1、 MIL-J-L7LILb 57 7777706 0037573 3 MILITARY SPECIFICATION JUNCTION BOX MARK 41 MOD O -07-/5- MIL- J-19416 ( NOrU 6 April 1956 ISSUED IN LIEU OF NAVORD OS 5418 r/ 1. SCOPE 1.1 This specification governs the manufacture,. assembly and preparation for delivery of Junction Box Mark 41 Mod O and the meth
2、ods of inspection and tests upon which product acceptance will be based. 2. APPLICABLE DOCUMENTS 2.1 The following specifications, standards, drawings and publications, of the issue in effect on the date of invitation for bids, form a part of this document: SPECIFICATIONS MIL-R-25018. - Relays, Mini
3、aturized, Hermetically sealed, airborne equipment NAVY DEPARTMENT General Specifications for Inspection of Material STANDARDS MILITARY MIL-STD-129 - Marking for Shipment and Storage DRAWINGS BUREAU OF ORDNANCE LD 295581 - Junction Box Mark 41 Mod O LD 413162 - Packaging Assembly List for Component L
4、D 412909 - Packaging Assembly List for Component Container Mark 20 Mod O Container Mark 10 Mod O - 1/ When publications, etc. , refer to NAVORD OS 5418., this specification applies. i THIS DOCUMENT CONTAINS /b PAGES , - I -. . - Provided by IHSNot for ResaleNo reproduction or networking permitted wi
5、thout license from IHS-,-,-MIL-J-1941b 59 7797906 0017572 3 W PUB LICATIONS BUREAU OF ORDNANCE OP 400 - General instructions for the Design, Manufacture and inspection of Naval Ordnance Equipment (Copies of specifications, standards, drawings, and publications required by contractors in connection w
6、ith specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer. ) 3. REQUIREMENTS 3.1 General. - The Junction Box Mark 41 Mod O shall be manufactured, assembled and prepared for delivery in accordance with the requirements of documents lis
7、ted on LD 295581. 3.1.1 in Bureau of Ordnance publication OP 400 shall be complied with, as applicable . The general requirements and procedures established 3.2 Continuity 3.2.1 Continuity, sub-assemblies. - All circuits connected by diagram on the cable assembly and receptacle assembly (Drawings 13
8、79501 and 1379500 of LD 295581) shall have a resistance of O. 1 ohm or less with a current of one (1) ampere flowing. This requirement on the receptacle assembly shall be met when the assembly and plug housing are mounted to the junction box body. 3.2.2 Continuity, junction box. - All circuits conne
9、cted by diagram (Drawing 1262262 of LD 295581) shall have resistance values given in the schedule in 4.3.1.2 when a current of one (1) ampere is flowing. indicate a resistance value within this document when tested in accordance with 4.3.2. 3.3 Resistance. - All resistors in the junction box shall 3
10、.4 insulation resistance. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-J-19LILb 57 7797906 0037573 5 -, MIL- J- 194 16 (-Nord 3.4.1 insulation resistance, sub-assemblies. - All pins on connector shells of the cable assembly and receptacle asse
11、mblv shall . indicate an insulation resistance of 50 megohms-or more with respect to every other non-connected pin shorted to all other non-connected pins and connector shells. This requirement on the receptacle assembly shall be met when the assembly and plug housing are mounted to the junction box
12、 body. 3.4.2 insulation resistance, junction box. - All pins on P1, J1, 52, and 53 not connected by diagram (Drawing 1262262 of LD 295581) shall indicate an insulation resistance of 50 megohms or mor when tested in accordance with 4. 3. 3. 3. 5 Capacitor. - Capacitor-Cl (Drawing 1262262 of LD 295581
13、) shall indicate a capacitance value of I. O f O. 2 microfarad when tested in accordance with 4.3.4.1. insulation resistance of this capacitor shall be 50 megohms or greater when tested in accordance with 4.3.4.2. 3.6 Relay 3.6.1 Acceptance tests. - Acceptance tests shall be performed at the discret
14、ion of the Government either at the place of manufacture by the contractor under Government supervision ir by an agency and at a place to be designated by the Government. The acceptance test shall consist of Group A and Group B Acceptance Tests of MIL-R-25018 as detailed in 4. 3. 5.1 of this documen
15、t. These tests shall be run prior to acceptance of each lot of relays for assembly in Junction Box Mark 41 Mod O. Drawing 1262292 shall be used in lieu of a Military Standard for the relay. 3.6.2 Assembly tests. 3.6.2.1 At the applicable stage of Junction Box Mark 41 Mod O assembly each relay shall
16、be tested in accordance with 4. 3. 5.2.1 3. 6.2. 2 Following the completion of the tests of 3. 6.2.1 the following requirements shall be met. 3. 6.2.2.1 The relay (K-1) shall operate with the application of 26. 5 * 2 volts in accordance with 4.3. 5.2.2 of this document. 3.6.2.2.2 Circuits completed
17、through relay contacts shall have a resistance of not more than O. 2 ohm, and open contacts shall show an insulation resistance of 50 megohms or more with the relay energized or de-energized, Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.7 Mechan
18、ical requirements 3.7.1 Case strength. - The cable hook (refer to Drawing 1362936 of LD 295581) shall withstand a shearing force of 1000 pounds without causing fracture or deformity of the case, when tested in accordance with 4.3.6.1. 3.7.2 Plug housing. - The application of 35 pound-inches torque t
19、o the plug housing shall provide 160 degree rotation of this housing with respect to the case. The application of 18 pound-inches or less torque shall not cause rotation of the plug housing from its closed position. 3.8 Durability. - The junction box shall withstand extremes of shock and vibration.
20、After being subjected to these environmental conditions the junction box shall meet all the requirements of 3.2 through3. 7.2 excluding 3. 6.1. 3.8.1 Shock. - The junction box shall withstand shocks simulating careless handling during transportation as specified in 4. 3.7.1. 3. 8.2 Transportation vi
21、bration. - The junction box shall withstand simulated transportation vibrations as specified in 4.3.7.2. 3.8.3 Aircraft vibration. - The junction box shall withstand simulated aircraft vibrations as specified in 4. 3. 7. 3. 3.9 Wor kmans hip 3.9.1 Cleanliness. - Necessary precautions shall be taken
22、to protect the junction box components from moisture, solder splashes, chips, and other foreign matter during assembly processes. 3.9.2 Soldering. - Where soldering is employed, only non-corrosive and non-volatile fluxes shall be used. Rosin shall be used when soldering wires to coils, contacts, or
23、terminals. Solder shall not be used primarily for obtaining mechanical strength; el ectrical connections shall be mechanically secure and electrically continuous before soldering. Sufficient heat shall be applied during the soldering process to avoid ffcoldf solder joints. 4. QUALITY ASSURANCE PROVI
24、SIONS AND TEST REQUIREMENTS 4.1 Preproduction sample. - At the start of pilot production(or prior to full production, if there is no pilot production) a preproduction sample of five (5) Junction Boxes Mark 41 Mod O shall be delivered by the contractor to the Government inspector. These junction boxe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILJ194161956JUNCTIONBOXMARK41MOD0MARK41MOD0 接线 PDF

链接地址:http://www.mydoc123.com/p-980094.html