1、 .- MIurpARY SPECIFICAPION 3 I MEL-o-23560 (os) 2 December 1969 Superseding 30 December 1965 . 1-0-2356OB( WP) .! -. . . . - I. - . -. .I _- . OSCmRA*B, GENERAL SFECIEICATON FOR : 1 -.,. _ .a. - This specification has been approved by the Naval Ordnance Systems Conmiand, Department of the Navy - z .
2、 . - . - .- - - . ._ - - .i . I .- _. .- .- -. i SCOPE : . . 1.1 Scope. This specification covers the requirements for the design and procurement of Oscillographs, NAVORD Drawings 815515, 313 ready nonoperatin;. The oscillograph, when rigidly mounted on its mounting base to a vibration device by nor
3、m1 means shall withstand the. vibration requirements specified in 4.4.1.1 and theresfter shall show no damage and shall meet all performance requirements of this specif ication. 3.5J.2 Vibration; operati%. The oscillograph, when rigidly mounted on its mounting base to a vibretion device by nomal mea
4、ns, shallwith- stand the vibration requirements of 4A.1.2. qp Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL 0-23560( OS) 3.5.2 Shock ? 3.5.2.1 Shock; transportation, storage, and handling, (For Level CI only). The oscillograph, packaged as in S
5、ection 5, shall withstand the rough handling test of MIL-P- and thereafter shall show no damage and shall meet all performance requirements and product characteristics of this specificat5on. 3.5.2.2 Shock; ready nonoperating. The oscillograph, when rigidly mounted on its nountins; base to a shock te
6、sting device by normal means, shall withstand the shock requirements of 4.4.2.2 and thereafter shall show no damage and shall meet all performance requirements of this spec- ification without readjustment or repositioning of components, 3.5.3 Temperature and humidity; nonoperating 3.5.3.1 Low temper
7、ature. The oscillograph shall be capable of with- standing a temperature of minus 65 degrees F for a period of 48 hours without showing any adverse effects. The unit shall then be brought to ambient. temperature and humidiky conditions and shall meet all the per- formnee requirements and product Cha
8、racteristics of this specification. 3.5.3.2 High temperature. The oscillograph shall be capable of with- stal-ding a temperature of plus i65 degrees F with a relative humidity of ?c! to 95 percent for a period of 48 hours. to ambient temperatu= and humidity condit5ons and shall meet all the performa
9、nce requirements and product characteristics of this specification. The unit shall then be brought 3.5.4 Temperature; operating 3.5.4.1 Low temperature. The oscillograph shall be conditioned to a temperature of O degrees F and, while at this temperature, shall function according to specifications wi
10、khout showing any adverse effects. 3.5.h.2 High t.emperature. The oscillograph shall be conditioned to a tmperat-ure OF plus i30 degrees F with a relative humidity of 90 to 95 perem%. to spxifications without showing any adverse effects. While at these test conditions the unit shall function accordi
11、ng 3.5.5 Acceleration. The oscil2ograph, when rigidly mounted on an ac- celeration device, shall withstand an acceleration of i5 plus or minus 2 gs for a period of not less than 0.2 second nor more than i5 seconds in each direction along the three axes defined in 3.3.6, shall function during and aft
12、er acceleration tests and thereafter shall show no damage and shall meet all performance requirements of this spec- ification, The oscillograph 12 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-1-0-23560(:( OS) 3.6 Operating life. The oscillograph s
13、hall be capable of withstanding at least 5QO operation cycles without maintenance, except for lamp re- placement. A cycle is defined as an operating period of 10 minutes plus or minus 1 minute, followed by a rest period of 10 minutes plus or minus 1 minute. 3.6.1 The film magazine shall be capable o
14、f being loaded and unloaded 500 successive times and shall show no damage and shall meet all the per- formance requirements and product characteristics of this specification. 3.7 Cleanug. Prior to and after final assembly, all parts, components, and the assembly shall be thoroughly cleaned of loose,
15、 spattered, or ex- cess solder, metal chips, and other foreign matter. Burrs and sharp edges as well as rosin flash shall be removed. 3.8 WorlananshiE. The equipment including all parts and accessories , shall be constructed and finished in a manner to ensrire compliance with all requirements of thi
16、s specification. Particular attention shall be paid to neatness and thoroughness of soldering, wiring, marking of parts and assemblies, plating, riveting, machine screw assenblies, welding, brazing, and freedom of parts from burrs and sharp edges. The standards of workmnship exhibited in any approve
17、d first article sample, subject to any qualification stated in the Governments notice of approval, shall be determinative of the requirements of the contract relative to workmanship insofar as not specifically covered by applicable specifications. 4. QUALITY ASSURANCE PFOVISIONS 4 1 Responsibility f
18、or inspection. Unless otherwise specified in the contract or purchase order, the supplier is responsible for the per- f ormance of all inspection requirements as specif i therefore, there shall be no sampling for acceptance. Defective units shall be rejected. 4.4 First article and periodic productio
19、n inspection. The first article and periodic production samples, after satisfactorily passing the quality conformance inspections detailed in 4.5, shall be subjected to the fol- lowing tests and examinations. results of first article and periodic production inspections shall be forwarded to the Nava
20、lrdnance Systems Command, Certified inspection data covering the 4.4.1 Vibration. The oscillograph, mounted as specified in 3.5.1, shall be subjected to the vibration testing specified herein. 4.4.1.1 Vibration; ready nonoperating. The oscillograph shall be sub- jected to the v5bration testing speci
21、fied in Schedule I in each of the test axes defined in 3.3.6, and thereafter shall show no damage and shall meet all perforniance requirements and product characteristics of this specification. Schedule I Minimum Test Duration Room - Frequency Range Amplitude Temperature -20F +130“F 10 - 30 cps 0.06
22、0 k0.006 in. 60 min. 15 min. i5 min. 31 - 60 CPS 3g +-0.3g 60 min. i5 min. 15 min. 61 - 100 CS 3g +-0.3g 60 min. 15 min. i5 min. The frequency shallbe continuously varied, between each of the limits given, at a uniform rate over a three to four minute period for the duration of the test. As an alter
23、nate method the oscillograph shall be vibrated at specific frequencies differing by not more than five cps in each of the test axes and covering the entire frequency range and amplitudes of Schedule I. The total test time shall be not less than that of Schedule I and the test times at the specific f
24、requencies shall be equally divided. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-flIL-0-23560C 13 477770b 0303457 7 KIL-O-OC (OS) 4.4.1.2 Vibration, opemting. The oscillograph, rigidly mounted on its mounting base to a vibration device, shall be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILO23560C1969OSCILLOGRAPHSGENERALSPECIFICATIONFOR 示波器 通用 规则 PDF

链接地址:http://www.mydoc123.com/p-980508.html