1、MIL-R-L8LI28A 66 = 7779906 0229728 9 m MIL-R-18428A (SHLPS) 2 January 1956 SUPERSEDING MIL-T- 18428(SHIPS) 14 February 1955 MILLTARY SPECIFICATION RADIO SET AN/URN-3, TEST EQUIPMECNT FOR 1. SCOPE 1.1 This specification covers several items of special test equipment which will normally be packaged wi
2、th Radio Set AN/URN-3 to permit a high degree of preventive maintenance and calibration and to insure the greatest possible operational reliability for the basic equipment. 2. APPLICABLE DOCUMENTS 2.1 The following specifications and standards, of the issue in effect on date of invitation for SPECIF
3、ICATIONS bids, form i, part of this specification: MILITARY MIL-C-3098 - Crystal Units, Quartz. MIL-E-15090 - Enamel, Equipment, Light-Gray (Formula No. 111). MIL-E-16400 - Electronic Equipment, Naval Ship and Shore: MIL-T-17113 - Tests; Shock, Vibration, and Inclination(for Electronic MIL-E-17555 -
4、 Electronic Equipment and Associated Maintenmce Parts; General Specification. Equipment) General Specification. Preservation, Packaging, Packing, and Marking of, NAVY DEPARTMENT General Specifications for Inspection of Material. STANDARDS MILITARY MIL-STD-108 - Definitions of and Basic Requirements
5、for Enclosures for Electric and Electronic Equipment. (Copies of specifications, standards, drawings, and publications required by contractors in connection with specific procurement functions should be obtained from the procuring agency or as directed by the contracting officer. ) I 1 I FED. SUP. C
6、LASS 6625 I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-R-18428A (SHIPS) 3. REQUIREMENTS 3.1 Reliability. - An extermely high degree of reliability is required for all items furnished. The use of electronic parts and electron tubes, under con
7、servative operating conditions, such as moderate voltages and dissipations, is recommended. 3.2 General. - 5.2.1 This specification covers the requirements for special purpose test equipment which will be installed in Radio Set AN/URN-3 equipment cabinets, as are being furnished the bureau or agency
8、 concerned, and shall meet the requirements of Specification MIL-E-16400, except as otherwise specified herein. 3.2.2 Materials and parts which represent an improvement in the state of the art over materials and parts covered by applicable specifications shall be used to increase reiability, reduce
9、size arid weight, and reduce the effects of heating, Approval of such materials and parts shall be in accordance with Specification MIL-E -16400. Particular attention shall be paid to the acceptable and unacceptable material requirements of Specification MIL-E-16400. 3.2.3 Enclosure. - The equipment
10、 shall have a dripproof degree of enclosure in accordance with Standard MIL-STD-108 when installed in the AN/URN-S equipment cabinets. 3.2.4 Shack requirements, - The equipment shallwithstand shock tests in accordance with class A of Specification MIL-T-17113 when installed in the AN/RN-3 equipment
11、cabinets. The contractor shall repair any and all damages resulting from the tests. in accordance with class 1 of Specification MIL-E-16400. 3.2.6 Temperature, - All major units of the special test equipment shall operate satisfactorily within the limits of this specification in ambient temperatures
12、 of O” to 40” Centigrade (C.) and within twice the tolerance limits in the ambient temperature ranges of minus 28” to 0C. and plus 40” to plus 50C, All units shall remain operable and useful from minus 54” to plus 75”C., although not necessarily within the operational tolerances stated herein, This
13、paragraph applies to test equip- ment installed in the AN/URN-3 equipment cabinets with the AN/URN-3 equipment turned on. 3.2.5 Operating conditions. - Special test equipment shall be capable of continuous operation 3.2.7 Power source, - The equipment shall be capable of operation from a 12O-volt, 6
14、0-cycle source, Major units shail be capable of satisfactory continuous operation with variations of plus or minus 10 percent in line voltage and plus or minus 5 percent in cycles in frequency. Momentary impairment of operation due to a plus or minus 30 percent transient of 1 second duration will be
15、 permissible, but shall not cause failure of parts or prevent resumption of normal operation when the transient has ceased, 3.2.8 Control locking devices. - The design of control locking devices shall be in accordance with Specification MIL-E-16400. 3.2.9 Connectors. - External RF connections shall
16、be made through type “C” or (BNC” con- nectors. Associated external RF cable jacks and plugs shall be furnished and except for front panel connections shall be capable of clamping armor. External video connections shall be made through type connectors, except those used.in the interconnecting harnes
17、s which shall be of the AN” or (BNC” type. Interconnecting harness connectors shall be placed at the rear of the test equip- ment drawers so that the harness may be directly installedin the AN/URN-3 equipment cabinets. 2 - - Provided by IHSNot for ResaleNo reproduction or networking permitted withou
18、t license from IHS-,-,-MIL -R - 18428A (SHIPS) 3.2.10 Tropicalization. - Tropicalization will not be required. 3.2.11 Blown fuse indicators. - Blown fuse indicators shall be provided. 3.3 Detail requirements. - 3.3.1 The equipment shall be designed for use in the AN/URN-3 equipment cabinets, The AN/
19、URN-3 equipment cabinets are serviced from the front only, and special test equipment shall be constructed in a manner mechanically consistent with the design used in the AN/URN-3. The dimensions and location of special test equipment shall be determined by the contractor for the AN/URN-3. 3. 3.2 Sp
20、ecial test equipment assemblies. - The equipment shall consist of the following five main assemblies: Major units Reference Oscilloscope OS - 5 4/URN - 3 Pulse analyzer - Signal Generator TS-89O/URN-3 Generator, Pulse-Sweep SG-12lA/URN-3. 3.3.5 Switch-Tes Adapter SA-420/URN-3. 3.3.7 3.3.3 3. 3.4 3.3
21、.6 Power meter - Pulse Counter TS-891/URN-3 The four major units, reference3.3.3through 3.3.6, are individually packaged (except for shock- mounting and dripproofing, which is accomplished when the assemblies are placed in the AN/Um-3 cabinets) and capable of operating independently. The switch test
22、 adapter which is mounted separately from the AN/URN-3 cabinets shall meet the full packaging requirements. 3.3.2.1 The general appearance of the front panels, the dripproofing treatment and the color shall be compatible with the front panels of the AN/URN-3. External finish coats shall be enamel co
23、nforming to class 2 of Specification MIL-E-15090. 3.3.2.2 Preset testing positions. - The special test equipment shall include two function switches of four positions each, labeled identically such that when set to corresponding positions, the appropriate interconnections among the test equipment un
24、its and the AN/URN-3 will be made to perform all normal testing. These switches shall be located as follows: one on the power meter puise counter unit and one on the oscilloscope. The four positions shall be as shown in tableI. Table I - Preset testing positions. Position : Marking Tests 1 I Operati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILR18428A1956RADIOSETANURN3TESTEQUIPMENTFOR 辐射 ANURN3 实验 设备 要求 PDF

链接地址:http://www.mydoc123.com/p-981108.html