1、MIL-P-2457 13 77777Ob Oq33710 b P 5. F Code Ident MIL-P-82459 (OS) 10001 28 July 1966 Superseding WS-4829 MILITARY SPECIFICATION 3 May 1966 i i PRESSURE TRANSDUCER r- $i! (For Torpedo MK46 Mod O and Mod.1) 1. SCOPE 1.1 This specification covers requirements for the procurement of one type I of press
2、ure transducer (see 6,l. 2), 2, . APPLICABLE DOCUMENTS 2.1 The following documents of the issue in effect on date of invitation for bids form a part of this specification to the extent specified herein. SPECIFICATIONS Military MIL-H -5 6 06 MIL-P-116 Preservation, Method of MIL-P-18177 Plastic sheet
3、, Laminated, Thermosetting, Hydraulic Fluid, Petroleum Base, Air- . craft, Missile, and Or 147, 3.2.3 Inspection and test equipment and facilities, The supplier shall furnish and maintain all necessary inspection and test equipment and facilities and provide personnel for performing all acceptance t
4、ests specified herein, The test equipment shall be adequate to permit performance of the required accept- ance tests for the pressure. transducer, 3,2,4 Dissimilar metals, Unless suitably protected against electrolytic corrosion, dissimilar metals shall not be used in contact with each other. Dis- s
5、imilar metals are defined in Standard MS33586. 3.2,5 Soldering. All solder connections shall be made in accordance with MIL-STD-440. . 3,2.6 Fungus proof material. Materials that are nutrients for fungi shall . not be used unless necessary. Where used and not hermetically sealed they shall be treate
6、d with a fungicidal agent, 3.3 Performance and product characteristics. 3.3.1 Physical characteristics, The pressure transducer shall conform 3,3; 1.1 to the physical requirements delineated on BuWeps Drawing 2539249. r, Using hydraulic oil per Specification MIL-H-5606, the change in volume required
7、 to pressurize the unit from O to 750 psig shall not exceed O. 030 cubic inches, 3.3.2 Pressure medium. Th; pressure transducer shall meet all require- ments specified herein using any pressure medium as follows: (a) (b) Hydraulic OiI per Specification MIL-H-5606. Sea water at temperatures above 27
8、degrees F. (c) Dry nitrogen. 3.3,3 Electrical requirements. All requirements are to be met the first time a measurement is made, Cycling to condition the unit prior to a test is not acceptable, I 3,3,3.1 Potentiometer, The potentiometer shall: (a) Meet ail requirements with 23 to 33 volts direct cur
9、rent (vdc) or volts root-mean-square (vrms) at 4800 *lo0 cycles per second (cps) steady state over a temperature range of O to 168 degrees F, 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-824.59 (OS) (b) Be capable of withstanding 55 vrms a
10、t 4800 hl00 cps for 5 seconds over a temperature range of O to 168 degrees F each time the unit is energized, (c) Be wirewound type. 3,3,3,1,2 DC resistance, terminal 1 to terminal 3, (see figure 1) shall be 5000 rt250 ohms at 79 degrees F. Temperature coefficient shall be IO, 035 percent per degree
11、 F maximum. 3,3,3,1,3 Impedance between terminal 1 and terminal 3 shall be 5000 I300 ohms at 26 -12 vrms, 4800 I100 cps. 3,3,3.1.4 Resolution shall be O. O to 1, O pound per square inch (psi) over a temperature range of O to 168 degrees F. The potentiometer shall be wound with 600 turns minimum over
12、 its active range, 3.3.3.1.5 Repeatability including incremental hysteresis when cycling over any 20-30 psi range shall not exceed 2, O psi over a temperature range of O to 168 degrees F, This requirement includes resolution and all other conditions with no vibration and the case temperature held co
