1、-3 MIL-P-82866 13 = 999990b 0473900 5 I INCH-POUND I MIL-P-82866(0S) 27 March 1991 SUPERSEDING WS 13643A 18 June 1979 MILITARY SPECIFICATION PRIMER, ELECTRIC, MARK 153 MOD 1 This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by a
2、ll Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. This specification establishes the minimum requirements for the Electric Primer, Mark 153 Mod 1, herein referred to as the “primer.“ 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications and standards. The
3、 following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards ODISS) and supplement thereto, cited in the
4、solicitation (see 6.2). SPECIFICATIONS FEDERAL PPP-B-636 Boxes, Shipping, Fiberboard MILITARY MIL-D-3464 Desiccants, Activated, Bagged, Packaging Use and Static Dehumidification Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this d
5、ocument should be addressed to: Commanding Officer, Naval Ordnance Station, Standardization Branch (Code 3730), Indian Head, MD 20640-5000 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or sending a letter. AMSC NIA DISTRIBUTION STATEM
6、ENT A. Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-828bb 13 W 9999906 0473901 7 W MIL-P-82866(OS) STANDARDS MILITARY MIL-STD-129 Marking for Shipment and Storage MIL-STD-33 1 Fuze and
7、Fuze Components, Environmental and Performance Tests for MIL-STD-453 Inspection, Radiographic MIL-STD-1167 Amunition Data Card MIL-STD-1168 Ammunition Lot Numbering DOD-STD-2101 Classification of Characteristics (Unless otherwise indicated, copies of federal and military specifications and military
8、standards are available from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 191 11-5094.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to th
9、e extent specified herein. Unless otherwise specified, the issues are those cited in the solicitation. DRAWINGS NAVAL SEA SYSTEMS COMMAND (CAGE CODES 10001 AND 5371 1) 2847639 Primer, Electric, Mark 153 Mod 1 50 12985 Charge, Propelling, 5-Inch, 54 Caliber, Reduced, Mark 68 Mod 2 5166058 Pack, Prime
10、r, MK 43 Mod 1, Primers for Gun Cartridges, 5-Inch and Larger 5 166059 Shipping Condition, Primer for Gun Cartridges, 5-Inch and Larger in Pack, Primer, Mk 43 Mod 1 (Application for copies of NAVSEA drawings should be addressed to: Commanding Officer, Naval Ordnance Station, Attn; Code 802, Louisvil
11、le, KY 40214.) PUBLICATIONS NAVAL SEA SYSTEMS COMMAND (CAGE CODE 10001) OD 49540 Functioning Test of Electric Primers 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-z -. MIL-P-828bb 13 m 99999Ob 0473902 9 m - r- MIL-P-82866(OS) (Application for co
12、pies of ODs should be addressed to: Commanding Officer, Naval Ship Weapons Systems Engineering Station, NAVSEA Data Support Activity (Code 5H30), Port Hueneme, CA 93043 .) “R-531884 Palletizing Domestic Unit Load (Application for copies of WRs should be addressed to: Commanding Officer, Naval Public
13、ations and Forms Center, (ATN: PODS), 5801 Tabor Avenue, Philadelphia, PA 19120-5099.) CODE OF FEDERAL REGULATIONS (CFR) 49 CFR 100-199 Transportation me Code of Federal Regulations is available from the Superintendent of Documents, US Government Printing Office, Washington, DC 20402.) 2.2 Order of
14、precedence. In the event of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 First
15、 article. When specified (see 6.2), a sample shall be subjected to first article inspection (see 6.4) in accordance with 4.4. 3.2 Characteristics. The primer shall conform to all requirements specified herein and on Drawing 2847639 and associated documents. *e 3.3 Radiographic (M101). The primer sha
16、ll not exhibit any discernible gaps as identified in figure 1 (see 4.7.1 1. Gap no. 3 FIGURE 1. GaD identification. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.4 Black powder moisture content (M102). The moisture content of the black powder w
17、ithin the primer shall not exceed 0.70 percent by weight (see 4.7.2). 3.5 Detail strip. The primer and ail its components shall conform to the following requirements (see 4.7.3): a. (Ci) Each criticai.characteristic shall be as specified in the applicable documents listed on Drawing 2847639 and in t
18、his specification. b. (M103) Each major characteristic shall be as specified in the applicable documents listed on Drawing 2847639 and in this specification. 3.6 Electrical resistance (M104). The primer shall have an electrical resistance of O. 10 to O. 18 ohm (see 4.7.4), 3.7 Functional. The primer
19、 shall meet the following criteria (see 4.7.5): a. (M105) Primer functioning time shall be a maximum of 0.006 second; b. (M106) The primer shall not misfire (see 6.7.1); c. (M107) The primer shall not exhibit blowback (see 6.7.2); and d. (C2) The primer shall not exhibit a split stock, split tube, o
20、r detachment of metallic components other than blowout of ignition element closing discs. 3.8 Vibration, The primer shall meet the following requirements (see 4.7.6): a. (C3) The primer shall not function during vibration; b. (C4) The stock and tube shall maintain material integrity and the primer s
21、hall maintain assembly integrity at the mating threads of the stock and tube during vibration; c. (M108) The primer shall not otherwise physically breakdown during vibration; d. The primer shall meet the requirements of 3.6 after vibration; and e. The primer shall meet the requirements of 3.7 after
22、vibration. 3.9 Ballistics. The primer when assembled into a 5“/54 propelling charge shall provide ignition which will meet the criteria of 3.7 b., c., and d. and the following (see 4.7.7): a. (M109) The ejection time of the projectile from the gun barrel shall not be greater than 0.050 second after
23、application of firing energy. 4 MIL-P-828bb 13 m 999990b 0473903 O m 3 I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-. r -. MIL-P-828bb 13 M 777770b 0473704 2 = 3.10 Workmanship. All parts shall be free of chips, dirt, grease, rust, and all other
24、 foreign material. There shall be no burrs or other imperfections of manufacture which would affect the assembly, functioning, or handling of the product. The cleaning methods used shall not be injurious to any of the parts, nor shall the parts be contaminated by the cleaning agents. All markings sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILP828661991PRIMERELECTRICMARK153MOD1MARK153MOD1 雷管 起爆 药包 PDF

链接地址:http://www.mydoc123.com/p-980831.html