NAVY MIL-F-18680 C-1985 FLY TENT FIRE WATER WEATHER AND MILDEW RESISTANT《抗水火苍蝇及霉菌的帐篷》.pdf
《NAVY MIL-F-18680 C-1985 FLY TENT FIRE WATER WEATHER AND MILDEW RESISTANT《抗水火苍蝇及霉菌的帐篷》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-F-18680 C-1985 FLY TENT FIRE WATER WEATHER AND MILDEW RESISTANT《抗水火苍蝇及霉菌的帐篷》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-F-LbOC 83 = 777770b 03L306 4 = e- 23- 40 SUPERSEDING MIL-F-l868OB(MC) 22 September 1970 MILITARY SPECIFICATION FLY, TENT: FIRE, WATER, WEATHER, AM) MILDEW RESISTANT This specification is approved for use by U. S. Marine Corps, Department of the Navy, and is available for use by all Departments a
2、nd Agencies of the Department of Defense. 1.1 scope. This specification covers requirements for one type and size of tent fly having the followirq dimensions: Length of sides - 20 feet 7 inches width when laid - 25 feet out flat 2. APPLICABLE IXXIUMENTS 2.1 Govemnt documents. 2.1.1 Specifications, s
3、tandards, and handbooks. Unless otherwise specified, the following specifications, standards, and handbooks of the issue listed in that issue of the Department of Defense Index of Specifications and Standards (DODISS) specified in the solicitation form a part of this specification to the extent spec
4、ified herein. SPECIFICATIONS FEDERAI, Tq-8 7 1 4-285 Q-S-781 ccc-c-4 29 CCC-C-4 67 DDD-L-20 - Twine, Fibrous Cotton, Wrapping. - Thread, Polyester. - Strapping, Steel and Seals. - Cloth, Osnaburg, Cotton. - Cloth, Burlap, Jute (Or Kenaf). - Label; For Clothing, Equipage, And Tentage (General Use). B
5、eneficial commrnts (reoommendations, additions, deletions) and any pertinent data which my be of use in improving this docunent should be addressed to Commandant of the Marine Corps, Headquarters, U, S. Marine Corps (Code LNA-l), Washington, DC 20380, by usir-g the self-addressed Standardization Doc
6、ument Improvement Proposal (DD Form 1426), appearing at the end of this document, or by letter. Y FSC 8340 THIS DOCUMENT CONTAINS 3 PAGES. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-F-LbBOC 3 m 977770b 0383307 b m MILITARY MIL-L-I 709 MIL-S-
7、1734 MIL-G-16491 MIL-C-43627 STANDARDS FEDERAL, FED-STD-75 1 MILITARY MIL-STD-105 MIL-STD-I 29 MIL-STD-147 DRAWING Marine Corps P-196 - Line, Tent. - Slip, Tent Line. - Gramiet, Metallic. - Cloth, Duck, Cotton, Plied Yams, Fire, Water, Weather and Mildew Resistant Treated, Light Dry Finish. - Stitch
8、es, Seams, And Stitchinqs. - Sampling Procedures And Tables For Inspection By - Marking For Shipnt And Storage. - Pallet ized Unit Loads. Attributes. - Fly, Tent; Fire, Water, Weather And Mildew Fes istant . (Copies of specifications, standards, handbooks, drawings, and publications required by manu
9、facturers in connection with specific acquisition functions should be obtained frm the contracting activity or as directed by the contracting officer.) 2.2 Other publications. The follawing documents form a part of this specification to the extent specified herein. The issues of the documents which
10、are indicated as DoD adopted shall be the issue listed in the current DoDISS and the supplement thereto, if applicable. .- UNIFORM CLASSIFICATION COMMITIEE Uniform.Ftreight Classification Rules (Application for copies should be addressed to the Uniform Classification Committee, Room 1106, 222 South
11、Riverside Plaza, Chicago, Illinois 60606.) NATIONAL MYIDR FREIGHT TRAFFIC ASSOCIATION, INC., AGENT National mtor Freight Classification (Application for copies should be addressed to the American Trucking Association Inc., Tariff Order Section, 1616 P Street, N. W., Washinqton, D. C. 20036.) 2 Provi
12、ded by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- -_ VIL-F-18hOC 83 = 9997906 0381308 8 2.3 Order of precedence. In the event of a conflict between the text of this specification and the references cited herein, the text of this 1 specification shall take
