1、MIL-IL22129C 15 May 1962 SUPERSEDING 23 February 1961 MIL-I-22129B(SHEPS) MILlTARY SPECIFICATION INSULATION TUBING, ELECTRICAL, POLYTETRAFLUOROETHYLENE RESIN, NONRIGID This specification has been approved by the apartment of Defense and is man- datory for use by the Departments of the Army, the Navy
2、, and the Air Force. 1, SCOPE l. 1 This specification covers nonrigid polytetrafluoroethylene resin tubing for electrical insulating pur- poses. 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids, form a part of this specification to the extent
3、 specified herein: I. . SPECIFICATIONS FEDERAL VV-1-530 - Insulating Oil, Electrical (fpr Transformers, Switches, and Circuit Breakers). STANDARDS MILITARY MIL-STD-104 - Limits for Electrical Insulation Color. MIL-STD-105 - Sampling Procedures and Tables for Inspection by Attributes. (Copies of spec
4、ifications, standards, drawings, and publications required by contractors in connection with specific procurement functions should be obtained from the procuring activity or as directed by the con- tracting officer .) 2.2 Other publications. - The following documents form a part of this specificatio
5、n to the extent specified herein. Unless oaerwise indicated, the issue in effect on date of invitation for bids shall apply. AMERICAN SOCIETY FOR TESTING MATERIALS STANDARDS. D876 - Methods of Testing Nonrigid Vinyl Chloride Polymer Tubing (Tentative) - 60T. D1675 - Testing Electrical Grade Polytetr
6、afluoethylene Tubing mentative) 59T. (Application for copies should be addressed to the American Society for Testing Materials, 1916 Race Street, Philadelphis 3, Pa.) OFFICIAL CLASSIFICATION COMMFTTEE Uniform Freight Classification Rules. (Application for copies should be addressed to the Official C
7、lassification Committee, 1 Park Avenue at 33rd Street, New York 16, N.Y.) S REQUIREMENTS 3.1 Material. - The tubing shall be made of polytetrafluoroethylene resin. S. 1.1 Uniformity. - All tubing in each lot shall be uniform in texture, color, and finish. THIS DOCUMENT CONTAINS 6 PAGES. Provided by
8、IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-“ -“ “. 3.1.2 Defects. - The tubing shall be clean, smooth, and free from foreign material (except pigments when colored), and from imperfections detrimental to fabrication, appearance, or performance of parts, 3.1
9、.3 Color. - Unless otherwise specified (see 6.2), the tubing shall be natural in coldr. Natural tubing can vary from a water white to a straw yellow and range in transparency from translucent to opaque. Colored tubing shall conform to Standard MIL-STD-104. 3.2 Property values.- The tubing shall conf
10、orm to the property values specified in table I. 3.3 Dimensions and tolerances. - 3.3.1 Lengths. - Unless otherwise specified, the footage of tubing on a reel or in a coil shall conform to table II (see 6.2). 33.2 Inside diameters and wall thicknesses. - Unless otherwise specified, tubing shall be f
11、urnished in the standard inside diameters and wall thicknesses shown in table III as specified (see 6.2). 3.3.3 Concentricity. - The minimum percent concentricity of the tubing, whendetermined as specified in 4.5.2, shall be 70 percent. .- 3.4 Workmanship. - The material shall be manufactured and pr
12、ocessed in a careful and workmanlike manner, in accordance with good practice. Table I - Property values for tubing. -0PertY to be tested reference Test Value Nominal Conditioning Unit of value procedure required Inch wall thick- io% I .o20 17,000 11,500 14,600 16,300 Dielectric breakdown: . .016 Vo
