NAVY MIL-PRF-85725 A-1998 RACK INTEGRATED AVIONICS FORCED AIR COOLED GENERAL SPECIFICATION FOR《强迫风冷综合航空电子设备的机架的一般规定》.pdf
《NAVY MIL-PRF-85725 A-1998 RACK INTEGRATED AVIONICS FORCED AIR COOLED GENERAL SPECIFICATION FOR《强迫风冷综合航空电子设备的机架的一般规定》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-85725 A-1998 RACK INTEGRATED AVIONICS FORCED AIR COOLED GENERAL SPECIFICATION FOR《强迫风冷综合航空电子设备的机架的一般规定》.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-PRF-85725A m 999990b 2065708 957 m * MIL-PRF-S5725A(AS) 20 Mav 1998 SUPERSEDING 25 July 1986 MIL-R-85725(AS) PERFORMANCE SPECIFICATION RACK, INTEGRATED AVIONICS, FORCED AIR COOLED, GENERAL SPECIFICATION FOR This specification is approved for use by the Naval Air Systems Command, Department of th
2、e Navy, and is available for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers forced-air-cooled, integrated avionics racks, herein after referred to as racks, used for various military avionics systems. The racks are designed to accommod
3、ate Standard Electronic Modules (SEMS) using multiple tiers. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for add
4、itional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet ail specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government document
5、s. Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Naval Air Warfare Center Aircrafk Division, Code 414100B120-3, Highway 547, Lakehurst, NJ 08733-5100 by using the Standardization Do
6、cument Improvement Proposal D Form 1426) appearing at the end of this document or by letter. AMSC NA FSC 5975 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-57
7、25A 99999Ob 20b5709 893 MIL-PRF-8 5 72 5A( AS) 2.2.1 Soecifications. standards and handbooks. The following specifications, standards and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of
8、the Department of Deferse Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-C-28754 - Connectors, Electrical, Modular, Component Parts, General Specification For MIL-C-3 8999 - Connector, Electrical, C
9、ircular, Miniature, High Density, Quick Disconnect, Bayonet, Threaded, and Breach Coupling, Environment Resistant, Removable Crimp and Hermetic Solder Contacts, General Specification For STANDADS DEPARTMENT OF DEFENSE MIL-STD-130 - Identification Marking of U.S. Military Property MIL-STD-8 1 O - Env
10、ironmental Test Methods and Engineering Guidelines MIL-STD-1377 - Effectiveness of Cable, Connector, and Weapon Enclosure Shielding and Filters in Precluding Hazards of Electromagnetic Radiation to Ordnance; Measurement of MIL-STD-13 89 - Design Requirements for Standard Electronic Modules (Unless o
11、therwise indicated, copies of the above specifications, standards, and handbooks are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 191 11-5094.) 2.3 Non-Government publications. The following document forms a part of this document to the ex
12、tent specified herein. Unless otherwise specified, the issues of the documents which are DoD adopted are those listed in the issue of the DoDISS cited in the solicitation. Unless otherwise specified, the issues of documents not listed in the DoDISS are the issues of the documents cited in the solici
13、tation (see 6.2). AMERICAN SOCIETY FOR QUALITY CONTROL (ASQC) ASQC-Zl.4 - Sampling Procedures and Tables for Inspection by Attributes. OD adopted) 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NIL-PRF-85725A = 999990b 2065710 505 (Application for
14、 copies should be addressed to the American Society for Quality Control, 61 1 East Wisconsin Avenue, Milwaukee, WI 53202.) 2.4 Order of precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in thi
15、s document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specified (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.2. 3.2 Materials. The materials used in the constru
16、ction of racks shall be capable of meeting the performance requirements specified herein (see 3.3.11.2 and 4.5.1). 3.2.1 Corrosion prevention and control. The materials selected shall have corrosion resistance or shall be treated to resist corrosion during service life (see 6.2). 3.2.2 Dissimilar me
17、tals. Where dissimilar metals are used in contact with each other, protection against galvanic corrosion shail be provided. When dissimilar metals are used they shall not be susceptible to galvanic corrosion in accordance with table VI1 of MIL-C-28754. Dissimilar metals such as brass, copper or stee
18、l shall not be used in contact with aluminum or aluminum alloys. 3.2.3 Recycled. recovered. or environmentally preferable materials. Recycled, recovered, or environmentally safe materials shall be used, provided that the material meets the performance requirements specified herein. 3.3 Design. 3.3.1
19、 Modularity. The rack shall accommodate two to seven tiers (see 6.2). Each tier shall be compatible with either Format B span 2, Format C, or Format E modules as specified in MIL-STD-1389. Each tier shall also contain a primary backplane. The individual tiers shall interconnect with a flexible secon
20、dary backplane. Each tier shall: a: Have a primary backplane through which the SEMS are interconnected. b. Have a combination module guide rail and air heat exchanger for module retention and heat dissipation. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fro
21、m IHS-,-,-. c. Provide module retainer mechanisms to secure the modules firmly in place and provide for thermal contact with the guide rail. d. Be removable as an assembly, complete with module guide rail and heat exchangers, fiom the front of the rack. e. Provide a means to ailow the escape of wate
22、r or other fluids fiom the module equipment. 3.3.2 Backplanes. All electrical connections between modules, tiers, and inputoutput WO) connectors shall be through backplanes. 3.3.2.1 Primary backplane. The primary backplane shall provide the electrical and mechanical interconnection for the modules (
23、see figure 1). 3.3.2.2 Secondary backplane. The secondary backplane shall provide an interconnection medium for rack YO connectors, primary backplanes, and other associated electrical components. 3.3.3 Connectors: Electrical connections shall consist of the connector types specified in 3.3.3.1 and 3
24、.3.3.2. 3.3.3.1 Inputoutput connectors. The rack shall accommodate connectors as specied in MIL-C-38999. Locations shall be provided at the ends which are not plenums of the rack for I/O connector mounting. The I/O connectors and secondary backplane shall be removable fiom the inside of the enclosur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF85725A1998RACKINTEGRATEDAVIONICSFORCEDAIRCOOLEDGENERALSPECIFICATIONFOR 强迫 风冷 综合 航空 电子设备 机架

链接地址:http://www.mydoc123.com/p-981083.html