1、. MIL-G-82432 4444906 L48580L 5T3 = I INCH-POUND I MIL-G-82932(OS) 23 June 1994 MILITARY SPECIFICATION GAS GENERATOR, M17, REMANUFACIWRED ASSEMBLY This specification is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by ail Departments and Agencies
2、 of the Department of Defense. 1. SCOPE 1.1 Scope. This specification covers the requirements for the remanufacture and acceptance of the M17 Gas Generator, referred to herein as “gas generator.“ 2. APPLICABLE DOCUMENTS 2.1- Government documents. 2.1.1 Specifications and standards. The following spe
3、cifications and standards form part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those listed in the issue of the Department of Defense Index of Specifications and Standards (DODISS) and supplement thereto, cited in the solicitation (
4、6.2). SPECIFICATIONS MILITARY MIL-V-173 Varnish, Moisture and Fungus Resistant MIL-C-5501 Caps and Plugs, Protective, Dust and Moisture Seal MIL-C-5604 Compass; Magnetic, Pilots Standby MIL-C- 16555 Coating Compound, Strippable, Sprayable MIL-G-60624 Generator, Gas Pressure, Propellant Actuated, XM
5、17, Assembly Beneficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Commander, Indian Head Division, Naval Surface Warfare Center, Standardization Branch (Code 8420), 101 Strauss Avenue, Indian Head, M
6、D 20640-5035 by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document, or by sending a letter. AMSC NIA FSC 1377 DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or ne
7、tworking permitted without license from IHS-,-,-MIL-G-82932 997790b 1985802 43T STANDARDS MILITARY MIL-STD-105 Sampling Procedures and Tables for Inspection by Attributes MIL-STD-129 Marking for Shipment and Storage- Ammunition and Explosives MIL-STD- 17 1 Finishing of Metal and Wood Surfaces MIL-ST
8、D-4 13 Visual Inspection Guide for Elastomeric O-rings MIL-STD-453 Inspection, Radiographic MIL-STD-1168 Ammunition Lot Numbering MS295 13 Packing, Preformed, Hydrocarbon Fuel Resistant, O-ring MS5 1965 MS5 1966 Setscrew-Hexagon Socket, Fiat Point, Alloy Steel, Cadmium Plated, UNC-3A, Plain and Self
9、-Locking Setscrew-Hexagon Socket, Fiat Point, Alloy Steel, Cadmium Plated, UNF-3A, Plain and Self-Locking (Unless otherwise indicated, copies of Federal and Military specifications and standards are available from: Standardization Documents Order desk, Bldg. 4D, 700 Robbins Avenue, Philadelphia, PA
10、191 11-5094.) 2.1.2 Other Government documents, drawings, and publications. The following other Government documents, drawings, and publications form a part of this document to the extent specified herein, Unless otherwise specified, the issues are those cited in the solicitation (see 6.2). DRAWINGS
11、 NAVAL SURFACE WARFARE CENTER, INDIAN HEAD DIVISION (CAGE CODE 19200) 8593297 Cap, Shipping 8593745 Cartridge, Impulse, M37, Assembly 8864324 8864325 Box, Packing, Ammunition, for Generator, Gas Pressure, Propellant Actuated: M17, In Fiber Container M510 Container, Ammunition, Fiber, M510 for Genera
12、tor, Gas Pressure, Propellant Actuated: M17, In Fiber Container M510 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-9242372 MIL-G-82932 9999906 1985803 376 Carton, Alternative Packing, Ammunition, for Generator, Gas Pressure, Propellant Actuated:
13、M17, In Fiber Container M510 10520494 Lubricant 10521864 Label, Identification 10522490 Generator, Gas Pressure, Propellant Actuated, M17 Assembly 1052249 1 Label, Warning 10522492 Generator, Gas Pressure, Propellant Actuated, M17, Metal Parts Assembly 10522493 Cap, Initiator 10522494 Pin, Firing 10
14、522495 Pin, Shear 10522496 Body, Chamber 10522497 Cap, Shipping CODE OF FEDERAL REGULATIONS (CFR) 49 CFR 100-199 Transportation (Application for copies should be addressed to the Superintendent of Documents, U.S. Government Printing Ofice, Washington, DC 20402.) 2.2 Order of precedence. In the event
15、 of a conflict between the text of this document and the references cited herein, the text of this document takes precedence. Nothing in this document, however supersedes applicable laws and regulations unless a specific exemption has been obtained. 3. REQUIREMENTS 3.1 General. Materials, components
16、, and assemblies shall comply with the requirements of Drawing 10522492 and all referenced specifications and procedures unless otherwise specified herein. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-G-82932 = Ob L985804 202 MIL-G-S2932(OS)
17、 3.1.1 New components or materials. During gas generator remanufacture, the following previous installed components or materials shall be discarded following disassembly and replaced with new components or materials which conform to cited documents: Comiionent or material Document Ouantitv a. Coatin
18、g, Compound b. Cartridge, M37, Impulse c. Cap, Shipping d. Cap, Shipping e. Compound, Thread f. DC-33 Lubricant g. Label, Identification h. Label, Warning i. O-ring j. O-ring k. Pellet, Nylon I. Pin, Shear m. Setscrew n. Setscrew o. Varnish MIL-C-16555, TYPE II 8593745 8593297 10522497 10522490, Not
19、e 10 10520494 1052 1864 1052249 1 MS295 13- 12 MS295 13-20 10522496, Note 9 10522495 MS51965-133 MS51966-110 MIL-V-173 AIR 1 Each 1 Each 1 Each AIR AIR 1 Each 1 Each 1 Each 1 Each 2 Each 1 Each 1 Each 2 Each AIR 3.1.2 Reusable item. The following previous assembled components may be suitable for reu
20、se, when components meet cited documents and inspection requirements: Components Document uantity a. Body, Chamber b. Cap, Initiator c. Pin, Firing 10522496 10522493 10522494 1 Each 1 Each 1 Each 3.2 Primary Components. For the purpose of this specification, the M37 Impulse Cartridge (Drawing 859374
21、5) is defined as a primary component. Only one lot of primary components shall be used in each lot of gas generators, although, a primary component lot may be used in more than one gas generator lot. The gas generator lot shall contain only one M37 Impulse Cartridge lot manufactured and accepted wit
22、hin 12 months of completed gas generator lot assemblies. 3.3 Gas generator production. The gas generators shall be remanufactured in accordance with this specification, the documents listed herein and as described in specification MIL-G-60624. Each production gas generator or component, as applicabl
23、e, shall meet the requirements of 3.3.1 through 3.3.2.4, respectively. Failure of any component or gas generator to meet the applicable requirements of 3.3 shall result in rejection of that unit. 4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.3.
24、1 Gas generator caps and chambers (Drawings 10522493 and 10522496). 3.3.1.1 Protective finish. For any gas generator cap or chamber having a nonconforming exterior protective finish, the existing finish shall be stripped from the part. Following the stripping operation, a finish meeting 1.1.2.2 of M
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILG829321994GASGENERATORM17REMANUFACTUREDASSEMBLYM17 改造 组装 毒瓦斯 发电机 PDF

链接地址:http://www.mydoc123.com/p-979403.html