13、lts (min.) C-96/23/0 4.5.3 Dielectric breakdown All thick- Percent of dry C-96/23/96 4.5.3 Dielectric Breakdownl All thick- Variability 30 nesses Percent(max.) C-96/23/0 4.5.3 value obtained nesses ontest (min.) 85 Lengthwise shrinkage Stress at 200 percent 1 - Percent(max.) E-2/300 4.5.4 elongation
14、/ 4.5.5 C-96/23/50 P.8.i. (max.) - - Each of the five specimens shall elongate at least 200 percent; otherwise, the material shall be con- #or thickness not shown, the dielectric breakdown shall be that given for the nearest thickness shown. 2,500 “- P.s.i. (min.) 6,000 . e sidered as failing to con
15、form to the specification. Table II - Tubing lengths. Minimum length coil reel Minimum length AWG size number in feet per in feet per 30 to 22, inclusive 20 to 17, inclusive 1 , O00 li; -“ 10 to O, incltlsive 200 16 to 11; inclusive 500 -“ -“ “he shortest piece in the coil shall not be less than 3 f
16、eet in length. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-1-22121, 4. QUALITY ASSURANCE PROVISIONS 4.1 Unless otherwise specified in the contract or purchase order, the supplier is responsible for th performance of all inspection requirement
17、s a8 specified herein. The Government reserves the right to per- form any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2 Sampling for acceptance inspection. - 4.2.1 E,- A lot of tub
18、ing shall consist of all tubing of the same size offered for delivery at the same time. 4.2.2 Sampling for visual and dimensional examination. - Sample reels or coils of tubing shall be se- lected in accordance with Standard MIL-STD-105 at inspection level II from each lot for the visual and dimensi
19、onal examination specified in 4.3.1. Table III - Inside diameters and wall thicknesses of tubing (AWG sizes). AWG size number 30 28 26 24 22 20 19 18 17 16 . 15 14 13 12 11 10 9 8 8 7 6 5 4 3 2 2 1 O T Inside diameter (inches) I Wall thickness (inches) 0.010 .O13 .O16 .o20 ,025 .O39 .O43 .O40 .; 045
20、 .O51 .057 .o64 .O72 .o81 . .o91 .lo2 .114 I120 .129 .144 .162 .182 .204 .250 .289 i229 258 Minimum Minimum Maximum .325 I .347 .O16 0.015 . o19 .o22 .O27 ,032 . O40 . O44 .O49 .O54 .o61 .O67 .O74 .O82 .O91 .lo1 .112 ,124 .130 -141 .158 .178 ,198 .224 .249 .260 .278 ,311 0.007 .o07 ,007 ;o10 .o10 ,0
21、13 .O13 .O13 .O13 .O13 .O13 .O13 ,013 .O13 .O16 ,016 .O16 .O16 .O16 .O16 .O16 .O16 .O16 .O16 .O16 013 ,013 0.011 .Oll .o11 .O14 ,014 . o19 . o19 . o19 o19 . o19 . o19 . o19 . o19 . O19 . o19 . O19 .O24 .O24 .O24 .O24 .O24 .O24 .O24 .O24 .O24 .O24 024 0.009 . O09 .o09 .o12 012 .O16 .O16 .O16 .O16 .O1
22、6 .O16 .O16 .O16 .O16 .O16 016 .o20 020 .o20 . 020 .o20 .o20 .o20 .o20 .o20 .o20 .o20 4.2.3 Sampling for acceptance tests. - Three sample reels or coils shall be selected from each lot for tests a8 specified in 4.3.2. The mnimum quantity taken from each sample reel or coil shall be 32 feet. Y 4.3 Ac
23、ceptance inspection. - 4.3.1 Visual and dimensional examination. - Each sample selected in accordance with 4-2.2 shall be visually and dimensionally examined to verify conformance with the requirements in 3.1, 3.3 and 3.4. Any reel or coil having one or more defects shall be rejected, It the number
24、of defective samples exceeds the acceptable number for the appropriate sampling plan of Standard MIL;-STD-105 at acceptance quality level (AQL) 2.5 percent, the lot represented by the samples shall be rejected. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license fr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILI22129C1962INSULATIONTUBINGELECTRICALPOLYTETRAFLUOROETHYLENERESINNONRIGID 带电 聚四氟乙烯 树脂 绝缘 管道 系统

链接地址:http://www.mydoc123.com/p-979749.html