NAVY MIL-PRF-2818D-2004 INSULATION BLANKET THERMAL.pdf
《NAVY MIL-PRF-2818D-2004 INSULATION BLANKET THERMAL.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-PRF-2818D-2004 INSULATION BLANKET THERMAL.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、 AMSC N/A FSC 5640 INCH-POUND MIL-PRF-2818D 14 October 2004 SUPERSEDING MIL-I-2818C 9 April 1992 PERFORMANCE SPECIFICATION INSULATION BLANKET, THERMAL This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification establish
2、es the requirements for a metal mesh reinforced thermal insulation blanket. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in sections 3, 4, or 5 of this specification. This section does not include documents cited in other sections of this specification or r
3、ecommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they must meet all specified requirements of documents cited in sections 3, 4, or 5 of this specification, whether or not they are listed.
4、 2.2 Government documents. 2.2.1 Specifications, standards and handbooks. The following specifications, standards, and handbooks form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract. Com
5、ments, suggestions, or questions on this document should be addressed to Commander, Naval Sea Systems Command, ATTN: SEA 05Q, 1333 Isaac Hull Avenue, SE, Stop 5160, Washington Navy Yard DC 20376-5160 or emailed to commandstandardsnavsea.navy.mil, with the subject line “Document Comment“. Since conta
6、ct information can change, you may want to verify the currency of this address information using the ASSIST Online database at www.dodssp.daps.mil Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-2818D 2DEPARTMENT OF DEFENSE STANDARDS MIL-STD-
7、1623 - Fire Performance Requirements and Approved Specifications for Interior Finish Materials and Furnishings (Naval Shipboard Use). (Copies of these documents are available online at http:/assist.daps.dla.mil/quicksearch or www.dodssp.daps.mil or from the Standardization Document Order Desk, 700 R
8、obbins Avenue, Building 4D, Philadelphia, PA 19111-5094.) 2.2.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these do
9、cuments are those cited in the solicitation or contract. BUREAU OF MEDICINE AND SURGERY (BUMED) BUMED INST 6270.8 - Procedures for Obtaining Health Hazard Assessments Pertaining to Operational Use of a Hazardous Material. (Copies of this document are available online at https:/bumed.med.navy.mil or
10、from Bureau of Medicine and Surgery, Department of the Navy, 2300 E Street, NW, Washington, DC 20372-5300.) NAVAL SEA SYSTEMS COMMAND (NAVSEA) S9510-AB-ATM-010 Rev 2 of 30 July 1992 - Nuclear Powered Submarine Atmosphere Control Manual. (Copies of this document are available from the Naval Sea Syste
11、ms Command, Code SEA 05Z9, 1333 Isaac Hull Avenue, SE, Stop 5133, Washington Navy Yard DC 20376-5133.) 2.3 Non-Government publications. The following documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in th
12、e solicitation or contract. ASTM INTERNATIONAL C 167 - Standard Test Methods for Thickness and Density of Blanket or Batt Thermal Insulations. (DoD adopted) C 177 - Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Appa
13、ratus. (DoD adopted) C 411 - Standard Test Method for Hot-Surface Performance of High-Temperature Thermal Insulation. (DoD adopted) C 447 - Standard Practice for Estimating the Maximum Use Temperature of Thermal Insulations. C 592 - Standard Specification for Mineral Fiber Blanket Insulation and Bla
14、nket-Type Pipe Insulation (Metal-Mesh Covered) (Industrial Type). (DoD adopted) C 665 - Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing. (DoD adopted) C 892 - Standard Specification for High-Temperature Fiber Blanket Thermal I
15、nsulation. (Copies of these documents are available from www.astm.org or ASTM International, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-2818D 32.4 Order of precedence. In the even
16、t of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First article. When specifie
17、d (see 6.2), a sample shall be subjected to first article inspection in accordance with 4.2. 3.2 Material. The thermal insulation blanket material when specified (see 6.2), shall be secured between metallic supporting members. The insulation material shall contain neither asbestos nor ceramic (refra
18、ctory) fiber. 3.3 Physical requirements. The insulation material shall conform to the physical requirements specified in Table I. 3.3.1 Recycled, recovered, or environmentally preferable materials. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent poss
19、ible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs. TABLE I. Physical requirements. Characteristic Requirement Test Method Non-fibrous material (shot content) percent by weight, max. Alkalinity percen
20、t, max. Corrosiveness to steel, copper, and aluminum Binder content, percent, max. Density lb/ft3 (without supporting metal facings) Thermal conductivity (K) Max. Btu in/hr. sq. ft. degree Fahrenheit at a mean temperature of 200F 400F 600F Moisture absorption, percent, max. 20 0.6 No corrosion great
21、er than that observed with sterile cotton 1.5 8-12 0.31 0.44 0.60 1.25 4.5.1 4.5.2 4.5.3 4.5.4 4.5.5 4.5.6 4.5.7 3.4 Dimensions. The length, width and thickness of the insulation blanket shall be as specified (see 6.2). The tolerances shall be plus 1/4 inch and minus 1/8 inch for thickness, plus or
22、minus 1/2 inch for length and plus or minus 1/4 inch for width. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-2818D 43.5 Supporting members. The supporting members shall consist of stainless steel wire mesh on both sides of the insulations
23、or wire mesh on one side and metal lath on the other side or without supporting members, as specified (see 6.2 and 6.9) 3.6 Resistance to vibration. The insulation blanket shall not, after heating/vibration, lose more than 15.0 percent in mass, nor sag an average of more than 3 inches (see 4.5.8). T
24、here shall be no detrimental affect to the overall physical characteristics of the blanket when comparing to a control specimen. For example, bolts cutting through the insulation material which cause large quantities of fiber or insulation blanket pieces to drop off the test stand holder during or a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILPRF2818D2004INSULATIONBLANKETTHERMALPDF

链接地址:http://www.mydoc123.com/p-980965.html