13、nstant within rt5 degrees F, 3.3,3.1,6 Wiper shall withstand 10 ma dc or rms continuously and meet requirements of 3.3 after removal of the current, 3.3,3,1.7 Noise generated during operation f the potentiometer shall not exceed 300 ohms equivalent noise resistance (see 6,3.14). This requirement sha
14、ll apply with the following simultaneous conditions or any combination thereof: (a) Pressure rate of O. O to 30, O psi per second, (b) (c) Wiper current of 100 h10 microamperes (ua) dc. Noise spectrum; low pass with 50 I5 kilocycles (kc) cutoff with a nominal slope of 6 db per octave beyond 50 kc. (
15、d) (e) Vibration as described in operating vibration schedule of table I. Temperature range of O to 168 degrees F. 3.3.3.1.8 Total error in ratio of outputvoltage (terminals 1 and 2) to applied input voltage (terminals 1 and 3) shall not exceed limits specified in figure 1. This requirement shall ap
16、ply with the following conditions: (a) Load (terminal 1 to 2); greater than 9 megohms, (b) Errors due to nonlinearity, hysteresis, resolution or any other condition except test equipment, (c) Environmental conditions as follows, 4 Provided by IHSNot for ResaleNo reproduction or networking permitted
17、without license from IHS-,-,-. MIL-P-82457 33 797970b 0433734 3 a v P MIL-P-82459 (OS) Figure 1. Potentiometer Characteristics -52 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4 MIL-P-2457 13 9777706 0433735 5 1 1 MIL-P-$24.59 (OS) 1, Temperatur
18、e; 65 to 80 degrees F 2. Vibration; none 3. Altitude; . Normal ground atmospheric 4, Humidity; Room ambient, up to 95 percent pressure 24 to 32 inches mercury (d) Applies for increasing pressure and at O psig and 500 psig. 3,3,3,1,9 The transducer shall not require more than a 2.5 psi adjustment in
19、pressure from the pressure at 79 *3 degrees F required to obtain any voltage ratio when tested in accordance with 4.7, This applies at any temperature in the range from O to 168 degrees F other than specified in 3,3.3.1.8(c)l. 3.3.3.2 Switches. 3.3.3.2.1 Each switch shall close (see 6,3.8) within th
20、e specified range as pressure increases from zero psig or any pressure less than the specified pressure and shall remain closed for pressures greater than the specified range, Each switch shall open (see 6,3.9) within the specified range as pressure de.creases from 750 psig or my pressure above the
21、specified range to 750 psig and shall remain open for pressure less than the specified range including errors due to any condition except test equipment, 3.3.3.2.2 Operating (specified) range at the environmental condition of 3,3,3,1,8 shall be: S1:. 8.9 to 12.5 psig S2: 22.3 to 25.8 psig S3: 42.7 t
22、o 46.3 psig 3.3,3,2,3 Operating (specified) rage at any other temperature in the range from O to 168 degrees F shall be: 7.5 to 14. O psig 21. O to 27.5 psig 3,3.3.2.4 Switch contact resistance shall not exceed 10. O ohms at 3, O +O, 2 S1: S2: S3: 41. O to 48. O psig . ma dc at any pressure greater
23、than the pressure specified in 3,3.3,2.2 and 3,3,3,2,3. 3,3,3.2.5 Each switch shall meet all requirements when switching 5. O (Energized per 4.5.2.8) Operating (Energized per 4.5,2.8) 3.4.2 Shock, The packaged pressure transducer csee 5. i. 1) shall be capable of withstanding the shock of being drop
24、ped on a nonyielding surface from a height of 36 inches. Additionally, the pressure transducer, in the con- dition shown in table II, shall withstand shocks specified in table II. Double Amplitude Acceleration Frequency (in) minimum (g) minimum 1, o 5-60 o. 2 - 5 -17 3. O 17 -40 O, 036 - 40-74 10, o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILP824591966PRESSURETRANSDUCERFORTORPEDOMK46MOD0ANDMOD1MK46MOD0 MOD1 鱼雷 压力传感器 PDF

链接地址:http://www.mydoc123.com/p-980800.html