1、-.- MI L-G-8 1 737A (AS) 24 August 1984 SUPERSEDING MIL-G-81737(AS) 14 August 1969 MI LI TARY SPEC1 FI CATION GELLING UNITS, FUEL MARK 1, NOD O AND MOD 1 This Specification is approved for use by the Naval Air Systems Command, Department of the Navy, and is available for use by all Departments and A
2、gencies of the Department of Defense- 1. SCOPE 1.1 Scope. This document covers the minimum requirements for electrically powered, mechanical gelling units used for the production of gelled fuel for fire bombs. vol tage (220/440) capabi 1 i ties. Specified in the contract or purchase order (see 6.2):
3、 AT1 gelling units covered by this document have complete dual 1.2 Classification. Units shaT1 be wired to the following types as Type I - 220 volts, 60 hertz (Hi!), 3 phase Type II - 440 volts, 60 Hz, 3 phase 2. APPLICABLE DOCUMENTS 2.1 Government documents. 2.1.1 Specifications, standards, and han
4、dbooks. Unless otherwise specified, the following specifications, standards, and handbooks of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DODISSI specified in the solicitation form a part of this specification to the extent specified herein. Ben
5、eficial comments (recommendations, additions, deletions) and any pertinent data which may be of use in improving this document should be addressed to: Engineering Specifications and Standards Department (Code 93), Naval Air Engineering Center, Lakehurst, NJ 08733 by using the self-addressed Standard
6、ization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or by letter. FSC 1040 7- . THIS DOCUMENT CONTAINS - j3- PAGES Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-SPEC1 FICATIONS F ED ERAL QQ-S-781 PPP-B-60 1 PP
7、P-B-6 36 PPP-T-97 MILITARY MIL-P-116 MI L-G-5572 MIL-H-83282 MIL-G-1737A LO m 7777906 0357779 T -* MI L-T-5624 STANDARDS MILITARY MIL-STD-129 MI L-STD- 1 43 MI L-STD-81 O MI L-STD-889 MI L-G-817 37A (AS) Strapping, Steel, and Seals Boxes, Wood, C1 eated-P1 ywood Boxes, Shipping, Fiberboard Tape, Pre
8、ssure-Sensi tive Adhesive, Fi 1amentReinforced Preservation, Methods of Gasoline, Aviation, Grades 80/87, 100/130, 115/145 Hydraulic Fluid, Fire Resistant, Synthetic Hydrocarbon Base, Aircraft, NATO Code Number H-537 Turbine Fuel, Aviation, Grades JP-4 and JP-5 Marking for Shipment and Storage Stand
9、ards and Specifi cations, Order of Precedence for the Selection of Environmental Test Methods and Engineering Guidelines Di ss imi 1 ar Metal s 2.1.2 Other Government documents, drawings, and publ ications. The fol lowing other Government documents, drawings, and publ i cations form a part of this s
10、pecification to the extent specified herein. NAVAL AIR SYSTEMS COMMAND (Code Ident 30003) AS-1 532-1 Gel Component ( Non-Al ka1 i ne), Fi re Bomb (Solution A) AS-1 533 NAVA1 R 1 Gel Component (Al ka1 i ne), Fire Bomb (Solution BI 9-1-112 Gelling Unit, Fuel, Mark 1, Mod O Operational Maintenance and
11、Ove.rhau1 Instructions with IPB DL2581 669 Gelling Unit, Fuel, Mark 1 Mod O DLl558AS100 Gelling Unit, Fuel, Mark 1 Mod 1 e Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-NIL-G-81737A LO m 777970b 0357775 1 m L MIL-G-81737A(AS (Copies of specificatio
12、ns, standards, handbooks, drawings, and pub1 ications required by manufacturers in connection with specific acquisition functions should be obtained from the contracting activity or as directed by the contracting officer.) specification to the extent specified herein. 2.2 Other publications. The fol
13、lowing documents form a part of this AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM) ASTW 01655-83 Turbine Fuels, Specification for (Application for copies of ASTM publications should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) UNIFORM
14、 CLASSIFICATION COMMITTEE, Agent Uniform Frei ght C1 assi f i cat i on Ru1 es (Application for copies should be addressed to the Uniform Classification 2.3 Order of precedence. In the event of a conflict between the text of Committee, Room 1106, 222 South Riverside Plaza, Chicago, IL 60606.) this sp
15、ecification and the references cited herein, the text of this- specification shall take precedence. . 3. REQUIREMENTS 3.1 First article. When specified, a sample shall be subjected to first 3.2 Selection of specifications and standards. Specifications and O article inspection (see 4.4 and 6.3). stan
16、dards for necessary commodities and services not specified herein shall be selected in accordance with MIL-STD-143. 3.3 Materials. Materials shall conform to applicable specifications and drawings, and shall be as specified herein. Materials which are not covered by specifications, or which are not
17、specifically described herein, shall be of the best quality, of the lightest practical weight, and suitable for the purpose intended. 3.3.1 Metal parts. All metal parts shall be of corrosion resistant material or treated in a manner to render them adequately resistant to corrosion. 3.3.1.1 Dissimila
18、r metals. Unless suitably protected against electrolytic corrosion, dissimilar metals shall not be used in intimate contact with each other. Dissimilar metals are defined in MIL-STD-889. 3.4 Design and construction. unit shall be in accordance with the applicable drawings listed on DL2581669 and the
19、 Mod 1 unit shalt be in accordance with the applicable drawings listed on DLl558ASl0, and the requirements listed herein. The design and construction of the Mod O e 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.5 Performance. 3.5.1 Wiring and r
20、otation. The motor shall rotate in a counterclockwise e direction as viewed from the fan end when the unit is examined in accordance with 4.6.2 through 4.6.2.2, with assignment of voltage as specified by the procuring activity (see 6.2). 3.5.2 Gel mobility. The average flow of the gelled fuel produc
21、ed by the unit shall not exceed 4 inches in 60 21 seconds when tested in accordance with 4.6.3 through 4.6.3.3. 3.5.3 Blending. The unit shall blend the gelling agents in the ratios of 4.8 to 5.04 volumes of Solution A (see 6.4) and 2.42 to 2.54 volumes of Solution i3 (see 6.4) per 100 volumes of fu
22、el in accordance with 4.6.4 through 4.6.4.2.1. 3.5.4 Capacity. The unit shall deliver gelled fuel at a minimum rate of 35 gallons per minute (gpm) from the gel-discharge hose when operated in accordance with instructions given in 4.6.4 through 4.6.4.2.2 with a suction head of 6 21 feet for solutions
23、 and fuel. 3.5.5 Leakage. There shall be no gage indicated pressure drop and no external leakage from any joint, shaft seal, or mating surface of the unit when subjected to 150 25 pounds per square inch gage (psig) pressure in accordance with the testing procedures specified in 4.6.5 through 4.6.5.1
24、. 3.5.6 Pressure switch requirements. The pressure switch shall automatically shut down the unit within 20 seconds after the supply of Solution A is depleted. Functioning shall be tested in accordance with 4 3.5.7 Temperature switch. The temperature switch shall automati cal ly down the unit when th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILG81737A1984GELLINGUNITSFUELMARK1MOD0ANDMOD1MOD0 燃料 标志 单位 PDF

链接地址:http://www.mydoc123.com/p-979382.html