13、precedence. i , 3. REQUIRFMENTS 3.1 Guide samples. The guide samples are furnished solely for guidance and information to the contractor (see 6.3). Variation from the specification my appear in the sample, in which case the specification shall govern. 3.2 First article. Unless otherwise specified (s
14、ee 6.2) , before production is cwrmienced, a finished fly tent shall be submitted, or made available to the contracting officer or his authorized representative for approval. The approval of the first article authorizes the- mmencement of production, but does not relieve the contractor of responsibi
15、lity for carpliance with applicable provisions of the specification. “he first article shall be manufactured by the supplier in the same facilities to be used for the manufacture of the production items. 3.3 Materials. 3.3.1 Cloth, cotton, duck. The cloth, before finishing, shall be 9.85 ounce per q
16、uare yard, anforming to MIL-C-43627. The cotton duck shall be dyed Olive drab 7. 3.3.2 Thread, polyester. The thread shall conform to type I or type II, class 1, subclass B, size E, of V-T-285. The thread shall be dyed Olive drab shade S-1 (Cable No. 66022). The dyed thread shall show good fastness
17、to weathering. 3.3.3 Line, tent. The rope for the lines shall be manila or sisal, 1 inch circumference, 11 feet 6 inches long, conformincl to type XIX, clws A for manila rope or class B for sisal rope of MIL-L-1709. In lieu of stitching or serging the end of the lines with thread or twine in order t
18、o prevent raveling, the end may be bound with brass wire or may be finished with rust- resistant wire clips. 3.3.4 Slips, tent line. The tent line slips shall conform to type II of MIL-S-1734. 3.3.5 Gromnets and washers. Grcmniets and washers shall be brass, black oxide finish, rolled rim grmunet, s
19、pur washer, conforming to type III, class 3, No. 4 and No. 7 of MIL-G-16491. Grommets and washers for the side edges of the fly shall be No. 4, and for the back and front edges shall be No. 7, as shown in Drawing No. P-196. The design an construction shall conform to 3.4 Design and construction. . D
20、rawing No. P-196 and the following. 3.4.1 Stitches, seams, and stitching. The stitch, seam and stitching types specified herein shall conform to FED-STD-751. Ail anels shall be ioined with stitch type 301 or type 401 as follows. The Sem forming h FWMR. The letters “U. S.“ shall be applied on the upp
21、er side of the fly in $-inch high block letters, in the locations sham in Drawing No. P-196 and shall conform to the reauiremnts for type IV, class 9 labels of DDD-L-20. Fastness of the class 9 labels shall be as specified for class 6 labels. 3.7 Workmanship. The finished flies shall conform to the
22、quality and grade Occurrence of defects shall not of product established by this specification. exceed the applicable quality levels (PQL). 4. QUALITY ASSURANCE PROVISIONS 4.1 Bspnsibility for inspection. Unless otherwise specified in the contract or purchase order, the contractor is responsible for
23、 the performance of all inspection requirements as specified herein. Except as otherwise specified in contract or purchase order, the contractor may use his own or any other facilities suitable for the performance of the inspection requirements specified herein, unless disapproved by the Government.
24、 Ihe Government reserves the right to perform any of the inspections set forth in the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.1.1 ertificate of burrs or sharp edges which may damage the item or cause injury in ha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILF18680C1985FLYTENTFIREWATERWEATHERANDMILDEWRESISTANT 水火 苍蝇 霉菌 帐篷 PDF

链接地址:http://www.mydoc123.com/p-979100.html