methods And Engineering De lete “MIL-R -28760 Rad i acmeter , A ir Part ic 1 e Detector , IM-192/WDQH. Gu iUel ines“ and substitute “MIL-STD-810C Environmental Test Methods“. PAGE 2 3.2.1, 1 ine 2: Add “dimensional“ before “environment“. PAGE 3 * FIGURE 1: Delete and substitu
4、te the attached new FIGURE 1. PAGE 4 FIGURE 2: Delete “17.0“ and substitute “17.00 10.10“. FIGURE 2: Delete “2 3/32“ and substitute “23/32“. 3.3.1.1, line 3: 3.3.1.1, lines 3 and 4: Delete “end points beta“ and substitute “beta end point energies“. Delete “megaelectronvolts“ and substitute “million
5、electron-volt“. PAGE 5 FIGURE 3: Delete 17.00 k.031“ and substitute 17.00 10.10“. 3.3.1.5, after the last sentence, add: “The radiacmeter may start up with a preset alarm value of i x 10-:. 3.3.1.6: Delete the text and substitute: “The range of detection shall be linear such that the total system er
6、ror shall not exceed *lo percent from actual radioactivity from 2 x 1 x pCi/ml and *15 percent in the last range from 1 x to 1 x uCi/ml. Any reading within the five decades of rangeshall be capable of being read on the front console.“. to 3.3.1.8. lines 2 and 3: Delete shall be equal to or greater t
7、han“ and substitute “may be equal to“. . PAGE 6 3.3.1.9, line 5: Delete “such a“ and substitute “such as“. 3.3.2.3: Delete the text and substitute: “The radiacmeter shall fit the mounting holes as dimensioned in FIGURE 2. specified in MS16142.“. The air inlet and outlet ports shall use 7/8-14 UNF-28
8、 fittings as 3.3.4.2.1a. 1 ne 3: Delete “bave“ and substitute “have“. 1 OfX AblSC NIA . /THIS DOCUMENT CONTAINS LG- PAGES. FSC 6665 .y “Y 3-6-86/700 DISTRIBUTION STATEMENT A. Approved for pub1 ic release; distribut ion is un1 imited. - . -.- Provided by IHSNot for ResaleNo reproduction or networking
9、 permitted without license from IHS-,-,-MIL-R-28881( EC) AMENDMENT 2 PAGE 7 3.3.4.2. IC, 1 ine 2: 3.3.4.2.3b, line 4: After Vest jacks“ add “or connectors“. 3.3.5.2, lines 2 and 3: Delete “OC to 60C“ and substitute “5C to 50C“. 3.3.5.2, 1 ine 3: Delete “4.5.16.2“ and substitute “4.5.16.2.2“. Delete
10、“air regulation and cut-off“ and substitute “paper feed“. PAGE 8 3.3.5.3.2, line 3: Delete “be designed to“. 3.3.5.3.2, third sentence: Delete and subst the steam pressurization transient specified in 3 3.3.5.3.2, last sentence: Delete. 3.4, line 1: Delete “3.4“ and substitute “3 3.4.1, line 2: Dele
11、te “3.4.1“ and substitut tute “The sealed sampling system sha 3.5.3.4.“. 4.1“. “3.4.1.1“. PAGE 9 3.4.7.6, second sentence: Delete. 1 contain . 3.4.7.6, line 3: Delete “may be“ and substitute “shall be“. 3.4.7.7, 1 ne 2: Add “radiacineters“ before “power supply“. PAGE 10 3.4.9d: Add “including front
12、panel“. 3.4.9.1, line 2: 3.4.9.1, line 4: Delete “positon“ and substitute “position“. 3.4.9.1, line 5: Delete “24 hours“ and substitute “8 hours“. 3.4.9.1, after the last.sentence, add: 3.4.9.3: Delete “is filtered through. “ and substitute “passes through the filter paper. I. “A minimum of 75 feet
13、of filter paper will be provi ded.“. multiplier tube and process and amplify each pulse so that the pulses can be counted by the microprocessor. panel.“ Add “The preamp1 if er assembly shall receive the electrical pulses from the photo- Discr imination against electrical noise pulses shall be provid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILR2888121986RADIACMETERIM239WDQIM239WDQ 辐射 PDF

链接地址:http://www.mydoc123.com/p-981245.html