1、MIL-I-8974AAMENDMENT 202 April 2001SUPERSEDINGAMENDMENT 102 May 1988MILITARY SPECIFICATIONINDICATOR, EVENT COUNTING, GENERAL SPECIFICATION FORThis amendment forms a part of MIL-I-8974A, dated 15 July 1981, and is approved foruse by all Departments and Agencies of the Department of Defense.PAGE 1Dele
2、te 2.1 and substitute with the following paragraphs:“2.1 Government documents .2.1.1 Specifications and standards . The following specifications and standards form a partof this specification to the extent specified herein. Unless otherwise specified, the issues of thesedocuments shall be those list
3、ed in the issue of the Department of Defense Index of Specificationsand Standards ( DoDISS) and supplement thereto, cited in the solicitation.”At the bottom of page to the left of “FSC 6620” add the following:“AMSC N/ADISTRIBUTION STATEMENT A . Approved for public release; distribution is unlimited.
4、”PAGE 2Under SPECIFICATIONS, MILITARY delete the following:“MIL-I-8 974/1 Indicator, Events, Miniature, Digital, 28 VDC”AMSC N/A 1 of 4 FSC 6620DISTRIBUTION STATEMENT A . Approved for public release; distribution is unlimited .INACTIVE FOR NEW DESIGN AFTER 30 AUGUST 1999INCH-POUNDProvided by IHSNot
5、for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-I-8974AAMENDMENT 22Directly above 3. REQUIREMENTS, add the following:“2.3 Order of precedence . In the event of a conflict between the text of this specificationand the references cited herein (except for MS standards
6、 and specification sheets), the text of thisspecification shall take precedence. Nothing in this specification, however, shall supersedeapplicable laws and regulations unless a specific exemption has been obtained.”* 3.2: Delete and substitute:“3.2 First article . When specified (see 6.2), a sample
7、shall be subjected to first articleinspection in accordance with 4.3.”PAGE 5Delete 3 .8.3 and substitute the following:“3.8.3 Filling medium . The filling medium shall be of at least 98 percent purity and free ofdust particles. The filling medium may not contain more than .006 milligram of water vap
8、or (dewpoint 65 C or 85 F maximum) at the filling pressure. The filling medium shall consist of 100percent helium (preferred), a mixture of 88 to 92 percent nitrogen and the remainder helium, or amixture of inert noble gases (such as argon and helium). The absolute pressure of the fillingmedium in t
9、he case shall be a minimum of one atmosphere.”PAGE 8Delete 4.1 and substitute with the following two paragraphs:“4.1 Responsibility for inspection . Unless otherwise specified in the contract or purchaseorder, the contractor is responsible for the performance of all inspection requirements as specif
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILI8974A22001INDICATOREVENTCOUNTINGGENERALSPECIFICATIONFOR 事件 指示器 一般 规范 PDF

链接地址:http://www.mydoc123.com/p-980092.html