NAVY MIL-I-85352-1980 INFLATOR ASSEMBLY AND GAGE ELEMENTS PNEUMATIC PRESSURE REMOTE CONTROL DIRECT READING《直板遥控气压的充气组件及压力计元件》.pdf
《NAVY MIL-I-85352-1980 INFLATOR ASSEMBLY AND GAGE ELEMENTS PNEUMATIC PRESSURE REMOTE CONTROL DIRECT READING《直板遥控气压的充气组件及压力计元件》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-I-85352-1980 INFLATOR ASSEMBLY AND GAGE ELEMENTS PNEUMATIC PRESSURE REMOTE CONTROL DIRECT READING《直板遥控气压的充气组件及压力计元件》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、12 May 1980 SUPERSEDING 2 July 1976 Class B made by subjecting the inflator assemblies to the pressures specified The test shall be 21 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-1-85352 47 m 7797706 0257793 7 m MIL-1-8 53 5 2 herein to produ
2、ce these readings, first with the pressure increasing, then with the pressure decreasing. With the pressures increasing, the pressure shall be brought to, but shall not exceed, the pressure specified to give the desired reading; and with the pressure decreasing, the pressure shall be brought down to
3、, but shall not fall below, the pressure specified to give the desired reading. Accuracy of Size 1 gages at each reading shall be within +6 psig. reading shall be within T2 psig from 10 to 80 psig and +4 psi from 81 to 150 psig. The inflator assembly test shall be conducted on a test set- up as show
4、n on Figure 8. The receiver test gage, shown in this test Set-up, shall conform to the specifications of ANSI B40.1-1974 for test gages. It shall have a pressure range of not more than 750 psi, and shall be graduated in increments not larger than 2 psig. Accuracy of Size 2 gages at each 4.6.3 Overpr
5、essure. With the relief valve removed and its attachment point plugged to prevent leakage, the inflator assembly with lever depressed shall be subjected to a pressure of 3000 psig. lever shall be released and the inflator assembly shall be subjected to the above test pressure for a period of 10 minu
6、tes. and remote controller assembly shall show no sign of leakage or rupture. Not less than 5 minutes following the application of the specified pressure, the inflator assembly shall be subjected to the test of 4.6.2. No calibration or repair of the gaging elements shall be permitted. If the accurac
7、y exceeds the tolerance specified, the gaging elements shall be rejected. The The gage element This test shall be performed with both size gage elements. 4.6.4 Endurance. The inflator assembly and dual chuck stem gage shall be subjected to 10,000 applications of pressure from O to 80 + 5 percent of
8、full-scale pressure and return to O at the rate of 10 + 5cpm. The applied pressure with respect to time shall approximate a sine wave shape. inflator assembly and dual chuck stem gage element shall be subjected to the test of 4.6.2. No recalibration or repair of the gaging elements shall be permitte
9、d. If the accuracy exceeds the tolerance specified, the gaging elements shall be rejected. Not more than 5 minutes following this test, the 4.6.4.1 Functional test. The inflator assembly functional test shall be conducted on the test Set-up shown in Figure 8. Pneumatic pressure to the remote-control
10、ler shall be regulated to 1500 psi. The inflator valve shall be slowly depressed to allow gas to flow into the receiver. There shall be absolutely no indication of pressure on the gage element as the inflator valve lever is depressed. indicator must remain absolutely stationary while gas is flowing
11、into the receiver. lever shall be slowly released. The valve shall instantly stop the flow of gas to the receiver. The gage element indicator shall indicate the pressure in the receiver to within - +6 psi for the Size 1 gage The gage element At the end of a 5 second interval, the inflator valve 22 P
12、rovided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-W 3 % a (3 I W rn O 2 x ow 0-I w oz 3 rn u) W u: Q Co aJ k 3 23 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-M*IL-I-5352 47 W 777770b 0257773 2 W MIL-
13、1-85352 element, and +2 psig from 10 to 80 psig and +4 psig from 81 to 150 psig for the Size 7 gage element without overshoot. shall be slowly depressed and released a total of 4 times to bring the receiver pressure up to the gage element capacity. source pressure being introduced at the gage elemen
14、t or delay in the valve instantly shutting off the flow of the source gas shall be cause for rejection. The inflator valve lever Any evidence of the 4.6.4.2 Relief valve test. The relief valve test shall be conducted on the test Set-up shown in Figure 8 with source pressure regulated to 1500 psi. 10
15、0 psi. until the relief valve opens, inflation. setting by more than 5%. reduce receiver pressure to 85% of relief valve setting. valve shall reseat and exhibit zero leakage. repeated or a total of four times for this and for relief valve settings of 200, 350, 500 and 650 psi. The relief valve shall
16、 be adjusted to vent at The relief valve shall prevent over- The test gage reading shall not exceed the relief valve The bleed-off petcock shall be opened to The inflator lever shall be depressed to pressurize the receiver The relief The above tests shall be 4.6.5 Drop test. The inflator assembly an
17、d dual chuck stem gage shall be dropped at least 25 times from a height of not less than 4 feet on a concrete floor, The inflator assembly and dual chuck stem gage shall strike the floor in various attitudes, i.e. the valve pressure gage, chuck etc. shall hit the floor rather than the hose. The lens
18、 of the pressure gage shall not be chipped or cracked and the gage performance shall not be impaired. shall be subjected to the test specified in 4.6.2. repair of the gage elements shall be permitted. the tolerance specified, the gage element shall be rejected. After the drop test, the gage elements
19、 No recalibration or If the accuracy exceeds 4.6.6 Cold test. Gage elements shall be subjected to a Not cold temperature environment of -2OOF for not less than 6 hours. more than 3 minutes after removal from the cold temperature environment, the gage elements shall be subjected to the test specified
20、 in 4.6.2. No recalibration or repair of the gage elements shall be permitted. If the accuracy exceeds the tolerance specified, the gage elements shall be rejected. - 4.6.7 Heat test, Gag$ elements shall be subjected to a Not heat temperature environment of 140 F for not less than 6 hours. more than
21、 3 minutes after removal from the hot temperature environment the gage elements shall be subjected to the test specified in 4.6.2. recalibration or repair of the gaging elements shall be permitted. If rej ected. No . the accuracy exceeds the tolerance specified, the gage elements shall be 24 Provide
22、d by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-4.6.8 Friction test, Gage elements shall be tested for inherent friction on the test Set-up as shown in Figure 8. shall be tested at no less than four points over the scale range. Size 1, the pressure in the r
23、eceiver shall be brought up to approximately 110 psi by depressing the inflator valve on the remote-controller. lever shall be released and the bleed-off petcock shall be opened to allow pressure in the receiver to bleed down at not less than 10 nor more than 20 psi per minute. The bleed-off petcock
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILI853521980INFLATORASSEMBLYANDGAGEELEMENTSPNEUMATICPRESSUREREMOTECONTROLDIRECTREADING 遥控 气压 充气

链接地址:http://www.mydoc123.com/p-980048.html