1、I +op a/. MIL-F-7872C (ASG) 18 NOVEMBER 1966 Superseding MIL-D-7872B(Wep) 12 June 1962 MIED-7006A(ASG) 6 January 1956 MILITARY SPECIFICATION FIRE AND OVERHEAT WARNING SYSTEMS , CONTINUOUS , AIRCRAFT: TEST AND INSTALLATION OF This specification has been approved by the Department of the Air Force and
2、 by the- Naval Air Systems Command. 1. SCOPE 1.1 Scope. This specification describes the-requirements for the design, manu- facture, testing and installation of - continuous. type fire and overheat warning systems for use in aircraft. These systems employ continuous lengths of heat- sensing elements
3、 connected to a monitoring device. 2. APPLICABLE DOCUMENTS 2.1 The following documents, of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein: SPECIFICATIONS Federal TT-S-735 Standard Test Fluids; Hydrocarbon M
4、ilitary MIL-P-116 MIL-D-1000 MIL-W-5088 MIL-E5272 MIL-E-5400 MIED-6055 MIL-R-6106 1-1-6181 MIL-E-7080 MIL-L-7808 Preservation, Methods of Drawings, Engineering-and Associated Lists Wiring, Aircraft, Installation of Environmental. Testing, Aeronautical and Associated . Equipment, General Specificatio
5、n for Electronic Equipment, Aircraft, General Specificat ion for Drums, Metal, Reusable, Shipping and Storage (Cap. from 88 to 510 Cubic Inches) Relay, Electric, Aerospace, Genera1 Specification for Interference Control Requirements, Aircraft Equipment Electric Equipment , Piloted Aircraft, Installa
6、tion Lubricating Oil, Aircraft Turbine Engine, Synthetic and Selection of, General Specification for Base . Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-P-7936 - MIL-1-8700 MIL-W-25038 . 1-26482 STANDARD3 Military MIL-STD-130 MIL-STD-143 MIL-S
7、TD-411 MIL-STD-704 W25231 Parts- and Equipment, Aeronautical, Preparation for Delivery Installation and Test of Electronic Equipment in Aircraft, General Specification for Wire, Electrical, High Temperature and Fire Resistant, Aircraft Connectors, Electric, Circular, Miniature , Quick Disconnect Ide
8、ntification Marking of US Military Property Specifications and Standards, Order of Precedence Aircrew Station Visual Signals Electric Power, Aircraft, Characteristics and Lamp , Incandescent, Single Contact , Miniature Metals , Definition of Dissimilar for the Selection of Utilization of Bayonet Bas
9、e, T-3-1/4 Bulb When requesting any of the applicable documents, refer to both title and number. All requests should be made via the cognizant Government inspector. Copies of this specification and-other unclassified specifications and drawings required by contractors in connection with specific pro
10、curement functions should be obtained upon application to the Commanding Officer, Naval Supply Depot. (Code CDS) , 5801 Tabor Avenue, Philadelphia, Pennsylvania lgl2O. All other documents should be obtained froni the procuring activity or as directed by the contracting officer. 1 3. REQUIREMENTS 3.1
11、 Preproduction testing. This specification makes provision for preproduction testing (see 4.3). 3.2 Components. The fire warning system shall consist of lengths of sensing elements, connectors, flexible connections, clamps, interconnecting wiring, relays, control unit, warning signals and test switc
12、hes, as required. 3.2.1 Nomenclature. The term “control unit“ as used in this specification shall include any device used to monitor the sensing element circuit and to actuate a warn- ing device on the instrument panel. The term “sensing element“ shall include any heat sensor used in the fire warnin
13、g system. The tem “system“ shall refer to the fire warning system. 3.3 Design objective. Items of this specification which are identified as “design objectives are intended as guides. Approval by the procuring activity is not required for deviations from such objectives. The contractor shall furnish
14、 evidence to the procuring activity or the Government inspector that due consideration has been given to meeting these objectives. 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-3.4 Materials and parts. 3.4.1 Metals. Metals shall be of a corrosion
15、 resisting type, or shall be protected to withstand aircraft fuels, lubricating oils, salt. spray, prolonged high humidity and atmospheric conditions for the life of the equipment when in storage and in service use. Dissimilar metals, as defined in MS33586, shall not be used in intimate contact with
16、 each other. 3.4.1.1 Magnesium. The use of magnesilun and its alloys shall be avoided if practic- able, and its use where necessary shall be subject to approval by the procuring activity. 3.4.2 Nonmetals. All nonmetals shall be moisture- andflame-resistant to the extent, practicable commensurate wit
17、h other aircraft design requirements, shall not support fungus growth, and shall. not be adversely affected by weathering, aircraft fluids and temperature extremes encountered during operation or storage of the aircraft. 3.b.3 Select.ion of materials and parts. Specifications and standards for neces
18、sary materials and parts, processes and equipment which are not specifically designated herein shall be selected in accordance with the order of precedence set forth in MIL-STD-143. AN or MIL standard parts shall be used wherever they are suitable fc.r t.he purpose. 3.4.3.1 Materials. Materials shal
19、l conform to the applicable specifications as set forth in MIL-E-5400. 3.k.4 Interchangeability. All parts having the same manufacturers part number sha.11 be directly and completely interchangeable with each other with respect. to installation and performance. Changes in manufacturers part numbers
20、shall be gov- erned by the drawing number requirements of MIL-D-1000, t 3.4.5 Weight. Weight shall be kept to a minimi consistent with other requiremects of tns specif-ication. 3.5 System design requirements. 3.5.1 Fire response. The system shall indicate a fire within. 5 seconds after any 6-inch po
21、rtion of the entire sensing element arrangement is exposed to a 2,000 F flame of the flame test burner illustrated on figure 1. The systems shall maintain . the fire signal for the duration of the fire and shall automatically clear the signal in not more than 30 seconds following extinguishment of t
22、he fire. As-a design objec-. tive, the system should also be capable of indicating a fire within 5 seconds after any 6-inch portion of the entire sensing element arrangement is exposed to a 1,500 F flame. 3.5.1.1 Automatic repeatability. The system shall be capable of signalling three consecutive fi
23、res without requiring manual resetting. 3.5.2 Loop circuit. Detachable sensing. elements -shall be connected to the control unit in a- continuous loop circuit such that a single break in the sensing element. loop will not cause the system to become inoperative. If one or more breaks occur, those por
24、tions of the sensing element circuit that remain connected-to the control unit shall retain the ability to detect and signal a fire. 3 v Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UBES ISGATED AT INTERSECTION F SOLID LINES DOTS LOCATE SECONDARY
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILF7872C1966FIREANDOVERHEATWARNINGSYSTEMSCONTINUOUSAIRCRAFTTESTANDINSTALLATIONOF 安装 测试 飞机 连续 消防

链接地址:http://www.mydoc123.com/p-979192.html